PHF-S-S3-J1
Standard Cable
To Ensure Safe Usage
These models are designed for measuring oil pressure.
It is necessary to mount protection covers around the transducer for measuring air pressure.
Made in Japan
Manufacturer: Kyowa Electronic Instruments Co., Ltd.
Model: PHF-S-2MPS3A
Excellent environmental performance
●Enable to reduce weight effect on measuring objects
●After removing the connector, enables installation in a limited space by a socket wrench
Rated Capacity | 2 MPa |
---|---|
Nonlinearity | Within ±0.3% RO |
Hysteresis | Within ±0.2% RO |
Rated Output | Approx. 1.75 mV/V |
Safe Temperature | -40 to 160 ºC (Connector plug: -25 to 85ºC) |
---|---|
Compensated Temperature | -40 to 150 ºC (Connector plug: -25 to 85ºC) |
Temperature Effect on Zero | Within ±0.008% RO/ºC |
Temperature Effect on Output | Within ±0.01%/ºC |
Safe Excitation | 5 V AC or DC |
---|---|
Recommended Excitation | 1 to 2 V AC or DC |
Input Resistance | 350 Ω ±5% |
Output Resistance | 350 Ω ±5% |
Insulation Resistance | 500 MΩ (25 VDC) or more |
Standard Cable | 4-conductor (0.09 mm2) silicone shielded cable, 3 mm diameter by 4 m long Sensor side: Special connector Measuring instrument side: PRC03-12A10-7M (Shield wire is not connected to the case.) |
Safe Overloads | 150% |
---|---|
Natural Frequencies | Approx. 45 kHz |
Material | Liquid-contacting part: SUS 630 |
Weight | Approx. 20 g (Excluding cable) |
Degree of Protection | IP45 (IEC 60529) |
Mounting Screw | R1/8, male |
Compliance | Directive 2011/65/EU, (EU)2015/863 (10 restricted substances) (RoHS) |
Standard Accessories | Hexagon wrench for air vent screw |
---|---|
Optional Accessories | Standard cable PHF-S-S3-J1 |
These models are designed for measuring oil pressure.
It is necessary to mount protection covers around the transducer for measuring air pressure.
Copyright © Kouei Japan Trading | Get Quotation