RIKEN OPTECH CORPORATION RLG Load Monitor

Manufacturer: RIKEN OPTECH CORPORATION
Model: RLG

Multiple alarm functions incorporated high performance automatic Load Monitoring System

RLG series load monitor has the function of detecting the press load with a strain gauge. It displays the accurate load during press processing, outputs stop signals, and stops the press machine immediately when it detects abnormalities. Multiple detection modes incorporated cannot be ignored when there are eccentric loads for each stroke, and furthermore, load monitoring extends the life of dies, prevents friction and wear of presses, also promotes quality control and rationalization.

Use Bluetooth communication to transfer the load data acquired from the main unit of the RLG body to your Android terminal. Each terminal transfers acquired data to a computer easily, automatically converting it to CSV format. As data analysis is possible, it can be used for various applications.

Features

  • Monitoring overload
  • Responding to eccentric load by monitoring left and right separately
  • Comparing load every stroke shows the effect for preventing die failure caused by double-hit and misfeed
  • Respond to estimate the regrinding period of the die and changes of material thickness
  • Two functions, “Absolute-value detection” and “Rolling average detection” are incorporated
  • Knowing the suitable load for products facilitates selecting the press machine.
  • Digital LED and bar display show the currant load condition clearly and easy to understand

Additional function in option (PC Software, Mariner AD)

  • Load waveform analysis (load waveform analysis software, Mariner AD)
  • Display peak load history
  • SPC chart display function (statistical process management)

Standard installation of Bluetooth function

  • Supports smartphones/tablet equipped with Android
  • Storage function for more than 1,000 load waveform
  • Obtained latest 100 overload
  • You can download the software from the Helm Instrument website.
  • Supports Ethernet (additional board required)

Specifications

Electrical SpecificationsPower supply90-264 VAC
Current consumption100mA-220 VAC / 115mA-200 VAC
No.of channels2 channels(RLG-2) / 4 channels
A/D conversion method12 bit
Normal mode rejection50db at 2,000 gain (between + innput and – input)
CalibrationManual calibration
Isolation500VDC continuous between inputs and chassis ground
Environmental SpecificatinsWorking temperature0°C-60°C(32°F-140°F)
Input SpecificationsInput typeStrain gauge (350Ω, 700Ω)
Input impedance1K
Low range gainMax. gain 1176
Cal. resistor(140k-ohm)Min. gain 54
High range gainMax. gain 6959
Cal. resistor(1meg-ohm)Min. gain 347
Display resolutionUp to 0.1% of full scale
Overall module accuracy1% of full scale
A/D sample rate100 microseconds
Output SpecificationsAlarm relayDry contact (10A 240VAC)