Japan, Krohne
Krohne OPTIFLUX 2300 Electromagnetic Flowmeter
![](https://koueitrading.com/global/wp-content/uploads/2020/06/Screenshot_2024-06-13_142159-removebg-preview-575x380.png)
Made in Japan
Manufacturer: KROHNE Japan KK
Model: OPTIFLUX 2300
Features
- Bi-directional flow measurement over a wide dynamic range (turn down ratio: up to 1000:1)
- No inlet/outlet runs needed for OIML R49 class 1 accuracy
- Widest diameter range available in the market
- Available with patented virtual reference grounding method: cost-saving installation without grounding rings
- PP or hard rubber liner: excellent chemical resistance
- Optional for burial installation and constant flooding (IP68)
- Largest custody transfer approved diameter range
- Tamper proof
- Standard measurement accuracy: ±0.2% or ±1mm/s of measured value (MV)
- Extensive sensor and process diagnostics (incl. NE 107)
- Meets potable water standards: ACS, DVGW, NSF, TZW, KTW, WRAS, KIWA, etc.
- On-site verification of flowmeter with OPTICHECK service tool
Typical Applications
General
- All advanced water and wastewater applications
- Custody transfer measurement
Water and wastewater industry
- Fiscal metering (custody transfer) of potable water
- Abstraction and irrigation
- Monitoring of distribution networks
- Water treatment plants (raw water, drinking water, treatment chemicals)
- Wastewater networks
- Combined and separate sewage systems
- Storm water overflows (SWOs)
- Municipal wastewater treatment plants
- Desalination plants (sea water, permeate, brine)
Iron, metal and steel industry, chemical and other process industries
- Industrial water (process or production water, cooling and boiler feed water etc.)
- Industrial wastewater collection, treatment and return flows, industrial wastewater collection, treatment and return flows, ballast water, injection water, etc.
Specifications
General information
Product Type | Flowmeter |
---|---|
Product Family Name | OPTIFLUX |
Product Positioning | For advanced water, wastewater, and custody transfer (CT) applications |
Measurement Principle | Electromagnetic |
Measured Media | Liquids |
Operating conditions
Process Pressure | max. 40 barg/580 psig |
---|---|
Process Temperature | -5…+90°C/+23…+194°F |
Materials
Liner | Polypropylene (PP), Hard rubber |
Process connections
Flange connections | EN (1092-1): DN25…3000 ASME (B 16.5): 1…120″ JIS (B 2220): 25…1000A |
Approvals/Standards
Certificates/Approvals Custody Transfer (CT) | MI-001, OIML R49 |
---|---|
Certificates/Approvals Ex | ATEX, cQPSus, IECEx, NEPSI, EAC Ex, INMETRO, FM, CSA, KCs, PESO, IA |
Certificates/Approvals Marine | ABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RS |
Certificates/Approvals Potable Water | DVGW, NSF, TZW, KTW, WRAS, KIWA, ACS |
Communication
Analogue Outputs | 4…20 mA |
---|---|
Discrete Outputs | Limit switches, Pulse, Frequency, Status |
Digital Outputs | FOUNDATION™ fieldbus, HART®, Profibus-PA, Profibus-DP, Modbus RTU, PROFINET |