Electronic Counters, Japan, Line Seiki, Measurement
Line Seiki E48 Series Preset Counter
Product Made in Japan
Manufacturer: Line Seiki
Model: E48 Series
E48 Series Preset Counter
Feature
CE marking
Compliant to RoHS
Easy to edit/program (Individual digit keys)
Blue STN LCD display with white backlight
Multi-functions: prescaling; key locking; setting decimal-point position; programing initial value at resetting
Model
Models | Digits | Preset | Power source | Input | Output | Body length |
E48-101 | 6 | 1 Level preset | AC100 – 240V | Contact / Open collector | Relay output (1c) | 100mm |
E48-102 | DC12 – 24V | 64mm | ||||
E48-201 | 2 Level preset | AC100 – 240V | Relay output (Main: 1c, Sub: 1a ) | 100mm | ||
E48-301 | 1 Level preset + prewarn | |||||
E48-111 | 1 Level preset | AC100 – 240V | NPN Open Collector output | 100mm | ||
E48-112 | DC12 – 24V | 64mm | ||||
E48-211 | 2 Level preset | AC100 – 240V | 100mm | |||
E48-311 | 1 Level preset + prewarn |
* All mode key protecting function can be added. (example : E48-101K)
Description of E48 Series
- The E48 Series offers a versatile electronic preset counter in a compact 48 x 48 DIN design. Its blue STN LCD screen, illuminated with a white backlight, displays a dual-layer setup. The main section highlights the count value with large 10.0 x 5.0 mm figures, while the secondary section reveals preset values. Convenient indicators for preset levels and outputs are easily toggled with a button.Available in multiple configurations, including 1 or 2 preset levels or an added prewarn option, the E48 suits both general and batch counting tasks. You can power it using AC100-240V or DC12-24V, and it provides an external DC12V for sensors. Users can program its various modes, such as counting up to 10kHz speed, input signals, and decimal point positions, directly from the front panel. For data security, an internal EEPROM memory ensures count retention during power interruptions. Its front panel boasts IP54 protection, and terminal screws firmly anchor the wiring.Given its diverse features, the E48 stands out in applications like packaging, converting, and cut-to-length processes. Plus, it meets CE and RoHS standards.
Specification of E48 Series
Models | E48-101/111 | E48-102/112 | E48-201/211 | E48-301/311 |
Display | Blue STN LCD with white backlight; Digit Size: 10mm x 5mm | |||
No. of Digits | 6 | |||
No.of Digits Setting key | 6 | |||
Preset Level | 1 | 1 | 2 | 1 Level preset + prewarn |
Setting Range | -99999 – +999999 | |||
Prewarn Feature | – | 0 – 999999 | ||
Input Mode | Contact / Open collector Voltage input (Selectable) | |||
Input Signal | Open Collector (Sink current approx. 11mA ) L : 0 – 4V /
Voltage (Input impedance 7KΩ) L: 0 – 4V H: 6 – 30V (Available to duplex wire DC sensor.) |
|||
Count Speed | 30Hz, 1kHz, 5kHz, 10kHz (selectable) | |||
Count Mode | Add/Subtract (Add/Subtract individual input, 90° quadrature input) | |||
Count Range | -99999 – +999999 | |||
Prescale | 0.001 – 99.999 ( 0 setting is not available ) | |||
Decimal Point Position | 0.0, 0.00, 0.000, No decimal point | |||
Write | -99999 – +999999 | |||
Reset | Front panel reset, Remote reset, Auto-reset | |||
Remote Reset Time | 2msec or 20msec (selectable) | |||
Reset Mode | Modes A, B, C, D, E, F, G can be selected.
Except for standard output, Mode A only is available for other output modes. |
|||
Memory | E²PROM (10 years, can be used 100,000 times) | |||
Output Delay | E48-□0□ : Relay output /30Hz : 17ms MAX. / 1kHz,5kHz,10kHz :12ms MAX.
E48-□1□ : Open collector output /30Hz : 7ms MAX. / 1kHz,5kHz,10kHz : 2ms MAX. |
|||
Output Mode | 1 Level Preset: Standard, Equal, Lower Limit, Upper Limit
2 Level Preset: Standard, Equal, Upper-Lower Limit, Upper-Upper Limit 1 Level Preset + Prewarn: Standard, Equa |
|||
Output Time | Standard output: one-shot ( 10 – 9990ms ) or HOLD or HOLD 1 or HOLD 2 / Equal, Upper, Lower output: Latched only when
requirements are full |
|||
Key Lock | The key operation can be disabled at 4 protection levels (L1, L2, L3, L4) by selecting in Program Mode and shorting key lock terminals. | |||
Error Display | In 90° quadrature mode, an error message will be displayed on the LCD if the count range is exceeded (overflow error: underflow error : ) | |||
Power Supply | AC100 – 240V
-15%, +10% |
DC12 – 24V
-15%, +10% |
AC100 – 240V
-15%, +10% |
DC12 – 24V
-15%, +10% |
Sensor Power Source | DC12V 100mA | – | DC12V 100mA | DC12V 100mA |
Power Consumption | Approx. 7VA for AC240V | Approx. 2.5W for DC24V | Approx. 7VA for AC240V | Approx. 7VA for AC240V |
Operating Temperature | 0 – 50°C (non-freezing) 45 – 85%RH (non-condensing) | |||
Altitude | 2,000m max. | |||
Installation Environment | Over-voltage category II, Pollution degree 2 (IEC61010-1) | |||
Front Panel | IP54 (panel surface) | |||
Compliance | CE,RoHS | |||
Weight | Approx. 160g | Approx. 120g | Approx. 160g | Approx. 160g |
Dimensions
Application
Ingredient tanks in food factories
Description
Model | E60 Series |
---|---|
Application | Ingredient flow control |
Collected data | Discharged volume |
Effect | Checking the remaining amount in ingredient tanks and alerting the timing to refeed them. |
Parking garages
Description
Model | G48-N Series |
---|---|
Application | Capacity control in parking garages |
Collective data | Number of cars entering and exiting a parking garage |
Effect | Number control of cars parked in a parking garage. |
Elevating type lightning system
Description
Model | E21 Series |
---|---|
Application | Elevating type lighting systems |
Collective data | Positions |
Effect | Control positions of an elevating type lighting system. |