This design eliminates bubble blending caused by pressurization, and it ensures smoother and more stable liquid flow during operation. As a result, the process maintains higher accuracy and consistent dispensing quality. Moreover, the system significantly reduces the volume of liquid chemicals required during maintenance. Therefore, users lower chemical consumption, cut operating costs, and improve overall efficiency while maintaining reliable performance.
Specifications
| Model | F-EPT10-16W | F-EPT10-18W |
| Dispensing volume | 0.5–10 mL | |
| Maximum dispensing pressure | 0.3 MPa | |
| Dispensing flow rate | 0.1–2 mL/s | |
| Suction flow rate | 0.1–2 mL/s | |
| Maximum viscosity of media | 10000 cP | |
| Repeatability of dispensing volume | ±0.5% F.S. | |
| Proof pressure | 0.4 MPa | |
| Mass | 3.6 kg | |