Fushiman RPF12 type lift type safety relief valve

Manufacturer:  Fushiman Co.,LTD.
Model: RPF12

ModelNominal diameterfluidSet pressureMaximum operating temperatureBody MaterialConnection
RPF1215〜80Steam/Gas/Liquid0.02 to 1.6 MPa220℃FC,FCDflange

Features

  • The pop-up mechanism enables instant operation.
  • A spring suitable for the operating pressure is used, ensuring a high discharge capacity and stable operation.
  • It can be used as a highly reliable device for various pressure vessels, measuring instruments, and pressure piping systems to handle abnormal pressure increases.

RPF12

Specifications and Materials

ShapeOpen Type with LeverSealed Type without Lever
FluidSteam, AirSteam, Air, and Non-Corrosive Gas/LiquidWater, Hot Water
PressureSet Pressure: 0.02–1.6 MPa (Back Pressure: Atmospheric Pressure)
Operating Temperature0~220℃0~220℃0~Saturation Temperature
Maximum Usable Viscosity20 mPa·s (at the operating temperature of the liquid)
MaterialsValve BodyCast Iron (For 15A–40A JIS16K, Spheroidal Graphite Cast Iron)
Valve SeatStainless SteelStainless Steel with Stellite Weld Overlay
Valve DiscStainless SteelStainless Steel with Stellite Weld Overlay
Valve StemStainless Steel
Spring Protection TubeCast Iron
Adjustment SpringSpring Steel, Piano Wire
LeverCast Iron
CoverCast Iron
Adjustment RingBrass, Bronze
ApplicationPressure vessels, headers, secondary side of pressure reducing valves, thermal relief, and other piping protection
Applicable StandardsPressure Vessel Structural Standards

Dimensions and Mass

Nominal DiameterFace-to-Face DimensionWith LeverWithout LeverPipe Connection: Flange StandardMass
LH1H2H2InletOutlet
15X 157368165136JIS 10K Full FaceJIS 10K Full Face4.2
20 x 2075701651364.5
25 X 2585851771486.7
32 X 3295902011729.5
40 X 401009522019111.2
50 x 5011010527623816.0
65 x 6513012033628626.0
80 x 8014013539334333.5
15X 207583172143JIS 16K Full FaceJIS 16K Full Face4.7
20 x 2575851721435.4
25 X 3290901871587.5
32 x 40959521218310.0
40 X 5010010523520613.0
50 X 6511511528825017.6
65 X 8013013035330327.3
80X10014514540835838.7

RPF12 Type・RPF13 Type Saturated Steam Discharge Capacity (According to Pressure Vessel Structure Regulations)

Nominal Diameter15-20253240506580
Seat Bore Diameter D (mm)21263341516681
Lift l (mm)0.60.70.91.11.31.72.1
Blowout Area A (mm²)/Set Pressure (MPa·G)Coefficient CSet Pressure (MPa·G)39.557.193.3141.6208.2352.4534.3
0.11.000405895144212359544
0.21.0005884138209308522791
0.31.000781131852824147011064
0.41.003991432343555228841340
0.50.99911817128042562610591606
0.60.99513819932649572912341871
0.70.99115722837256583114072133
0.80.98717625541763493215782393
0.90.985196283463704103517522656
1.00.983215311509773113719252919
1.10.980234339554841123720953177
1.20.978254367600910133922663436
1.30.976273394645979143924373695
1.40.9752924226901048154126093957
1.50.9743114507361117164327824218
1.60.9733314787821186174529534478
1.70.9723505068271255184631254738
1.80.9713695348721324194732964998
1.90.9703885619171393204834675257
2.00.9704085909641463215136415521

RPF12 Type・RPF13 Type・RPS16 Type・RPS17 Type Air Discharge Capacity (According to Pressure Vessel Structure Regulations, at 20°C)

Nominal Diameter15-20253240506580
Seat Bore Diameter D (mm)21263341516681
Lift l (mm)0.60.70.91.11.31.72.1
Blowout Area A (mm²)/Set Pressure (MPa·G)39.557.193.3141.6208.2352.4534.3
0.16594153233343581881
0.2941372233394998451282
0.312718430045667111361723
0.415923137757384314272163
0.5192278454690101417172604
0.6225325531807118620083045
0.7257372608923135822993486
0.82904196851040153025903926
0.93224667621157170128804367
1.03555138391274187331714808
1.13885609161391204534625249
1.24206089931507221737525690
1.345365510701624238840436130
1.448570211471741256043346571
1.551874912241858273246257012
1.655079613011975290449157453
1.758384313782092307652067893
1.861689014552208324754978334
1.964893715322325341957878775
2.068198416092442359160789216

RPF12 Type・RPF13 Type・RPS16 Type・RPS17 Type Air Discharge Capacity (According to High-Pressure Gas Safety Act, at 20°C)

Nominal Diameter15-20253240506580
Seat Bore Diameter D (mm)21263341516681
Lift l (mm)0.60.70.91.11.31.72.1
Set Pressure (MPa·G)/Blowout Area A (mm²)0.3950.5710.9331.4162.0823.5245.343
0.16189145221324550833
0.2931352213364958381270
0.312618229845266511261707
0.415822937456883514142144
0.5190275450684100517022581
0.6223322527799117619903018
0.7255369603915134622783454
0.82874156791031151625663891
0.93204627551147168628544328
1.03525098321262185631434765
1.13845559081378202734315202
1.24166029841494219737195639
1.344964910601610236740076075
1.448169611371726253742956512
1.551374212131841270845836949
1.654678912891957287848717386
1.757883613662073304851597823
1.861088214422189321854478260
1.964292915182304338857368696
2.067597615942420355960249133

RPF12 Type・RPF13 Type Water Discharge Capacity (According to General Discharge Capacity Calculation Formula)

Nominal Diameter15-20253240506580
Seat Bore Diameter D (mm)21263341516681
Lift l (mm)0.60.70.91.11.31.72.1
Set Pressure (MPa·G)/Blowout Area A (mm²)39.557.193.3141.6208.2352.4534.3
0.1134919503186483671101203518248
0.21907275745066839100561702025806
0.32336337755198376123162084631606
0.42698390063729672142212407136496
0.530164360712510813159002691240803
0.633044776780511845174172948144698
0.735695159843012795188133184348279
0.838155515901213678201123404151613
0.940475850955914508213323610654744
1.0426661661007615293224863805957705
1.1447464671056816039235833991760522
1.2467367551103816752246324169263213
1.3486470311148917436256384339565794
1.4504772961192218095266054503368278
1.5522475521234118730275394661370674
1.6539678001274519344284424814272992
1.7556280401313819939293184962475238
1.8572382731351920517301685106277420
1.9588085001388921080309945246179541
2.0603387211425021627318005382481607

Notes:

  1. The discharge capacity calculation formula is based on the vent well calculation formula in the High-Pressure Gas Safety Act.
  2. This table applies to cases where the back pressure of the discharge outlet is atmospheric pressure and the overpressure is 25%.
  3. If G ≠ 1, multiply the values in the table by the G value to obtain the required discharge capacity.