- Home
- Products
- Kyowa EDX-200A-4T Max 32 channels, 4 slots, Operating temperature range -20~65°C EDX-200A Universal Recorder
Japan, Kyowa Electronic Instruments Co., Ltd.
Kyowa EDX-200A-4T Max 32 channels, 4 slots, Operating temperature range -20~65°C EDX-200A Universal Recorder
Made in Japan
Manufacturer: Kyowa Electronic Instruments Co., Ltd.
Model: EDX-200A-4T Max 32 channels, 4 slots, Operating temperature range -20~65°C
- Equipped with a real-time digital filter 8th order digital filter can acquire beautiful waveforms.
High-speed/low-speed dual sampling Fast and slow phenomena can be measured with a reduced amount of data.
A high-speed sampling of all channels at 10kHz simultaneously (at 32 channels)Simultaneous measurement of 100 channels at up to 3kHz is possible
Can be used in high and low-temperature environments (EDX-200A-4T only) Supports -20°C~65°C - One-wire synchronization (other than EDX-200A-1)
Up to 8 units, can be used for large-scale measurement with distributed arrangement.
Feature
A compact and high-end EDX that supports a wide variety of measurements with a wide selection of conditioner cards while maintaining the convenience of the EDX-100A.
Specification
Model Name | EDX-200A-4T (w/DCS-100A)EDX-200A-4T-0 EDX-200A-4T-1 (w/DCS-100A, DCS-101A) |
---|---|
Measurement object | Strain (gauge, transducer), voltage, thermocouple, pulse (F/V), piezoelectric acceleration (built-in amplifier), CAN signal, GPS |
Analog Input | EDX series conditioner card (Note) Only compatible with CVM-41A, CDV-40B, and CDV-40B-F with temperature expansion measures. Note: The conditioner card cannot be inserted or removed. |
CAN data input | CAN card (2 ports, maximum 256 channels): CAN-41A(*) CAN-41A can be mounted in the final slot*Only CAN-41A with temperature expansion measures is supported. The CAN card cannot be inserted or removed. |
Voice memo input | 1-channel (input voice memos can be recorded together with measurement data) Remote control unit RCU-42A (sold separately) Data playback software DAS-200A (sold separately) is used to play back recorded voice memos. |
sampling
Sampling method | All channels simultaneously |
---|---|
Sampling Mode | Normal: Acquire all channels at the same sampling frequency Dual: Acquire two different sampling frequencies per channel:fast or slow |
sampling frequency | In normal sampling mode [1/2/5 series] 1Hz~100kHz 1Hz~2kHz : When CAN-41A data is measured [2nSeries】 2Hz~65536Hz 2Hz~2048Hz :CAN-41A High-speed sampling (Sf) in dual sampling mode duringdata measurement [1/2/5 series] 1Hz~100kHz 1Hz~2kHz : CAN-41A data measurement [2 nSeries: 2Hz~65536Hz 2Hz~2048Hz : nSeries】 |
Measurable number of channels | 320000 in normal sampling mode / integer part of “set sampling frequency”, except 32 in
320000-channel dual sampling mode / integer part of “set sampling frequency”, but up to 64 channels of CAN data when |
Programmable sampling frequency | The high-speed sampling frequency in dual sampling mode below(320000/”number of channels”) is (320000/”number of channels”) or less * About the “high-speed + low-speed” setting channelTwo channels of acquired data per channel |
Digital Filters | Butterworth Filter (IIR) Filter Type: Low-pass Filter, High-Pass Filter Order: Number of Amplitudes at 1~8th Cutoff Point: -3dB Attenuation Characteristics: -6dB ×N dB/oct. (N is the order of the filter)* Can be used with a low-pass filter with a conditioner card Digital filter of CAN data cannot be applied |
---|---|
Data storage | CF Card Capacity : 128M~16GB (recommended by our company) Maximum data file size (data file size that can be acquired)
When the number of measurement repetitions is 1 time 4GB/1 data file When the number of measurement repetitions is 2 or more 1GB/1 data file ( 1GB=1000000000 bytes) |
Indicator | Channel status display LEDs: 32 LEDs for main unit status display: 7 LEDs for main unit status display: 1 |
Operation switch | UP,DOWN : Display switching REC/PAUSE on OLED display for status display : Start acquisition/stop acquisition stop : Stop acquisition BAL. : Balance (balance adjustment) LOAD : Read and set conditions from CF card. : Execute optional functions setID : EDX Identification Number Setting POWER : Power Switch USB/LAN : Communication I/F Switching |
External Control Connector | CONT IN , CONT OUT (remote control, for synchronous operation) |
Communication Interface | USB (USB2.0 High Speed) 1-Port Connector Shape : Series B Receptacle LAN (10/100BASE-T)2-Port LAN IN : LAN OUT for |
Synchronous operation | Number of synchronous operations with synchronous cable (N-128) connection : Number of synchronous operation with 8 LAN cable connection : 8 units |
How to set conditions | Online setting: Set on PC via LAN or USB interfaceOffline setting:
Set by reading the setting conditions in the CF card into the instrument (DCS-100A is used to create measurement conditions) |
Saving Conditions | Conditioner setting conditions and measurement conditions can be stored in EDX’s built-in nonvolatile memory, and data can be acquired immediately under the previous measurement conditions. |
Measurement mode
Manual measurement/trigger measurement/interval measurement | |
Manual measurement | It is possible to start and stop data acquisition by user operation, or stop acquisition with a set number of data, and record voice memos at the time of this measurement. |
Trigger measurement | Automatic acquisition function (Note) Triggering with CAN data acquired by CAN-41A is not possible under preset trigger conditions. |
Interval measurement | Combination of Measurement Modes in Dual Sampling Mode for Automatic Acquisition Function Under
Predetermined Interval Conditions: |
Start/Stop Acquisition | Executed by PC, operation switch (panel surface), dedicated remote control |
---|---|
Balance adjustment operation (balance operation) | Strain input channel balance adjustment is performed by a personal computer, operation switch (panel surface), or dedicated remote control. |
Acquired Data Format | Analysis is possible using the DAS-2A data analysis software sold separately in the KS200 Republican standard format. |
Data recovery | Online collection by PC or offline collection by reading CF card directly into PC |
TEDS function | Conditioner card only for online control by PC: Only CVM-41A, CDV-40B, CDV-40B-F with temperature expansion measures are supported. |
power | DC 10~36V connector type : RM12BRD-4PH (Hirose Electric) DC power supply or AC adapter (sold separately) |
Current consumption | Approx. 2.6A (DC 12V, 40 CDV-4B mounted) |
Operating temperature range | -20~65℃ |
Operating humidity range | 20~90%(non-condensing) |
Storage temperature range | -30~70℃ |
Vibration resistance | 49.0m/s2 (5G), 5~55Hz 1 cycle 1 minute, 15 cycles per axis (non-operating) 29.4m/s2 (3G), 5~55Hz 1 cycle 1 minute, 15 cycles per axis (operating) |
Impact resistance | 196.1m/s2(30G)/11ms |
External dimensions | 185.2(W)×142.8(H)×255(D)mm not including protrusions |
mass | Main unit: Approx. 3.7kg (Approx. 40.4kg when two CDV-4B sheets are mounted) |
Standard Accessories | DC Power Cable P-76 USB Cable N-38 Ground Wire P-72 Mounted in CF Card (1GB) Slot Fuse Spare (Rated Current 8A) EDX Accessories Bag Dynamic Data Acquisition Software DCS-100A (DVD) * If the model name ends with “-0”, DCS-100A is sold separately. Instruction manual (Japanese/English, DVD) |
---|---|
Sold separately | AC Adapter for EDX-200A UIA360-1540 (SPU61A-106 15V for the US market) Fixed Adapter for EDX Dummy Panel EDX1P-DUMMY Remote Control Unit RCU-42A Monitor Unit EMON-20A synchronous cable N-128 |
Dimensions
Remarks
EDX-200A-2H/4H: CE compatible products can also be manufactured. Please contact us.
Related Products
-
KONAN YS334 Mini-type Direct-acting 3-port Solenoid Valves Normally Open Type
-
Shinano SI-1108B 3/8″ Ratchet Wrench Standard Air Tools
-
NAC – TL TYPE Stainless steel (SUS304) SF (Female thread)
-
Okazaki Seiko SHE6LH OK-HARD Coated Solid Carbide Hard Square Endmills (Long Shank, 6 Flutes)
-
Chino IR-FA Series Fiber Type Radiation Thermometer
-
Vessel No.HFBH55 Holder Attachment