Japan, KONAN ELECTRIC, Rotary Actuator
KONAN TA2 Series Rotary Actuator With Pneumatic-Pneumatic Positioner Double-Acting Type

Product Made In Japan
Manufacturer: KONAN ELECTRIC
Model: TA2 Series
This type is equipped with a compact electric pneumatic positioner, which precisely controls the rotating angle of the actuator. We provide two options available:CW Type turns clockwise to increment of the signal pressure, and CCW type turns vice versa.
Specifications
| Bore size[mm] | φ 63 | φ 80 | φ 100 | φ 125 | φ 160 |
| Operating fluid | Compressed air | ||||
| Operating pressure | 0.3 〜 0.7MPa | ||||
| Proof pressure | 1.05MPa | ||||
| Operating temperature | -5〜 60℃(In case of 5℃ or less, ensure to be removed any water contained for prevention of freezing.) | ||||
| Output torque | Please refer to the“Table of Output Torque”(P21 〜 P23) (The load torque is recommended not to exceed 50% of the valve in the output torque table.) | ||||
| Rotating angle | 90° | ||||
| Angle adjustment range | ± 5°both end | ||||
Characteristics of the Positioner
| Input signal | 0.02 〜 0.1MPa |
| Cam characteristics | Linear characteristics |
| Linearity | ± 5% F.S |
| Hysteresis | 2% F.S |
| Repeatability | 3% F.S |
| Sensitivity | 3% F.S |
| Seismic capacity | 1% F.S |
| Air consumption | 10L/min〔ANR〕(SUP 0.4MPa, Output pressure 75%) |
| Structure | Dustproof and drip-proof |
| Main component material | Body, Cover: Aluminum |
Model Code

Operating principle

When the input signal is applied to the input chamber (1a), the flapper moves in the arrow A direction around the fulcrum plate spring (2). This movement causes the flapper (3) to be separated from the nozzle (4) the pressure of the nozzle back-pressure chamber (5) to decrease, the balance with the pressure chamber (6) to be lost, and the relay spool (7) to push the port A (8a) to open the air-intake valve seat. At the same time, in port B (8b), the air-intake valve seat of the relay spool (7) is closed and the exhaust valve is opened. Supply pressure is fed from the OUT1. to the right cylinder chamber (14a) and from the OUT2. to the left cylinder chamber (14b) and finally vented to the atmosphere via the exhaust port (13) to lower the stem (15). This movement is transferred to the B lever (16b), A lever (16a), cam (18), zero arm (20) and range arm (21) to extend the feed-back spring (12) and move until the spring tensile strength balances with the output of the input chamber. Accordingly, a change in the opening of the stem (15) in proportion to the input signal pressure is obtained. In balanced conditions at the point indicated by the signal, the respective air-intake valve seat and exhaust valve seat of the OUT1. and OUT2. are returned to the neutral position. In the conditions where loads are not applied to the right and left cylinder chambers, the pressure is set at the balance pressure (approx. 75% of supply pressure).
Characteristics

Dimensions of the Positioner

External Dimensions
〈φ 63・80・100〉

〈φ 125・160〉

- Kouei is Distributor/Agent of KONAN.
- Other items of KONAN.
- Request the quotation for KONAN.