,

Kyowa UCS-60B Control Software

Made in Japan
Manufacturer: Kyowa Electronic Instruments Co., Ltd.
Model: UCS-60B Control Software

The UCS-60B, a control software that draws out the performance of the data logger, is software that further extracts the performance of the data logger by remotely controlling the data logger from a PC and performing graphs, numerical displays, and arithmetic processing of measurement data on the PC.

Feature

● UCAM-60C and UCAM-65C control ● Numerical display in list format ● Up to 50 graphs can be displayed (up to 20 channels of data can be displayed in each graph) ● Measurement data can be saved in various formats Cooperative Standard (KU1) format, UCAM-70A format, CSV format, XLS format (Excel® format) ● Arithmetic processing (four arithmetic operations, statistical operations, rosette analysis) ● Reading/saving measurement conditions and arithmetic condition files ● Printer output ● English version included

Specification

Operating environment
OS Windows 8/8.1
Windows®® 10
Japanese/English, 32/64-bit support
CPU Core 2 Duo 2GHz or higher recommended
memory If the OS is 32-bit, 2GB or moreIf the OS is 64-bit, 4GB or
more
display Resolution 1024×768 or higher
interface [Serial Port]
RS-232C connection.
Can

be connected via standard serial port or USB-to-serial converter [LAN port] Used

with LAN connection [GP-IB port]

GP-IB connection
USB-GPIB Can be connected with a converter, etc.

Functions of the measurement execution unit
While monitoring data with graphs and numerical values, data acquisition is performed by automatic measurements such as manual measurements, interval measurements, and trigger measurements. In addition, arithmetic processing using various built-in functions can be performed at the same time as measurement.

Note: Specifications for UCAM-60C/65C connection are shown.
When connecting to other data loggers, there are restrictions on each specification item.

Controllable data logger UCAM-60C,UCAM-65C,UCAM-60B,UCAM-65B,UCAM-60A,UCAM-65A,UCAM-500B,UCAM-500A,UCAM-20PC
Measurement channel range CH000~CH999(UCAM-60C/65C,UCAM-60B/65B,UCAM-60A/65A,UCAM-500A/500B)

CH000~CH249(UCAM-20PC)

Measurement Functions EASY MEAS, Measure, Original, Initial
Number of repetitions (number of measurements) 0~9999 (0 is infinite times)
Calibration coefficient calculation ON/OFF setting (all channels at once)
Channel conditions Scanner type, measurement channel mode, scanning speed, calibration factor, unit, offset, reference resistance value, initial value, channel name (within 18 half-width characters and 9 full-width characters)
Interval measurement conditions International measurement start time, interval time of interval measurement, number of repetitions 0~9999 (0 is infinite times), number of steps 99
Trigger measurement conditions Trigger channel (any 4 channels), trigger channel AND/OR, trigger value, reference value, number of repetitions 0~9999 (0 is infinite), number of steps 99
Trigger interval measurement conditions Trigger channel (arbitrary 4 channels), reference value of trigger channel, AND/OR between trigger channels, interval interval time, number of repetitions 0 to 9999 (0 is infinite times), number of steps 99
Working with Measurement Condition Files Load/Save
Calculation condition setting/execution function Four arithmetic operations using channel data are possible. You can use built-in functions in arithmetic expressions.
Working with Calculation Conditions Files Load/Save
Measurement features Measurement check, Initial measurement, Monitor measurement (up to 40 channels), Real-time measurement, Automatic measurement (interval measurement, trigger measurement, trigger interval measurement), Replacement measurement (single channel/measurement channel range)
Numerical display function of measurement data
Number Window Real-time measurement, automatic measurement measurement data is displayed in a list
Display Format List display, list display, initial value measurement data display, check result display
Monitor Window Monitor measurement data is displayed in the latest list.
Graph display function of measurement data
Chart type Y-TIME,Y-CYCLE,X-Y graph,BAR graph
Number of display channels Up to 20 channels (X-Y graph has up to 10 channels)
Display operations X/Y axis magnification, X/Y axis autoscale, cursor display
Number of data that can be displayed The maximum number of measurement data that can be displayed depends on the number of measurement channels as follows.
Number of measurement channels Within 100 channels 10000 data Within 200 channels 5000 data Within 500 channels 2000 data 501 channels or more 1000 data
Measurement data storage format KU1 format, UCAM-70A format (ASCII), CSV format,
XLS format (MS-EXCEL® format)
TEDS compliant Information can be
read from sensors with built-in TEDS (UCAM-60B/C, UCAM-65B/C)
Functions of the measurement data reproduction unit
For KU1, UCAM-70A (ASCII and binary support), and UCAM-500A files, you can read/save files, display data, edit, perform calculations, extract arbitrary sections and channels, and convert files to CSV and XLS formats.
Calculation condition setting function Four arithmetic operations using channel data are possible.
You can use built-in functions in arithmetic expressions.
Working with Calculation Conditions Files Load/Save
Numerical display function of measurement data List view only
Graph display function of measurement data
Chart type Y-TIME,Y-CYCLE,X-Y GRAPH,BAR GRAPH
Number of display channels Up to 20 channels (X-Y graph has up to 10 channels)
Display operations X/Y axis magnification, X/Y axis autoscale, cursor display
Working with display condition files Load/Save
restriction
When saving measurement data in XLS format or converting measurement data files to XLS format, the following restrictions apply to the number of channels and data.
Number of channels Up to 250
Number of data Maximum 10000 With the UCS-60B, the control software for UCAM-20PC (UCS-25A) and the control software for UCAM-500A (
UCS-500A) cannot read the created measurement condition file, calculation condition file, or display condition file.
In addition, the measurement condition file created by the UCAM-60A/B/C main unit cannot be read.

REQUEST QUOTATION

PAYMENT

payment-methods

 

TOOLS & EQUIPMENT

Lifting
Eagle Clamp | Eagle Jack | Elephant | Endo Kogyo
Japan Clamp | Kanetec | Jung | KITO | Katsuyama Kikai
Kondotec | Miki Netsuren | Sanei Seiki | Taiyo

Hand Tools
Bix | Miyakawa | Nakatani Kikai | Ogura | Osakada Tool
Super Tool | TONE | Yutani

Tape
Kamoi | Kikusui | Misuzu | Nirei | Okamoto | Taiho | Teraoka

Measurement
Hasegawa | Kawaki | Kett | KGK | Line Seiki | Nagano Keiki
Niigata Seiki | Obishi Keiki | RSK | Ryoden Shonan | Sanko
Sanwa Supply | Showa Seisakusho | Showa Sokki
SK Sato | Tokyo Keiso | Tokyo Sokushin

Safety Tools
Fujii Denko | Shigematsu | Titan

Welding
Asahi Weldex | Daihen | Koike | Nissan Tanaka

Drilling
Dijet | Kansai Kogu | Nitto Kohki | Okazaki Seiko | Takeda

Chemical
Cemedine | DaitoNippon Grease | Taseto

Other Tools
Hammer Caster | Kitagawa | Matsuda Seiki | Misuz | Sanritsu
Sanyutec | Shizuoka Seiki | Toyo Kensetsu Kohki | Yamamoto
Yamari

PLANT FACILITIES

Facilities
Acokk | Bunkaboeki | Horiuchi | Konan | Murakoshi
Murakoshi Industries | Nesstech | Nihon Flux | Nikkin Flux
NFK | Omega System | Organo | Taiyo Parker | Toyo Mic

Pump
Dynaflo | Ebara | Honda Kiko | KyowaMusashino
Tsurumi

Valve
Astam | Kyowa Iron | Nachi | Nippon Daiya | Sawada
Wasino Kiki | Yoshitake

Electricity
Arkon | Asahi Bagnal | Gentos | Iwasaki | Kokosha | U_RD

CONSTRUCTION

Concrete Work
Daia | EXEN | Japan Life | Mikasa | Okasan Kiko | Taiheiyo

Railway Work
Kyoei | Sanwa Tekki | Teikoku | Toko

Scaffolding
Bullman | Okabe | Rikiman | Tsugaru

High Tension Bolt
Dong Ah | KPF | Nippon Steel Bolten | Nippon Fastener

Bolt & Nut & Washer
Hard Lock | Kishu Fastener | Matsukin | Mori Kozai
Nakaumi | Naniwa | Ogawa | Otani | Sudo | Toneji

STEEL MATERIAL

Steel & other Material
Dongil | JIS Standard | DSR | Sumitomo Wire | Winoa IKK

Pipe
Benkan

Return Top