Miyawaki GH60D Ball Float Steam Traps

Manufacturer: MIYAWAKI Inc.
Model: GH60D

Features

Quick startup
Automatically discharges initial air and cold condensate. The diaphragm air vent follows the saturation temperature and prevents air and steam locking.

Suitable for medium to high capacity steam processes
Adjust the degree of valve opening according to volume of condensate generated to provide maximized heat exchange capacity.

Condensate recovery
With its high degree of back pressure tolerance, this model supports condensate recovery.

Easy maintenance

For quick and easy maintenance, this model can be repaired directly in line.

High discharge capacity
A double ported balance valve provides a large discharge capacity in comparison with single valve models.

Typical applications

Suitable for use in industrial plant systems, foodstuff devices, and dyeing/cleaning devices.

Dimensions/Weight

Flanged

Size Dimensions (mm) Dimensions (in) Weight
L H1 H2 W1 W2 L H1 H2 W1 W2 (kg) (lb)
2” 320 155 250 90 410 12.6 6.1 9.8 3.5 16.1 75,0 165.4
2 1/2”

*Available flange standards: ASME/JPI 150lb, 300lb, DIN PN40, JIS 10K, 16K, 20K
*Customized face-to-face dimensions on request.
*Please contact MIYAWAKI for further information.

Specifications

Model Connection Max. operating pressure Max. operating differential pressure Max. operating temperature Air vent type Body material
Type Size PMO
(MPa)
PMO
(psig)
⊿PMX
(MPa)
⊿PMX
(psig)
TMO
(℃)

TMO
(℉)

GH60D-2F Flanged

FF,RF*

2” 0,2 29 0,2 29 220 428 Diaphragm Cast steel

SCPH2/WCB

2 1/2”
GH60D-6F 2” 0,6 87 0,6 87
2 1/2”
GH60D-10F 2” 1,0 145 1,0 145
2 1/2”
GH60D-21F 2” 2,1 305 2,1 305
2 1/2”

*Available flange standards: ASME/JPI 150lb, 300lb, DIN PN40, JIS 10K, 16K, 20K

The highest permitted pressure (PMA) is 4.0 MPa (580 psig), while the peak allowable temperature (TMA) reaches 400°C (752°F). The maximum working back pressure (PMOB) corresponds to 90% of the pressure on the inlet side.

*ASTM material (WCB) on request.

  • This product uses a double ported balance valve system so if the actual condensate volume is significantly lower than the product’s discharge capacity, there may be a steam leak.

Discharge Capacity

GH60D

 

REQUEST QUOTATION

PAYMENT

payment-methods

 

TOOLS & EQUIPMENT

Lifting
Eagle Clamp | Eagle Jack | Elephant | Endo Kogyo
Japan Clamp | Kanetec | Jung | KITO | Katsuyama Kikai
Kondotec | Miki Netsuren | Sanei Seiki | Taiyo

Hand Tools
Bix | Miyakawa | Nakatani Kikai | Ogura | Osakada Tool
Super Tool | TONE | Yutani

Tape
Kamoi | Kikusui | Misuzu | Nirei | Okamoto | Taiho | Teraoka

Measurement
Hasegawa | Kawaki | Kett | KGK | Line Seiki | Nagano Keiki
Niigata Seiki | Obishi Keiki | RSK | Ryoden Shonan | Sanko
Sanwa Supply | Showa Seisakusho | Showa Sokki
SK Sato | Tokyo Keiso | Tokyo Sokushin

Safety Tools
Fujii Denko | Shigematsu | Titan

Welding
Asahi Weldex | Daihen | Koike | Nissan Tanaka

Drilling
Dijet | Kansai Kogu | Nitto Kohki | Okazaki Seiko | Takeda

Chemical
Cemedine | DaitoNippon Grease | Taseto

Other Tools
Hammer Caster | Kitagawa | Matsuda Seiki | Misuz | Sanritsu
Sanyutec | Shizuoka Seiki | Toyo Kensetsu Kohki | Yamamoto
Yamari

PLANT FACILITIES

Facilities
Acokk | Bunkaboeki | Horiuchi | Konan | Murakoshi
Murakoshi Industries | Nesstech | Nihon Flux | Nikkin Flux
NFK | Omega System | Organo | Taiyo Parker | Toyo Mic

Pump
Dynaflo | Ebara | Honda Kiko | KyowaMusashino
Tsurumi

Valve
Astam | Kyowa Iron | Nachi | Nippon Daiya | Sawada
Wasino Kiki | Yoshitake

Electricity
Arkon | Asahi Bagnal | Gentos | Iwasaki | Kokosha | U_RD

CONSTRUCTION

Concrete Work
Daia | EXEN | Japan Life | Mikasa | Okasan Kiko | Taiheiyo

Railway Work
Kyoei | Sanwa Tekki | Teikoku | Toko

Scaffolding
Bullman | Okabe | Rikiman | Tsugaru

High Tension Bolt
Dong Ah | KPF | Nippon Steel Bolten | Nippon Fastener

Bolt & Nut & Washer
Hard Lock | Kishu Fastener | Matsukin | Mori Kozai
Nakaumi | Naniwa | Ogawa | Otani | Sudo | Toneji

STEEL MATERIAL

Steel & other Material
Dongil | JIS Standard | DSR | Sumitomo Wire | Winoa IKK

Pipe
Benkan

Return Top