Fushiman RVD19-2 type vacuum breaker

Manufacturer:  Fushiman Co.,LTD.
Model: RVD19-2

ModelNominal diameterFluidMaximum Operating PressureMaximum Operating TemperatureBody MaterialConnection
RVD19-2

20-50

water1.0 MPa90°CCAC406Screw in

This is a basic vacuum breaker with over 20 years of proven performance. It operates reliably with a simple structure.
If the piping or container becomes vacuumed and left as is, it may cause backflow or result in the container being crushed.
The RVD19-2 model quickly draws in air to break the vacuum when the piping or container is vacuumed.
Note: A check valve can be installed upstream of the RVD19-2 model to prevent backflow.

Features

Breaks vacuum quickly with a large suction volume.
Operates reliably with a very small pressure difference due to its diaphragm shape.
Maintains stable operation even under long-term pressure (up to 1 MPa) and temperature (up to 90°C).
All wetted parts are made of corrosion-resistant materials, so there is no concern about rust.
The valve body uses synthetic rubber, providing excellent sealing performance.

Specifications / Performance

FluidCold and hot water
Nominal diameter20・50
Max operating pressure (MPa)1
Max operating temperature (°C)90
Min operating pressure (kPa)−1.5 or lower
Valve bodyBronze
Diaphragm valve bodySynthetic rubber
StrainerStainless steel
Pipe connectionThreaded type JIS Rc
ApplicationVacuum breaking for cold/hot water piping in refrigerators, hot water appliances, pools, bathrooms, dishwashers, medical equipment, etc.
Also prevents negative pressure damage in air piping systems.

Structure / Dimensions / Weight

Nominal Diameter2050
Dimensionsd¾2
H80109
A108140
Weight1.54

Air Intake Volume

Usage Example

If a vacuum breaker is not installed in the diagram and, for some reason, valve A is closed, while a hose is submerged in a bucket at point B and water is drawn from a water fountain or another outlet at point C, the supply pipe may fall into negative pressure.
This can cause a reverse siphon effect, sucking water from the bucket into the drinking water system, leading to contamination.
However, if an RVD19-2 model is installed as shown in the diagram, when valve A is closed and negative pressure occurs near point B, the RVD19-2 quickly draws in air, preventing water from the bucket from being sucked into the system.

Precautions for Use

  1. Do not raise the downstream piping of the vacuum breaker.
  2. The vacuum breaker alone does not have a backflow prevention function. If used for backflow prevention, raise the pipe by at least 150 mm above the vacuum breaker as shown in the diagram, and install a check valve upstream of the vacuum breaker.
  3. Install it in a clean location and do not insulate the air intake opening.
  4. To prevent unexpected water leakage from the air intake, install it in a safe and drainable location.

Note:
If the water supply tank, etc., is filled above the inlet level, or if there is a risk of the water surface being higher than the tank, install a check valve and vacuum breaker to prevent backflow.
Also, install RVD19-2 where there is a risk of siphoning due to a sudden pressure drop.