Musashi SuperΣCMⅣ Pro Fully digitally controlled dispenser

Manufacturer: Musashi Engineering, Inc.
Model: SuperΣCMⅣ Pro
Features
■The independent AIR OUT unit maintains the highest dispensing response and accuracy even in long piping environments!
■Equipped with a temperature control controller. It can both heat and cool the syringe, making it possible to suppress fluctuations in the amount of application caused by rising liquid temperature.
Specifications
Fully digitally controlled dispenser SuperΣCMIV Pro | ||||||
---|---|---|---|---|---|---|
Model | S-SIGMA-CM4P-CTR-V7-N | S-SIGMA-CM4P-CTR-V7-P | S-SIGMA-CM4P-CTR-V2-N | S-SIGMA-CM4P-CTR-V2-P | S-SIGMA-CM4P-CTR-V05-N | S-SIGMA-CM4P-CTR-V05-P |
Discharge pressure setting range Σ function ON | 30.0 to 700.0 [kPa] | 20.0 to 200.0 [kPa] | 5.0 to 50.0 [kPa] | |||
Discharge pressure setting range Σ function OFF | 20.0 to 700.0 [kPa] | 5.0 to 200.0 [kPa] | 0.5 to 50.0 [kPa] | |||
Discharge time setting range Σ function ON | Timed mode: 0.020 to 9999.999 [s] Manual mode: 0.035 to 9999.999 [s] | Timed mode: 0.020 to 9999.999 [s] Manual mode: 0.035 to 9999.999 [s] | Timed mode: 0.020 to 9999.999 [s] Manual mode: 0.035 to 9999.999 [s] | Timed mode: 0.020 to 9999.999 [s] Manual mode: 0.035 to 9999.999 [s] | ||
Discharge time setting range Σ function OFF | 0.001 to 9999.999 [s] | 0.001 to 9999.999 [s] | 0.001 to 9999.999 [s] | 0.001 to 9999.999 [s] | ||
Dispensing Mode | Timed mode, manual mode | Timed mode, manual mode | Timed mode, manual mode | Timed mode, manual mode | ||
Vacuum pressure setting range | 0.00 to -5.00 [kPa] | 0.00 to -5.00 [kPa] | 0.00 to -5.00 [kPa] | 0.00 to -5.00 [kPa] | ||
Key Features | Automatic head difference correction, automatic drip prevention, automatic remaining amount warning, alpha correction, delta correction, remaining amount display correction, vacuum pressure correction, discharge counter, stopwatch, interval discharge, discharge condition correction, auto increment, auto slope, express shot, date and time, operation history, discharge pressure monitoring, self-diagnosis, ECO mode (*), sleep mode, I/O function allocation, password lock, display unit switching (kPa/bar), solenoid valve alarm, solenoid valve error, supply air pressure error, exhaust error, vacuum pressure error, channel copy, parameter backup, auto-tuning | |||||
Signal Specifications | NPN | PNP | NPN | PNP | NPN | PNP |
Number of Channels | 400CH |
Related Products
-
Musashi Tortoiseshell candy modeling system
-
Musashi MLC-6500 FPD Fully Automatic Seal Dispensing Machine
-
Musashi MPP-5-S Volumetric Measuring Digital Control Dispenser MEASURING MASTER
-
Musashi Ultra-high speed reagent spotting system JET SPOTTER
-
Musashi Multicolor Decoration System
-
Musashi FCD1000 Fully automatic substrate coating machine