Sanshu Sangyo Cold Storage

Manufacturer: Sanshu Sangyo Co., Ltd.

Compact low-temperature storage for rice – “Rice Storage Warehouse”

No drain required, making installation simple.
Optimally stores rice and vegetables across a wide temperature range!

Easy-to-read large screen and simple control panel

Operation Mode Recommended Temperature Approximate Humidity
Rice Mode 10~13℃ 65~75%
Vegetable Mode 3~7℃ 80~90%

▸ Rice, vegetables, and beverages can be stored at low temperatures.
▸ Quiet operation that’s gentle on daily life (40 dB).
▸ Always clean with antibacterial and anti-mold features.
▸ No drain required, making installation hassle-free.
▸ Easy level adjustment, convenient for installation and relocation.
▸ Operates efficiently in ambient temperatures from 0 to 43°C, even during the high heat of summer (excluding some models).

Prefab panel pre-assembled type with casters for easy installation

DKC-12A DKC-14A DKC-21A
DKC-28A DKC-32A

Specifications

Width (Panel) 0.2 Tsubo Type (DKC-12A) 0.2 Tsubo Type (DKC-14A) 0.3 Tsubo Type (DKC-21A)
Storage Capacity Estimate (30 kg rice bags) 12 bags (6 shelves) 14 bags (7 shelves) 21 bags (10.5 shelves)
External Dimensions mm
Internal Capacity (Effective Capacity) 932 (863) L 1035 (965) L 1461 (1363) L
Cooling Unit Model Name LCDMP02AS LCDMP05AS
Set Temperature Range 2~15°C
Operable Ambient Temperature Range 0~43°C
Power Supply Single-phase 100V
Cooling Capacity 0.38/0.44kW 0.49/0.54 kW
Operating Noise 40/40dB
Compressor Motor Output 0.15 kW 0.25 kW
Refrigerant Used R407C
Product Weight Panel (Cooling Unit) 95kg (26kg) 102kg (26kg) 125kg (26.5kg)
Width (Panel) 0.2 Tsubo Type (DKC-12A) 0.2 Tsubo Type (DKC-14A)
Storage Capacity Estimate (30 kg rice bags) 12 bags (6 shelves) 14 bags (7 shelves)
External Dimensions mm
Internal Capacity (Effective Capacity) 932 (863) L 1035 (965) L
Cooling Unit Model Name LCDMP02AS
Set Temperature Range 2~15°C
Operable Ambient Temperature Range 0~43°C
Power Supply Single-phase 100V
Cooling Capacity 0.38/0.44kW
Operating Noise 40/40dB
Compressor Motor Output 0.15 kW
Refrigerant Used R407C
Product Weight Panel (Cooling Unit) 95kg (26kg) 102kg (26kg)

Prefabricated refrigerator

Preserves freshness, enhances ingredients, and protects quality – Sanshu Prefabricated Refrigerator

  1. Easy and Quick Installation with Prefabricated System
    Compared to conventional construction methods, the time from order to delivery is much faster. Naturally, we ensure responsible installation.
  2. Energy-Saving Design
    A reliable combination of highly heat-resistant and durable urethane foam panels with Daikin low-temperature air conditioning (unit type).
  3. Double Safety Escape Device Included
    In the unlikely event of being trapped, the door can be opened from inside the storage.
  4. Light and Durable Panels
    Panels are available in optimal thickness for different humidity ranges and heights can be tailored to your needs.
  5. Daikin Low-Temperature Air Conditioner
    Features three-way airflow for high-quality cooling with no uneven cooling.
  6. Panel Connection System Enables Disassembly and Expansion

※Sliding doors are also available.

A user-friendly control panel that operates with just the push of a button.

  • Temperature can be set from -5°C to 15°C in 1°C increments.
  • Interior temperature settings and displays are easy to read with illuminated digital indicators.
  • Switching between rice and vegetable modes is done with one touch (with indicator lamp).
  • Panel displays abnormalities in equipment or sensors.
  • Microcomputer control enables highly accurate temperature and humidity management.

The 0.1 tsubo type has a different design.

Operation Mode Set Temperature Humidity Control
Rice Mode Optimal temperature is 13°C or below 60~70%
Vegetable Mode 2~7℃ 80~90%

Defrosting is automatically controlled by the microcomputer, ensuring defrosting in vegetable mode is performed at the appropriate timing for energy-efficient operation.

L-Type (Ceiling-mounted, 0.5 tsubo or larger)

Efficiently utilizes limited space. Space-saving, lightweight, and requires minimal construction.

  • Low-temperature air conditioner (refrigeration) -5°C to 15°C
  • Ceiling-mounted type (air-cooled integrated type)
  • LCTLP
  • Hot gas system
  • LCDMP1A (off-cycle system) for 2°C to 15°C is also available.
  • Model Name Cooling Capacity (kW) Electrical Characteristics Compressor/Motor Output (kW) Operating Noise (dB) Weight (kg) External Dimensions (mm)
    (H × W × D)
    Drain Piping
    Operating Current (A) Power Consumption (kW) Power Factor (%)
     LCTLP1A 1.19/1.33 3.44/3.53  0.89/1.06  74.5/86.8 0.75  52.5/54.5  38 613×750×540 Outer Diameter: φ26 (VP20)
      LCTLP1X5A 1.74/1.97 4.63/4.16  1.14/1.29 71.2/89.6 1.1  54.5/57.5 50  714×900×656 Outer Diameter: φ32 (VP25)
     LCTLP2A  2.41/2.66 6.51/6.64 1.80/2.14  79.9/93.1 1.8  54.5/57.5 60 714×900×656
  • Separate Type (Ceiling-Hung)

Ensures sufficient interior height. By placing the refrigeration unit outside, it accommodates various installation locations.
Equipped with an inverter, saving approximately 30% on annual electricity costs.

  • Low-temperature air conditioner (refrigeration) -5°C to 20°C
  • Ceiling-hung type (air-cooled separate type)
  • LSVLP
  • Hot gas system

LSVMP (off-cycle system) for 5°C to 15°C is also available.

Model Name Cooling Capacity
(kW)
Electrical Characteristics Compressor/
Motor Output (kW)
Exterior Unit Operating Noise (dB) Weight (kg) External Dimensions (mm) (H × W × D) Drain Piping
Operating Current
(A)
Power Consumption
(kW)
Power Factor
(%)
Exterior Unit
LSVLP1A 1.40/1.40 3.2/3.0 0.89/0.88 80.0/84.9 0.98 LSVLP1A 12 275×540×530 VP20
(Outer Diameter: φ26)
LSVLP1A 48/48 51 735×830×300
LSVLP1X5A 2.10/2.10 4.4/4.2 1.21/1.19 79.4/81.8 1.25 LSVLP1X5A 22 335×615×640 PT3/4

Male Thread

LSVLP1X5A 49/49 51 735×830×300
LCTLP2A 2.80/2.80 6.1/6.3 1.80/1.86 85.2/85.2 1.95 LCTLP2A 22 335×615×640
LCTLP2A 51/51 62 770×900×320
LCTLP3A 4.63/4.63 8.6/8.9 2.72/2.77 91.3/89.8 2.38 LCTLP3A 28 505×1075×500 PT1

Male Thread

LCTLP3A 53/53 62 770×900×320

Cold Storage Size List

Tsubo Count 0.75 tsubo 1.0 tsubo 1.5 tsubo
Ceiling-Mounted Model RH-19-0.75PL RH-19-11.0PL RH-19-1.5PL RH-19-1.5PLH
Unit Type LCTLP1A LCTLP1A LCTLP1A LCTLP1X5A
Separate Type Model RH-19-0.75PLS RH-19-1.0PLS RH-19-1.5PLS RH-19-1.5PLHS
Unit Type LSVLP1AC LSVLP1AC LSVLP1AC LSVLP1X5AC
External Dimensions (mm)
(Storage Capacity Estimate)※For the separate type, please exclude the unit height.
Tsubo Count 2.0 tsubo 2.5 tsubo 3.0 tsubo
Ceiling-Mounted Model RH-19-2.0PL RH-19-2.0PLH RH-19-2.5PL RH-19-2.5PLH RH-19-3.0PL RH-19-3.0PLH
Unit Type LCTLP1X5A LCTLP2A LCTLP1X5A LCTLP2A LCTLP2A LCTLP1X5A x 2 units
Separate Type Model RH-19-2.0PLS RH-19-2.0PLHS RH-19-2.5PLS RH-19-2.5PLHS RH-19-3.0PLS RH-19-3.0PLHS
Unit Type LSVLP1X5AC LSVLP2AC LSVLP1X5AC LSVLP2AC LSVLP2AC LSVLP3AC
External Dimensions (mm)
(Storage Capacity Estimate)※For the separate type, please exclude the unit height.
  • Ceiling-mounted types require a clearance of 750mm or more above the panels.
  • The standard length for refrigerant piping in separate types is within 5 meters.
  • Panel surfaces are made of colored copper sheets (colored aluminum is also available).
  • The standard interior height is 1900mm, with options for 2200mm, 2400mm, 2600mm, 2800mm, and 3000mm, including custom specifications.
  • Sizes larger than 3.0 tsubo and various door types are available for selection.
  • Standard Accessories: Interior light (moisture-proof type, 100V/400W), slatted flooring, and a remote-controlled thermostat for humidity settings.
  • Air conditioner models may be changed without prior notice for improvement purposes.
  • Installation is limited to placement on a concrete foundation.

REQUEST QUOTATION

PAYMENT

payment-methods

 

TOOLS & EQUIPMENT

Lifting
Eagle Clamp | Eagle Jack | Elephant | Endo Kogyo
Japan Clamp | Kanetec | Jung | KITO | Katsuyama Kikai
Kondotec | Miki Netsuren | Sanei Seiki | Taiyo

Hand Tools
Bix | Miyakawa | Nakatani Kikai | Ogura | Osakada Tool
Super Tool | TONE | Yutani

Tape
Kamoi | Kikusui | Misuzu | Nirei | Okamoto | Taiho | Teraoka

Measurement
Hasegawa | Kawaki | Kett | KGK | Line Seiki | Nagano Keiki
Niigata Seiki | Obishi Keiki | RSK | Ryoden Shonan | Sanko
Sanwa Supply | Showa Seisakusho | Showa Sokki
SK Sato | Tokyo Keiso | Tokyo Sokushin

Safety Tools
Fujii Denko | Shigematsu | Titan

Welding
Asahi Weldex | Daihen | Koike | Nissan Tanaka

Drilling
Dijet | Kansai Kogu | Nitto Kohki | Okazaki Seiko | Takeda

Chemical
Cemedine | DaitoNippon Grease | Taseto

Other Tools
Hammer Caster | Kitagawa | Matsuda Seiki | Misuz | Sanritsu
Sanyutec | Shizuoka Seiki | Toyo Kensetsu Kohki | Yamamoto
Yamari

PLANT FACILITIES

Facilities
Acokk | Bunkaboeki | Horiuchi | Konan | Murakoshi
Murakoshi Industries | Nesstech | Nihon Flux | Nikkin Flux
NFK | Omega System | Organo | Taiyo Parker | Toyo Mic

Pump
Dynaflo | Ebara | Honda Kiko | KyowaMusashino
Tsurumi

Valve
Astam | Kyowa Iron | Nachi | Nippon Daiya | Sawada
Wasino Kiki | Yoshitake

Electricity
Arkon | Asahi Bagnal | Gentos | Iwasaki | Kokosha | U_RD

CONSTRUCTION

Concrete Work
Daia | EXEN | Japan Life | Mikasa | Okasan Kiko | Taiheiyo

Railway Work
Kyoei | Sanwa Tekki | Teikoku | Toko

Scaffolding
Bullman | Okabe | Rikiman | Tsugaru

High Tension Bolt
Dong Ah | KPF | Nippon Steel Bolten | Nippon Fastener

Bolt & Nut & Washer
Hard Lock | Kishu Fastener | Matsukin | Mori Kozai
Nakaumi | Naniwa | Ogawa | Otani | Sudo | Toneji

STEEL MATERIAL

Steel & other Material
Dongil | JIS Standard | DSR | Sumitomo Wire | Winoa IKK

Pipe
Benkan

Return Top