Japan, SENSEZ
SENSEZ HLV-S6VL Compact Pressure Sensors

Products Made in Japan
 Manufacturer :SENSEZ
 Model :HLV-S6VL (HLVN-100KP,HLV-020KP,HLV-050KP,HLV-100KP,HLV-300KP,HLV-500KP,HLV-001MP,HLV-002MP,HLV-003MP,HLV-005MP)
Pressure sensor designed to operate on 3 to 5 VDC
Features
- Compact
- Low power
- Pressure sensor designed to operate on 3 to 5 VDC
- Low current consumption ideal for battery-powered sensors
- Pressure sensor with a welded structure that does not use an O-ring in the wetted part
- The wetted part is made of SUS316 or SUS316L that has high corrosion resistance. Support of a wide range of pressure media such as gas and medicinal solution
- Output signal of 0.1 to 1.1 VDC from a built-in amplifier circuit
Characteristics
- Low current consumption ideal for battery-powered sensors
- Pressure sensor with a welded structure that does not use an O-ring in the wetted part
- The wetted part is made of SUS316 or SUS316L that has high corrosion resistance.
- Support of a wide range of pressure media such as gas and medicinal solution
Specifications
- Accuracy:± 0.5% F.S. or less
- Output signal of 1 to 5 VDC or 4 to 20 mADC from a built-in amplifier circuit
- Overpressure:200% of the rated pressure
Use examples and track record
- Discharge pressure measurement for compressors
- Discharge pressure measurement for pumps
- Level measurement for open tanks
- Pressure control for pure water production devices
- Gas pressure measurement for refrigerators
- Filter clogging detection
Industries where our products are widely used
Precision equipment, semiconductors/liquid crystal, machinery, food/drug production, industrial material, etc.
| Model | Rated pressure | 
| HLVN-100KP | 0~−100kPa | 
| HLV-020KP | 0~20kPa | 
| HLV-050KP | 0~50kPa | 
| HLV-100KP | 0~100kPa | 
| HLV-300KP | 0~300kPa | 
| HLV-500KP | 0~500kPa | 
| HLV-001MP | 0~1MPa | 
| HLV-002MP | 0~2MPa | 
| HLV-003MP | 0~3MPa | 
| HLV-005MP | 0~5MPa | 
| Model | HLV-S6VL | ||||||||||
| N-100KP | -020KP | -050KP | -100KP | -300KP | -500KP | -600KP | -001 MP | -002 MP | -003 MP | 005MP | |
| Rated pressure * 1 | 0~-100kPa | 0~20kPa | 0~50kPa | 0~100kPa | 0~300kPa | 0~500kPa | 0〜600kPa | 0〜1MPa | 0〜2MPa | 0〜3MPa | 0〜5MPa | 
| Pressure type | Gauge pressure ※ 2 | Shield gauge pressure | |||||||||
| Overpressure | 200% of the rated pressure | ||||||||||
| Wetted part material | Diaphragm : SUS316L Pressure port: SUS316 | ||||||||||
| Sealing liquid | Silicone oil | ||||||||||
| Applicable media | Gas and fluid (media not damaging the wetted part material) | ||||||||||
| Power supply | 3 to 5VDC | ||||||||||
| Output | 0.1 to 1.1VDC | ||||||||||
| Current consumption | 2mA or less | ||||||||||
| Load resistance | 1k or more | ||||||||||
| Responsiveness | 5msec or less | ||||||||||
| Accuracy (linearity) | ±0.5% F.S. or less * 3 (±0.3% F.S. or less) | ||||||||||
| Temperature characteristics | ±0.05% F.S. / °C or less (0 to 60°C) | ||||||||||
| Compensated temperature range | O to 60°C | ||||||||||
| Operating temperature range | -20 to 80°C (no freezing allowed) | ||||||||||
| (Measurement medium temperature) | -20 to 100°C no freezing allowed | ||||||||||
| Operating humidity range | 35~85% RH (no dew condensation allowed) | ||||||||||
| Pressure connection port | R1/4 (standard) R3/8 R1/2 G1/4 G3/8 | ||||||||||
| Cable | 6 vinyl: 500mm / 2000mm (standard) Shield cable + atmospheric relief pipe (Excluding -003MP and -005MP) | ||||||||||
| Structure | IP65 | ||||||||||
| Insulation resistance | 100MQ or more / 500VDC | ||||||||||
| Withstand voltage | 500VAC, 1 minute | ||||||||||
| Vibration resistance | 98.1 m/s², 2 hours (X, Y, and Z directions) | ||||||||||
| Weight | Approx 200g | ||||||||||
| Impact of mounting orientation (port orientation changed from downward to sideways) | + 0.1% F.S. | + 0.5% F.S. | + 0.3% F.S | + 0.1% F.S. | _ | ||||||
- We also manufacture compound pressure sensors (gauge pressure of 500 kPa or less).
- Make sure that the operating vacuum pressure is 10 kPa abs or more. (Operating temperature range: 0-60℃)
- We also manufacture high-accuracy pressure sensors (accuracy: ± 0.25% F.S. or less).
Dimensions(Units:mm)

Cables / wires
| HLV | |
| Red | Power supply + | 
| White | Output | 
| Black | Common | 
| Atmospheric relief pipe | Gauge pressure available | 