Hishiko
Hishiko KEGFA Series Electro Permanent Magnetic Chuck

Manufacturer: Hishiko Co., Ltd.
Model: KEGFA Series
Electro Permanent Magnetic Chuck For Grinding
Applications
Most suitable for high precision grinding and slicing.
Features
- As there is no heat generation in the chuck, hence reduction in accuracy on account of thermal displacement is difficult to occur.
- Electro permanent magnetic chuck requires electrical power to switch ON and OFF the magnet for few seconds. During ON, built-in strong permanent magnets hold the workpiece.
- Electric consumption can be reduced. Also it is safe because it can keep holding workpiece even if there is power failure or disconnection of wire during the operation.

Specification (mm)
| Stock No | Model | Poles Width | Pole Pitch | Height | Base Plate | Lead Wire Length(m) | Weight (kg) | Recommended Controller | |||
|---|---|---|---|---|---|---|---|---|---|---|---|
| B1 | L1 | Le | H | B2 | L2 | ||||||
| S904101 | KEGFA150×300 | 150 | 300 | 268 | 14 (12+2) | 85 | 144 | 344 | 2 | 25 | HCC105APS1 |
| S904102 | KEGFA150×350 | 350 | 296 | 394 | 30 | ||||||
| S904103 | KEGFA150×450 | 450 | 408 | 494 | 38 | ||||||
| S904105 | KEGFA200×500 | 200 | 500 | 466 | 16 (14+2) | 190 | 544 | 56 | |||
| S904106 | KEGFA200×600 | 600 | 562 | 644 | 3 | 67 | |||||
※Large or powerful chuck (KEGX type) is also available.
Electro Permanent Magnetic Chuck For Grinding Controller HCC-P
Features
- Adopt the latest power device and microcomputer control.
- By high-speed switching using semiconductor, HCC series achieves excellent neutralization result in a short time.
Because there is no operating noise during neutralization, it is very quiet.

| Stock No | Model | Dimensions (mm) | Input Power Source Voltage | DC Output Rating | Neutralization Duration(Sec.) | Weight(kg) | Note | |||
|---|---|---|---|---|---|---|---|---|---|---|
| Width | Height | Depth | Voltage | Current | ||||||
| S9812520 | HCC105APS1 | 130 | 256 | 151 | AC100V/200V 50/60Hz Single phase | AC100V:DC5~85V AC200V:DC5~100V | 5A(MAX) | 2~19 | 2.5 | Standard Model |
| S9812521 | HCC105APS2 | 130 | 256 | 151 | AC100V/200V 50/60Hz Single phase | AC100V:DC5~85V AC200V:DC5~100V | 5A(MAX) | 2~19 | 2.5 | ・External operation is possible. ・Outputting contact signal to external equipment is possible. |
| S9812523 | HCC185APS1 | 130 | 256 | 151 | AC200V 50/60Hz Single phase | DC5~180V | 5A(MAX) | 2~19 | 約2.5 | Standard Model |
| S9812527 | HCC185APS2 | 130 | 256 | 151 | AC200V 50/60Hz Single phase | DC5~180V | 5A(MAX) | 2~19 | 2.5 | ・External operation is possible. Outputting contact signal to external equipment is possible. |
| S9812458 | HCC1010P | 300 (360) | 400 | 200 (235) | AC100V/200V 50/60Hz Single phase | AC100V:DC5~85V AC200V:DC5~100V | 10A(MAX) | 2~19 | 11 | with Control Box (come with 5m cable) |
| S9812459 | HCC1810P | 300 (360) | 400 | 200 (235) | AC200V 50/60Hz Single phase | DC5~180V | 10A(MAX) | 2~19 | 11 | |
Note: Total electric current of connected chuck(s) must be within 90% of the maximum output current rating of the controller.