Koganei Pressure Switch Module Mpa Gauge

Manufacturer: KOGANEI CORPORATION

Features

The pressure switch module is designed for use with both the FRZ and FRZB Series. However, it is important to note that it cannot be used in combination with the FRZ Series FRZ3_ or RZ3_ models. This distinction ensures proper system functionality and prevents compatibility issues in specific applications.

Specifications

ItemModel
MediaAir
Connection methodSpecifically for FRZ series module installation
Maximum operating pressure1.0 MPa [145 psi]
Proof pressure1.5 MPa [218 psi]
Operating temperature range (atmosphere and media)5 to 60°C [41 to 140°F] (non-condensation)
Pressure setting range0.1 to 0.4 MPa [15 to 58 psi]
Response differential0.08 MPa [12 psi] or less
Contact typeReed contact of “a” contact (NO)
Electrical Specifications
Wiring type2 wire type
Load voltage5 to 28 VDC, 85 to 115 VAC
Load currentDC 40 mA MAX, AC 20 mA MAX
Internal voltage drop0.1 V MAX (at load current of DC 40 mA)
Leakage current0 mA
Response time1 ms MAX
Insulation resistance100 MΩ MIN. (500 VDC Megger, between case and lead wire terminal)
Dielectric strength1500 VAC (50/60 Hz) in 1 minute (between case and lead wire terminal)
Shock resistance294 m/s² (non-repeated)
Vibration resistance88.3 m/s² [9 G] (total amplitude 1.5 mm (0.059 in) 10 to 55 Hz) resonance frequency 2750 ±250 Hz
Lead wiresPCCV 2.0 SQ × 2-wire (brown and blue) × ℓ
Contact protection measureRequired
Mass60 g [2.12] (for wire length A: 1000 mm [39 in])
Mass85 g [3.00] (for wire length A: 1000 mm [39 in])