Made in Japan
Manufacturer: Kyowa Electronic Instruments Co., Ltd.
Model: BWL-20MET
Suitable for measure changing underground water levels in landslide areas.
The BWL-ET series is strain gage type water level transducers designed to measure changing underground water levels in landslide areas, etc. They do not require any compensation against fluctuations in atmospheric pressure, and thus ensure accurate measurement. A temperature measuring function lets them perform simultaneous measurement of water level and temperature.
Features
●Stainless steel enclosure ensures excellent corrosion resistance, while a built-in lightning arrester assures safe operation without receiving any effect of thunderbolts.
●Simultaneous measurement of water level and water temperature
●Easy installation, maintenance and inspection
●Applicable for measurement of underground water levels in landslide areas and water levels of dams, rivers, intake wells and tanks
Specifications
Performance
Water Lever Measurement
Rated Capacity |
Water level: 20 m |
Nonlinearity |
Within ±0.15% RO |
Hysteresis |
Within ±0.10% RO |
Repeatability |
0.05% RO or less |
Rated Output |
2 mV/V or more |
Temperature Measurement
Rated Capacity |
-20 to 60ºC |
Measurement Error |
±0.5ºC (-20 to 60ºC) |
Environmental Characteristics
Safe Temperature |
-20 to 60ºC (Non-freezing) |
Compensated Temperature |
0 to 50ºC (Non-freezing) |
Temperature Effect on Zero |
Within ±0.01% RO/ºC |
Temperature Effect on Output |
Within ±0.01%/ºC |
Electrical Characteristics
Safe Excitation |
10 V (Current: 28.5 mA) |
Recommended Excitation |
2 to 6 V (Current 5.7 to 17.1 mA) |
Input Resistance |
350 Ω ±2% at 0ºC |
Output Resistance |
450 Ω ±2% at 0ºC |
Insulation Resistance |
1000 MΩ or more (With 50 VDC applied) |
Cable |
4-conductor (0.5 mm2) capillary-equipped chloroprene shield cable, 11.3 mm diameter by 40 m long, bared at the tip
(Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads |
150% |
Weight |
Approx. 400 g |
Other |
Built-in lightning arrester