ITO CM/ GM/ GMF Range Medium Pressure Regulator

Manufacturer: I.T.O Corporation
Model: CM/ GM/ GMF Range

Incorporated: Strainer*
*CM-100, CM-100A and GMF-70 only.

  • The CM, GM, GMF range is of direct-operated regulators to be used with high inlet pressure up to 1.56MP, and reduce outlet pressure to the range of 0.02~0.30 MPa.
  • The JIS 20K flanged connection for high pressure inlet.
Maximum Flow Rate (Nm³/h)37
InletJIS 20K 15A Flange (RF)
OutletJIS 10K 15A Flange (FF)
Strainer Mesh Gauge110 Mesh
Maximum Flow Rate (Nm³/h)37
InletJIS 20K 15A Flange (RF)
OutletJIS 10K 15A Flange (FF)
Strainer Mesh Gauge110 Mesh
Maximum Flow Rate (Nm³/h)37
InletRc 1/2
OutletRc 1/2
Strainer Mesh Gauge110 Mesh
Maximum Flow Rate (Nm³/h)130
InletJIS 20K 20A Flange (RF)
OutletJIS 10K 20A Flange (FF)
Strainer Mesh Gauge60 Mesh
Maximum Flow Rate (Nm³/h)190
InletJIS 20K 25A Flange (RF)
OutletJIS 10K 25A Flange (FF)
Maximum Flow Rate (Nm³/h)380
InletJIS 20K 25A Flange (RF)
OutletJIS 10K 40A Flange (FF)
Maximum Flow Rate (Nm³/h)580
InletJIS 20K 40A Flange (RF)
OutletJIS 10K 40A Flange (FF)
Maximum Flow Rate (Nm³/h)950
InletJIS 20K 50A Flange (RF)
OutletJIS 10K 50A Flange (FF)
Maximum Flow Rate (Nm³/h)950
InletJIS 20K 50A Flange (RF)
OutletJIS 10K 50A Flange (FF)
Maximum Flow Rate (Nm³/h)1600
InletJIS 20K 80A Flange (RF)
OutletJIS 10K 80A Flange (FF)

Range Specification

Inlet0.10~1.56 MPa
Outlet0.02~0.30 MPa*1
Lockup Pressure (MPa)≤ Set Point × 1.3
(Minimum: Set Point + 0.012)

*1 Interchangeable springs are available.

Interchangeable Spring Selection

No.Set Point Range (MPa)
0.02~0.030.02~0.070.02~0.150.02~0.200.02~0.30
CM-100
GMF-70
No.Set Point Range (MPa)
0.02~0.030.02~0.060.02~0.100.02~0.150.02~0.200.02~0.30
GMF-100~200B1A0A1A1 + B1A2 + B1A2 + B2
GMF-300~500A1A1 + B1
GM-1000A1A1 + B1

     shows the standard spring.