NOHMI BOSAI FAPN105N Series Fire Alarm Panel

Made in Japan
Manufacturer: NOHMI BOSAI
Model: FAPN105N Series

FEATURES

  • Conventional type available for 10 and 20 fire zones
  • Alarm verification type (Verification time: 60 seconds)
  • Various test functions: fire indication test, alarm verification time test, auxiliary power supply test, automatic after-test resetting
  • Self-diagnosis system
  • Misoperation inhibition function
  • Built-in telephone system
  • Back-up power supply (Ni-Cd battery, 24VDC)
  • Large fire alarm symbol for easy visual recognition
  • Fire zone indication by both zone nameplates and a digital display
  • History list for last 1,000 events
  • 3 auxiliary LED indicators
  • General fire alarm cut-off switch
  • Functions programmable at site
  • Arrow keys for easy database setting
  • 4 programmable option switches for signal cut-off
  • Built-in surge arrester for power lines
  • 10 programmable dry contacts interlocked by zone alarm signals

DESCRIPTION

The FAPN105N series fire alarm panel was developed to improve panel-front recognize-ability and functional operability from the viewpoint of users.

<Alarm inputs>

Conventional fire detectors and manual alarm boxes are connected to alarm receiving circuits to produce visual and audible alarms on the panel and to actuate alarm bells. The FAPN105N series fire alarm panel has a line-up of 10 and 20 alarm receiving circuits (zones). Each alarm receiving circuit has an alarm verification function.

<Auxiliary inputs>

Three system signals can be received by three auxiliary receiving circuits to be indicated by three auxiliary LED indicators on the panel. These signals should be non-alarm supervisory signals such as sprinkler water tank water level indication and low-air pressure switch activation on dry-pipe sprinkler system.

<Signal outputs>

10 programmable contacts are available for signal output. A group of signals for a hydrant pump starting relay box and a group of signals for an annunciator panel are also available.

<Digital display>

The 3-digit digital indicator displays not only alarm-activated zones but also trouble signals and system event history list.

<Alarm bell activation>

There are 2 alarm bell activation modes. One actuates all alarm bells at the same time, called All Local Alarm ON. The other actuates a group of alarm bells depending on the location of a fire, called localized alarm. One pair of terminals is available for the general alarm. The programmable contacts are used for the localized alarm.

<Self-diagnosis>

The followings are monitored at all times:

  • Open circuit of detector wiring
  • Battery power failure
  • Circuit voltage trouble
  • Fuse blowout
  • Transmission fault
  • Open/short alarms of local bells silencing circuit interlocked with emergency PA system
  • Connection fault (speaker)
  • Memory trouble
  • Database trouble
  • CPU error The fire alarm receiving circuits are tested once a week and the test results are recorded in the history list.

<Programming>

The following settings are programmable in database setting mode:

  • Unused alarm receiving circuits do not need dummy current loads
  • Alarm verification on alarm receiving circuits
  • Three customizable LED indicators for auxiliary input signals
  • Interlocking of 10 dry contacts for zone alarm signals
  • Option switches on panel front

Specification

Model No. FAPN105N SERIES
Type Conventional type
Power Supply 220VAC 50/60Hz
Auxiliary Power Supply Ni-Cd battery (24VDC, 0.45Ah)
Circuits Voltage 5, 24, 48VDC, 24VAC
Alarm Verification Time Thermal detector: 10sec; Smoke detector: 60sec.
Power Consumption Monitoring: approx. 30VA
Alarm: approx. 68VA
Maximum Number of Devices Supported Spot type smoke detectors: 30/zone (max, 300/10-zone, 600/20-zone)
Alarm bells : 30 (24VDC, 10mA/bell)
Location lamps: 7 (30V, 2W/lamp); 29 (24VDC, 15mA/lamp)
Ambient Temperature and Humidity 0 to 40°C, 20~85% RH
Alarm Input Circuit Loop Resistance Less than 50 Ω/loop
End-of-Line Resistor 10kΩ, 1/2W
Materials (Enclosure) ABS resin with 94UL-V2 flammability rating
Color Off-White (Nohmi white): approximating Munsell N8.7 or equivalent
Weight Approx. 4kg
Dimensions 480mm(H) x 340mm(W) x 90mm(D)

Typical wiring diagram

REQUEST QUOTATION

PAYMENT

payment-methods

 

TOOLS & EQUIPMENT

Lifting
Eagle Clamp | Eagle Jack | Elephant | Endo Kogyo
Japan Clamp | Kanetec | Jung | KITO | Katsuyama Kikai
Kondotec | Miki Netsuren | Sanei Seiki | Taiyo

Hand Tools
Bix | Miyakawa | Nakatani Kikai | Ogura | Osakada Tool
Super Tool | TONE | Yutani

Tape
Kamoi | Kikusui | Misuzu | Nirei | Okamoto | Taiho | Teraoka

Measurement
Hasegawa | Kawaki | Kett | KGK | Line Seiki | Nagano Keiki
Niigata Seiki | Obishi Keiki | RSK | Ryoden Shonan | Sanko
Sanwa Supply | Showa Seisakusho | Showa Sokki
SK Sato | Tokyo Keiso | Tokyo Sokushin

Safety Tools
Fujii Denko | Shigematsu | Titan

Welding
Asahi Weldex | Daihen | Koike | Nissan Tanaka

Drilling
Dijet | Kansai Kogu | Nitto Kohki | Okazaki Seiko | Takeda

Chemical
Cemedine | DaitoNippon Grease | Taseto

Other Tools
Hammer Caster | Kitagawa | Matsuda Seiki | Misuz | Sanritsu
Sanyutec | Shizuoka Seiki | Toyo Kensetsu Kohki | Yamamoto
Yamari

PLANT FACILITIES

Facilities
Acokk | Bunkaboeki | Horiuchi | Konan | Murakoshi
Murakoshi Industries | Nesstech | Nihon Flux | Nikkin Flux
NFK | Omega System | Organo | Taiyo Parker | Toyo Mic

Pump
Dynaflo | Ebara | Honda Kiko | KyowaMusashino
Tsurumi

Valve
Astam | Kyowa Iron | Nachi | Nippon Daiya | Sawada
Wasino Kiki | Yoshitake

Electricity
Arkon | Asahi Bagnal | Gentos | Iwasaki | Kokosha | U_RD

CONSTRUCTION

Concrete Work
Daia | EXEN | Japan Life | Mikasa | Okasan Kiko | Taiheiyo

Railway Work
Kyoei | Sanwa Tekki | Teikoku | Toko

Scaffolding
Bullman | Okabe | Rikiman | Tsugaru

High Tension Bolt
Dong Ah | KPF | Nippon Steel Bolten | Nippon Fastener

Bolt & Nut & Washer
Hard Lock | Kishu Fastener | Matsukin | Mori Kozai
Nakaumi | Naniwa | Ogawa | Otani | Sudo | Toneji

STEEL MATERIAL

Steel & other Material
Dongil | JIS Standard | DSR | Sumitomo Wire | Winoa IKK

Pipe
Benkan

Return Top