Nakatani HS290L1 Jet Furnace

Manufacturer: Nakatani Co., Ltd.
Model: HS290L1

Features

Main functions and safety devices
3P Code
This is a 2P/3P power cord (with a snap-on plug).
Stacking (stacked storage)
When stored, the HS290L1 can be stacked up to three levels, and the HS290-L1T80 can be stacked up to two levels.
Long-lasting (long-lasting burn)*
When the oil tank is full, it will burn for 18 hours. *-L1T80 only
Alarm Monitor
A lamp or error code will notify you when a safety device has been activated.
Earthquake resistance (earthquake-resistant automatic fire extinguishing)
It will automatically extinguish the fire when a strong earthquake or impact occurs.
Ignition (Ignition Safety)
It will automatically extinguish the fire in the event of ignition failure, mid-fire, abnormal combustion, or running out of oil.
Power outage (power outage safety)
Prevents the unit from automatically starting operation when power is restored after a power outage.
Overheating Prevention
The heater will automatically shut off if the inside of the heater becomes abnormally overheated.
Overload (overload protection)
If an overcurrent occurs, the electrical circuit will be cut off and operation will stop.
High voltage (high voltage stop)
If the power supply voltage becomes abnormally high during operation, the operation will stop.
Low voltage (low voltage alarm)
An alarm will sound when the power supply voltage is abnormally low.
HS290-L1 / HS290-L1T80
Heat output 33.3kW
Operating noise (50/60Hz) 72/74dB