Koganei Bar Type BX01 High-Speed Charge Removal

Manufacturer: KOGANEI CORPORATION

Features

Performance and Advanced Ionization

  • Optimal Balance Systems: To begin with, the high-frequency AC method provides a stable ion balance typically within $\pm$10V.

  • High-Performance Formats: Furthermore, a newly developed AC (200 Hz) format exhibits stable, long-term performance for eliminating static charges.

  • Model Specific Balance: Specifically, the DTY-ELF14H model produces an excellent ion balance of $\pm$5V, whereas the DTY-ELF13H maintains $\pm$10V.

  • Safe Emission Levels: Consequently, the hardware maintains extremely low ozone production levels at less than 0.004 ppm.

Application Versatility and Design

  • Adaptable Configurations: Additionally, the series offers a wide array of nozzle types that enable charge removal ranging from pinpoint targets to wide area workpieces.

  • No-Air Requirements: Therefore, several models require no air supply, which allows for flexible installation based on the location.

  • Advanced Ion Delivery: Moreover, specialized blow type models facilitate pinpoint charge removal and ion transport via tubing and metal piping.

  • Compact All-in-One Solutions: Similarly, the all-in-one unit ionizer features a compact body measuring just $25\text{ mm} \times 35\text{ mm}$ and does not require high-voltage wiring.

  • Resource Optimization: Finally, the air-saving type sucks in outside air for blowing to reduce overall air consumption during the elimination process.

Environmental Integration and Safety

  • Cleanroom Optimization: To support sensitive environments, specialized needles made of special alloys dramatically reduce dust generation.

  • Quiet Operation: Specifically, the built-in cross-flow fan operates at a low noise level of 48dB (A) or less.

  • Integrated Safety Monitoring: Furthermore, the alarm output function detects problems with static discharge, high-voltage circuits, or internal fans.

  • Electrical Protection: Likewise, the system ensures safety by detecting abnormal electrical discharges and overcurrents.

  • Certified Standards: As a result, the hardware remains CE marking compliant to meet industrial safety requirements.

Maintenance and User Interface

  • One-Touch Upkeep: Because of the specialized design, users can remove or attach the discharge needle unit and louvers with one touch and without any tools.

  • Automated Functions: In addition, an automatic cleaning function eliminates the need for manual maintenance of the discharge needle on certain models.

  • Precise Airflow Adjustment: Therefore, a flow rate adjusting knob enables you to obtain the required air flow rate for your specific task.

  • Visual Status Updates: Similarly, integrated balance indicators and LED lamps allow users to confirm the ratio of positive and negative ions at a glance.

Specifications

Item \ ModelDTY-BX01 main unit External potential sensor type
DTY-BX01-200-(L)DTY-BX01-400-(L)DTY-BX01-200-FDTY-BX01-400-F
Input voltage24 VDC ±5%
Consumption current mA110170240410
Output voltage kV±2 (during high frequency operation)
Indicator lamp (LED)①POWER(Power display LED: Green)
②H.V(Discharge display LED: Blue)
③CHECK(Static charge removal display and cleaning timer display LED: Yellow)
④ALARM(Alarm display LED: Red)
Safety circuitAn error is output and the LED on the main unit lights when there is a circuit error or abnormal output.
Input/outputPower supply signal connector (7P)①24 VDC
②0 V
③F.G.
④Check output (Open collector output; 50 mA max at 24 VDC, internal voltage drop 0.3 V max at 5 mA)
⑤Alarm output (Open collector output; 50 mA max at 24 VDC, internal voltage drop 0.3 V max at 5 mA)
⑥Signal output (Open collector output; 50 mA max at 24 VDC, internal voltage drop 0.3 V max at 5 mA)
⑦Discharge stop (H.V off) input (Discharge stop by 0 V; at short circuit, no voltage input, internal drop voltage of 0.5 V or less, input current 5 mA at 24 VDC)
External potential sensor connectors2 ch
Communication interfaceRS232C
Integrated sensorNone
Low particle specificationsNote 1AvailableNone
Ionizer installation distance mm [in]50 [1.97] or over
Static charge removal modeIon polarity control static charge removal mode, pulse static charge removal mode, high-frequency static charge removal mode
Ion balance VWithin ±30
(150 mm [5.91 in] from center of main unit, at 0.1 MPa [15 psi] supply air pressure, during high frequency operation)
Within ±30
(150 mm [5.91 in] from center of main unit, during high frequency operation)
Ozone concentration ppm0.04 or less
(300 mm [11.81 in] from center of main unit, at 0.25 MPa [36 psi] supply air pressure)
0.04 or less
(300 mm [11.81 in] from center of main unit)
Particle generation amountNote 1, Note 2 Particles50 or less
MediumAir (Clean air, water vapor and oil removed)
Operating air pressure range MPa [psi]0.05 to 0.5 [7 to 73]
Expended air flow rate ℓ/min [ft3/min] (ANR)60 [2.12]
(when 0.5 MPa [73 psi] is applied)
100 [3.53]
(when 0.5 MPa [73 psi] is applied)
Fan air volume m3/min [ft3/min]0.09 [3.2] (per fan)
Number of fans installed Fan48
WeightNote 3 g [oz]153 [5.40]275 [9.70]229 [8.08]430 [15.17]
Operating environment0 to 40°C [32 to 104°F] / 65% or less (Non-condensation)
AccessoriesUser manual, brackets (1 set), power signal cableUser manual, brackets (1 set), power signal cable, filter for fan (installed)

REQUEST QUOTATION

PAYMENT

payment-methods

Return Top