ModelNominal diameterFluidMaximum Operating PressureMaximum Operating TemperatureBody MaterialConnection
RK86

15 to 200

Steam
Gas
Liquid
4.0 MPa300°CMartensitic stainless steel (equivalent to SUS420)Wafer

Wafer type, compact, and lightweight — installation orientation is optional.

Specifications

ModelRK86-RK86A
DescriptionThe maximum operating pressure and temperature vary depending on the flange standard.
Metal seat types exceeding 300°C can also be manufactured.
Type of Disc Contact SurfaceMetal SeatSoft Seat
Applicable FluidLiquid, gas, and steamWater, condensate, and steamMineral oilGas and air
Maximum Operating Pressure (MPa)4.03.33.02.64.03.33.24.03.33.1
Maximum Operating Temperature (°C)201002003002010012020100160
MaterialDiscStainless SteelEPDMFluororubber
Body & Seat (Integral)RK86 type (Nominal diameter 15–100): Martensitic stainless steel
RK86 type (Nominal diameter 125–200): Carbon steel
RK86A type (Nominal diameter 15–200): Austenitic stainless steel
SpringStainless steel
Pipe Connection: Compatible FlangesJIS 10K (Nominal diameter 15–100 only)
JIS 16K/20K (All nominal diameters except 50–80)
DIN PN10/16/25/40 (All nominal diameters)
ASME Class 150/300 RF (All nominal diameters)

Structure and Dimensions

ModelRK86-RK86A
Nominal Diameter1520253240506580100125150200
DimensionsL1619222831.54046506090106140
DMin445364738396110158 (132)(1)151194 (216)(2)220 (251)(2)275 (308)(2)
Max67768293104118136186
Opening PressureInstallation OrientationWithout Spring0.250.250.250.350.400.450.500.550.651.251.401.35
With Spring1.001.001.001.201.301.401.501.601.803.503.803.70
0.750.750.750.850.900.951.001.051.152.252.402.35
0.500.500.500.500.500.500.500.500.501.001.001.00
Cv Value4.37.9121827436890135262345597
Weight0.30.40.50.81.11.82.53.45.4111425

Note (¹): Exclusive for JIS 20K. Values in parentheses are for JIS 10K. Nominal diameter 80 is not available in that specification.
Note (²): Values in parentheses are for ASME Class 300 RF.
Remark: The allowable tolerance for opening pressure is ±20%. Do not use for pressure regulation purposes.

Pressure LossRK86

Note (³): Do not use under partial opening conditions (when pressure loss ΔP is 2 kPa or 5 kPa or less), as chattering may occur.

  • The graph shows data for water at 20°C.
  • To determine the pressure loss for other fluids, read the graph using the equivalent flow rate calculated as follows:
      Vw = V × ρ / 1000
      Vw: Equivalent flow rate (ℓ/s or m³/h)
      ρ: Fluid density (operating) (kg/m³)
      V: Actual flow rate (operating) (ℓ/s or m³/h)
  • The graph is based on horizontal piping.
  • For vertical piping, there may be slight differences before the valve is fully open. Once fully open (normal flow condition), it is the same as for horizontal piping.