MAEDA KOKI MKCM Type Oil Signal

Manufacturer: Maeda Machinery Research Institute Ltd.
Model : MKCM type

Features

  • Flow switch detects the flow of fluid and turns the switch ON or OFF at the specified flow rate.
  • The switch is fixed (the setting cannot be changed later).
  • A flow detector that checks the flow of fluid by the movement of a float inside a transparent tube that allows you to see the flow of oil at a glance.
  • Comes with a protective cover. The metal protective cover   reduces   the possibility of damage from external impacts .
  • No need to worry about the installation direction.
  • A spring is used inside, so the installation position can be freely changed, such as upward, downward, or sideways.

Model List 

Model
 Dimensions (mm) [ The overall width is the cast surface, so there may be individual differences in dimensions]
Flow rate (L/min)
 Connection size
full length
Width
Depth
Minimum inner diameter
φmm
Specified range of operating flow rate
maximum
MKCM20-1TL-OFF
 Rc1/8
80
30
twenty two
6.5
0.005 (5cc) to 2
5
MKCM20-1TL-ON
MKCM20-2TL-OFF
Rc1/4
80
30
twenty two
6.5
0.005 (5cc) to 2
5
MKCM20-2TL-ON
MKCM20-3TL-OFF
Rc3/8
86
30
twenty five
6.5
 0.005 (5cc) to 2
5
MKCM20-3TL-ON
MKCM30-2TL-OFF
Rc1/4
100
44
32
9.5
 0.05 (50cc) to 5
10
MKCM30-2TL-ON
MKCM30-3TL-OFF
Rc3/8
104
44
32
9.5
 0.05 (50cc) to 5
10
MKCM30-3TL-ON
MKCM30-4TL-OFF
Rc1/2
110
44
32
9.5
 0.05 (50cc) to 5
10
MKCM30-4TL-ON
MKCM35-4TL-OFF
Rc1/2
124
49
44
 13.5
1-10
25
MKCM35-4TL-ON
MKCM35-6TL-OFF
Rc3/4
124
49
44
 13.5
1-10
25
MKCM35-6TL-ON
MKCM45-6TL-OFF
Rc3/4
142
62
50
18.0
3–15
50
MKCM45-6TL-ON
MKCM45-8TL-OFF
Rc1
142
62
50
18.0
3–15
50
MKCM45-8TL-ON

  • Please specify the details in the box when ordering or requesting a quote.
Model
MKCM □□ –  TL-OFF(ON)
Oil type 
(or oil viscosity  cSt)
 Switch operation flow rate
 L/min
  • Example: MKCM20-2TL-OFF Oil type: ISOVG32 Switch operating flow rate: 1L/min
  • *Please specify the contact type as either “OFF type” or “ON type”.
  • “OFF type”: The contact turns OFF when the flow rate drops (normally open, A contact)
  • “ON type”: The contact turns ON when the flow rate drops (normally closed, B contact)

Standard Specifications 

fluid
oil
Operating Flow Rate
Please specify a flow rate within the specified range of operating flow rates above.
(If possible, specify a flow rate value that is 1/3 or less of the minimum usable flow rate.)
connection
Rc female thread
Change to R male thread
. Combination with R male thread is also possible.
Heat Resistance Temperature
Maximum 60°C
Heat-resistant specifications (maximum 100°C) are also available.
Pressure resistance
1MPa
Pressure-resistant specifications (maximum 5MPa) are also available.
Maximum Operating Voltage
DC, AC 300V
Maximum current used
DC, AC 0.5A
Contact Capacity
50VA
Material
Transparent tube
acrylic
Heat-resistant and pressure-resistant products are made of brass tube (C3604).
Heat-resistant and pressure-resistant products cannot have the float visually inspected.
Protective cover
BC (gunmetal)
Aluminum versions are also available.
Fittings
C3604 (Brass)
SUS products are also available.
Spring
SUS304
Magnet included
float
aluminum
O-ring
Nitrile Rubber
Heat and pressure resistant specifications are made of fluororubber.
Reed Switch
Commercially available
Lead wire
(standard 200mm)
Commercially available
You can also specify the length of the lead wire and
change to a cab-tire cord.

Precautions when using flow switches

1. Precautions regarding magnetic fields 

  • Reed switches are magnetic switches, so use them in a place where they will not be affected by magnetic fields.
  • If there is a magnetic material such as iron near the reed switch, it may cause it to malfunction.

2. Electrical wiring precautions 

  • Be careful when wiring the flow switch to prevent overcurrent from flowing through the reed switch due to poor earth wiring etc.
  • Please use the flow switch as an alarm detector whenever possible.
    If you use it in conjunction with other electrical equipment, please take into consideration the effects of malfunction.
  • The lifespan of the reed switch will be extended if the operating voltage and current are kept as low as possible.
  • (Normally, the switch can be operated approximately 1 million times under conditions of 100V 0.5A.)

3. Caution regarding switch operation due to changes in oil temperature and viscosity 

If the temperature or viscosity of the oil changes, the switch may not operate at the set flow rate or the switch operating flow rate may change.

REQUEST QUOTATION

PAYMENT

payment-methods

 

TOOLS & EQUIPMENT

Lifting
Eagle Clamp | Eagle Jack | Elephant | Endo Kogyo
Japan Clamp | Kanetec | Jung | KITO | Katsuyama Kikai
Kondotec | Miki Netsuren | Sanei Seiki | Taiyo

Hand Tools
Bix | Miyakawa | Nakatani Kikai | Ogura | Osakada Tool
Super Tool | TONE | Yutani

Tape
Kamoi | Kikusui | Misuzu | Nirei | Okamoto | Taiho | Teraoka

Measurement
Hasegawa | Kawaki | Kett | KGK | Line Seiki | Nagano Keiki
Niigata Seiki | Obishi Keiki | RSK | Ryoden Shonan | Sanko
Sanwa Supply | Showa Seisakusho | Showa Sokki
SK Sato | Tokyo Keiso | Tokyo Sokushin

Safety Tools
Fujii Denko | Shigematsu | Titan

Welding
Asahi Weldex | Daihen | Koike | Nissan Tanaka

Drilling
Dijet | Kansai Kogu | Nitto Kohki | Okazaki Seiko | Takeda

Chemical
Cemedine | DaitoNippon Grease | Taseto

Other Tools
Hammer Caster | Kitagawa | Matsuda Seiki | Misuz | Sanritsu
Sanyutec | Shizuoka Seiki | Toyo Kensetsu Kohki | Yamamoto
Yamari

PLANT FACILITIES

Facilities
Acokk | Bunkaboeki | Horiuchi | Konan | Murakoshi
Murakoshi Industries | Nesstech | Nihon Flux | Nikkin Flux
NFK | Omega System | Organo | Taiyo Parker | Toyo Mic

Pump
Dynaflo | Ebara | Honda Kiko | KyowaMusashino
Tsurumi

Valve
Astam | Kyowa Iron | Nachi | Nippon Daiya | Sawada
Wasino Kiki | Yoshitake

Electricity
Arkon | Asahi Bagnal | Gentos | Iwasaki | Kokosha | U_RD

CONSTRUCTION

Concrete Work
Daia | EXEN | Japan Life | Mikasa | Okasan Kiko | Taiheiyo

Railway Work
Kyoei | Sanwa Tekki | Teikoku | Toko

Scaffolding
Bullman | Okabe | Rikiman | Tsugaru

High Tension Bolt
Dong Ah | KPF | Nippon Steel Bolten | Nippon Fastener

Bolt & Nut & Washer
Hard Lock | Kishu Fastener | Matsukin | Mori Kozai
Nakaumi | Naniwa | Ogawa | Otani | Sudo | Toneji

STEEL MATERIAL

Steel & other Material
Dongil | JIS Standard | DSR | Sumitomo Wire | Winoa IKK

Pipe
Benkan

Return Top