Japan, Kyowa Electronic Instruments Co., Ltd.
Kyowa UCS-60B Control Software
Made in Japan
Manufacturer: Kyowa Electronic Instruments Co., Ltd.
Model: UCS-60B Control Software
The UCS-60B, a control software that draws out the performance of the data logger, is software that further extracts the performance of the data logger by remotely controlling the data logger from a PC and performing graphs, numerical displays, and arithmetic processing of measurement data on the PC.
Feature
● UCAM-60C and UCAM-65C control ● Numerical display in list format ● Up to 50 graphs can be displayed (up to 20 channels of data can be displayed in each graph) ● Measurement data can be saved in various formats Cooperative Standard (KU1) format, UCAM-70A format, CSV format, XLS format (Excel® format) ● Arithmetic processing (four arithmetic operations, statistical operations, rosette analysis) ● Reading/saving measurement conditions and arithmetic condition files ● Printer output ● English version included
Specification
Operating environment
OS | Windows 8/8.1 Windows®® 10 Japanese/English, 32/64-bit support |
---|---|
CPU | Core 2 Duo 2GHz or higher recommended |
memory | If the OS is 32-bit, 2GB or moreIf the OS is 64-bit, 4GB or more |
display | Resolution 1024×768 or higher |
interface | [Serial Port] RS-232C connection. Can be connected via standard serial port or USB-to-serial converter [LAN port] Used with LAN connection [GP-IB port] GP-IB connection |
Functions of the measurement execution unit
While monitoring data with graphs and numerical values, data acquisition is performed by automatic measurements such as manual measurements, interval measurements, and trigger measurements. In addition, arithmetic processing using various built-in functions can be performed at the same time as measurement.
Note: Specifications for UCAM-60C/65C connection are shown. |
|
Controllable data logger | UCAM-60C,UCAM-65C,UCAM-60B,UCAM-65B,UCAM-60A,UCAM-65A,UCAM-500B,UCAM-500A,UCAM-20PC |
Measurement channel range | CH000~CH999(UCAM-60C/65C,UCAM-60B/65B,UCAM-60A/65A,UCAM-500A/500B)
CH000~CH249(UCAM-20PC) |
Measurement Functions | EASY MEAS, Measure, Original, Initial |
Number of repetitions (number of measurements) | 0~9999 (0 is infinite times) |
Calibration coefficient calculation | ON/OFF setting (all channels at once) |
Channel conditions | Scanner type, measurement channel mode, scanning speed, calibration factor, unit, offset, reference resistance value, initial value, channel name (within 18 half-width characters and 9 full-width characters) |
Interval measurement conditions | International measurement start time, interval time of interval measurement, number of repetitions 0~9999 (0 is infinite times), number of steps 99 |
Trigger measurement conditions | Trigger channel (any 4 channels), trigger channel AND/OR, trigger value, reference value, number of repetitions 0~9999 (0 is infinite), number of steps 99 |
Trigger interval measurement conditions | Trigger channel (arbitrary 4 channels), reference value of trigger channel, AND/OR between trigger channels, interval interval time, number of repetitions 0 to 9999 (0 is infinite times), number of steps 99 |
Working with Measurement Condition Files | Load/Save |
Calculation condition setting/execution function | Four arithmetic operations using channel data are possible. You can use built-in functions in arithmetic expressions. |
Working with Calculation Conditions Files | Load/Save |
Measurement features | Measurement check, Initial measurement, Monitor measurement (up to 40 channels), Real-time measurement, Automatic measurement (interval measurement, trigger measurement, trigger interval measurement), Replacement measurement (single channel/measurement channel range) |
Numerical display function of measurement data | |
Number Window | Real-time measurement, automatic measurement measurement data is displayed in a list |
Display Format | List display, list display, initial value measurement data display, check result display |
Monitor Window | Monitor measurement data is displayed in the latest list. |
Graph display function of measurement data | |
Chart type | Y-TIME,Y-CYCLE,X-Y graph,BAR graph |
Number of display channels | Up to 20 channels (X-Y graph has up to 10 channels) |
Display operations | X/Y axis magnification, X/Y axis autoscale, cursor display |
Number of data that can be displayed | The maximum number of measurement data that can be displayed depends on the number of measurement channels as follows. |
Number of measurement channels | Within 100 channels 10000 data Within 200 channels 5000 data Within 500 channels 2000 data 501 channels or more 1000 data |
Measurement data storage format | KU1 format, UCAM-70A format (ASCII), CSV format, XLS format (MS-EXCEL® format) |
TEDS compliant | Information can be read from sensors with built-in TEDS (UCAM-60B/C, UCAM-65B/C) |
Functions of the measurement data reproduction unit
For KU1, UCAM-70A (ASCII and binary support), and UCAM-500A files, you can read/save files, display data, edit, perform calculations, extract arbitrary sections and channels, and convert files to CSV and XLS formats. | |
Calculation condition setting function | Four arithmetic operations using channel data are possible. You can use built-in functions in arithmetic expressions. |
Working with Calculation Conditions Files | Load/Save |
Numerical display function of measurement data | List view only |
Graph display function of measurement data | |
Chart type | Y-TIME,Y-CYCLE,X-Y GRAPH,BAR GRAPH |
Number of display channels | Up to 20 channels (X-Y graph has up to 10 channels) |
Display operations | X/Y axis magnification, X/Y axis autoscale, cursor display |
Working with display condition files | Load/Save |
restriction
When saving measurement data in XLS format or converting measurement data files to XLS format, the following restrictions apply to the number of channels and data. | |
Number of channels | Up to 250 |
Number of data | Maximum 10000 With the UCS-60B, the control software for UCAM-20PC (UCS-25A) and the control software for UCAM-500A ( UCS-500A) cannot read the created measurement condition file, calculation condition file, or display condition file. In addition, the measurement condition file created by the UCAM-60A/B/C main unit cannot be read. |