Measures CO2 (carbon dioxide), temperature and humidity
When the CO2 concentration status becomes high, the LED will notify you.
When the CO2 concentration exceeds the set value, you will be notified by sound.
Recommended for offices, schools and medical facilities
Power supply type by AC adapter
Can be installed on the wall
Features of CHE-C2
A wall-mounted CO2 carbon dioxide monitor that measures and displays CO2 (carbon dioxide), temperature, and humidity.
You can watch the indoor air environment such as offices / meeting rooms of companies, public facilities such as schools, libraries and hospitals, and commercial facilities.
When the concentration of CO2 (carbon dioxide) becomes high, it will notify you with an alarm sound and LED.
You can set the alarm to sound when the CO2 carbon dioxide concentration exceeds the set value. You can also set the alarm sound ON / OFF.
AC power supply type.
Specifications
Measurement items and measurement range | CO2 / 0-9999ppm, temperature / 0-50 ℃, humidity / 0-85% RH |
---|---|
Resolution | CO2 / 1ppm, temperature / 0.1 ℃, humidity / 0.1% RH |
Accuracy | CO2 / ± 70ppm + 3% rdg (400-5000ppm), temperature / ± 0.8 ℃ (10-50 ℃) maximum ± 1.5 ℃, humidity / ± 3% RH (30-75% RH) |
LED display (CO2) | 3LED (0 to 599ppm) / Safe 6LED (600 to 1199ppm) / Be careful 9LED (1200 to 9999PPM) / Let’s ventilate |
Alarm sound | Alarm sounds CO2 (carbon dioxide) concentration value can be set, alarm can be turned ON / OFF |
CO2 sensor type | Non-dispersive infrared (NDIR) gas sensor |
Usage environment | 0 to 50 ° C, 85% RH or less (no condensation) |
Storage environment | 0-60 ℃, 85% RH or less (without condensation) |
Installation height standard | 2-2.5m |
Measurement guideline range | 50 square meters |
Power supply | Power supply by AC adapter |
Size | W392 x D292 x H42 mm |
Weight | Approximately 1.42 kg (panel monitor body only) |
Set | CO2 panel monitor, AC adapter, tapping screws x 4, anchors x 4, instruction manual / warranty |
Correction function (calibration function) | If the correction function is used continuously for 5 to 7 days with the power turned on, accurate automatic correction (calibration) will be executed. <What is automatic calibration (correction)>* Although it depends on the product, it is a function that considers the minimum measured value of carbon dioxide for 5 to 7 days as 400PPM and corrects it step by step. * The reason why 400PPM is the standard is that the World Meteorological Organization (WMO) has announced that the average weekly CO2 concentration in the world is 400PPM, so 400PPM is the standard value. |
Related Products
-
Sanwa Supply CR-TMSTN1 Stand For PSC-TMCMS1 Model
-
Sanwa Supply CHE-WD2 Cup Type Anemometer
-
Sanwa Supply LAN-TST6 LAN Cable Tester
-
Sanwa Supply CHE-TPHU2WN Digital Thermo-hygrometer With Heat Stroke & Display (With Warning Buzzer Setting Function)
-
Sanwa Supply CHE-TG220 Thermography (Infrared, Approx. 300,000 pixels, USB Rechargeable)
-
Sanwa Supply CHE-C1 Carbon Dioxide (CO2) Measuring Instrument (With Temperature / Humidity Meter)