Fushiman D260 type differential pressure valve for steam

Manufacturer:  Fushiman Co.,LTD.
Model: D260

ModelNominal diameterPrimary pressure measurementDifferential pressure setting rangeMaximum operating temperatureBody MaterialConnection
D26015–80Max. 1.0 MPa0.03 to 0.8 MPa220°CFC, FCDFlanges
  • The D260 differential pressure valve is used in boiler combustion lines, etc.
    The primary valve is the P260 pressure reducing valve. For detailed specifications of the primary valve, please refer to the P260 pressure reducing valve (page 6 and beyond).

  • Specifications and Performance

ItemSpecification
Nominal Diameter15–80
Main Valve FluidSteam
Detecting FluidGas, Non-Corrosive Liquid
Primary SideMaximum Pressure P₁: 1.0 MPa
Maximum Temperature: 220°C
Secondary Side P₂0.03–0.9 MPa
Detecting Pressure P₃1.0 MPa or lower
Differential Pressure Setting Range (ΔP = P₂ – P₃)0.03–0.2 MPa, 0.1–0.8 MPa
Cv Value4.5d² → 3.1d²
Minimum Pressure Reduction Ratio10% of Primary Side Pressure (Min. 0.07 MPa)
Offset0.03 MPa or lower
Hysteresis0.02 MPa or lower
Minimum Adjustable Flow Rate5% of Rated Flow
Valve Leakage Rate0.05% or lower of Rated Flow
Valve Body MaterialCast Iron
Main Valve & Main Valve SeatStainless Steel
Piston & CylinderStainless Steel
DiaphragmStainless Steel
Spring GuardBronze
Main Valve & Strainer ConnectionFlange Type, JIS 10K Full Face

Notes:

  1. The main valve performance values are based on a detected pressure P₃ of 0 kPa (atmospheric pressure).
  2. The Cv value is the same as that of the P260 pressure reducing valve (see page 7 for reference).
  3. Offset, shut-off pressure rise, and minimum adjustable flow rate are reference values (target values).
  4. For nominal diameters 15 to 40, the valve body is made of spheroidal graphite cast iron.

Structure and Dimensions

D260

Dimensions

Nominal Diameter (mm)L (mm)H₁ (mm)H₂ (mm)K (mm)Weight (kg)
15145781751308
20150731801308.5
251607118213010
321757719313112
401908520312614
502109521712618
6523511123612626
8026512325312632

Installation Example

The nominal diameter selection for the D260 differential pressure valve, piping examples, and alarm safety valve nominal diameter selection are the same as those for the P260 pressure reducing valve (pages 7 and 9). Please refer to them.

REQUEST QUOTATION