Japan, Sika
Sika SC-PU1NB Architectural Sealant 1-Component Polyurethane Type
Product Made In Japan
Manufacturer: Sika
Model: SC-PU1NB
F-25LM-8020(PU-1) model with JSIA F★★★★★
It’s a high-performance, energy-saving model that can respond to the needs of the future of sealing technology, and it’s a vacuum pump in the semiconductor industry. It’s a product that has received a five-star energy-saving rating. Please do not hesitate to contact us for any inquiries or more detailed information.
Sealing Material Properties
Appearance | Paste Form | |||||
Performance based on San 8 45758 | Slump (01171) | Vertical | 5°C | 0 | ||
50°C | 0 | |||||
Slump (0101) | Horizontal | 5°C | 0 | |||
50°C | 0 | |||||
Elastic Recovery (%) | 94 | |||||
Adherend | Aluminum | |||||
Tensile Stress [N/mm^2] | 23°C | 0.1 | ||||
-20°C | 0.2 | |||||
Adhesiveness under Fixed Elongation | 23°C | NF | ||||
-20°C | NF | |||||
Adhesiveness after Compressive Heating and Tensile Cooling | NF | |||||
Adhesiveness after Artificial Light Exposure | ― | |||||
Adhesiveness under Fixed Elongation after Water Immersion | NF | |||||
Volume Loss (%) | 7.4 | |||||
Durability Classification | Equivalent to 8020 | |||||
Reference Properties | Shelf Life (Months) | 9 | ||||
Extrudability (Seconds) | 5°C | 7 | ||||
23°C | 3 | |||||
Curing Speed (Days) (Full cure at 5mm thickness) | Specification | Throughout the Year | ||||
5°C | 7 or more | |||||
23°C | 2 | |||||
35°C | 1.5 | |||||
Touch Dry Time (23°C – Hours) | Within 3 | |||||
Density (g/cm^3) | 1.4 | |||||
Type Tensile Adhesiveness | Adherend | Stress & Elongation Conditions | 50% Tensile Stress 1X1/0117)2 | Maximum Tensile Stress | Elongation at Maximum Load (%) | |
Aluminum | After Curing | 23°C | 0.14 | 1.20 | 1.000 | |
After Heating | 23°C | 0.12 | 1.00 | 980 | ||
After Water Immersion | 23°C | 0.10 | 0.80 | 750 | ||
Mortar | After Curing | 23°C | 0.14 | 0.80 | 850 | |
After Heating | 23°C | 0.12 | 0.82 | 760 | ||
After Water Immersion | 23°C | 0.10 | 0.72 | 740 |
A test result of “1” indicates that the product is not tested, and “NF” indicates that there is no damage.
The H-type tensile adhesion test is conducted in accordance with JIS A1439. The heating temperature “after heating” is the compression heating temperature of the durability test, and is 80℃ for products without durability classification. The results are representative values.
List of Suitable Materials for Appropriate Use
Working Joints | Curtain Wall | Metal Curtain Wall | Mullion Method | Glass Perimeter Joint | ||
Mullion-less Joint | ||||||
Panel Method | Panel Interval Joint | |||||
Glass Perimeter Joint | ||||||
PO Curtain Wall | Stone Pre-attachment, Tile Pre-attachment, Painting & Spraying | 「。バネル同目地 | ||||
Window Frame Perimeter Joint | ||||||
Glass Perimeter Joint | ||||||
Various Exterior Panels | Panel (Vertical Wall Locking, Horizontal Wall Anchor Method) | パネル間目地 Window Frame Perimeter Joint Joint with Clearance | With Painting | 〇 | ||
Without Painting | ||||||
Painted Aluminum Panel | Forced Drying, Applied Painting | バネル間目地 | ||||
Painted Steel Plate | Forced Drying, Baked Painting | バネル間目地 | ||||
Window Frame Perimeter Joint | ||||||
Enamel Steel Plate | バネル間目地 | |||||
Window Frame Perimeter Joint | ||||||
6^(3、Extruded Cement Board Joint Mark | バネル間目地 Window Frame Perimeter Joint | With Painting | ||||
Without Painting | ||||||
Metal Insulated Sandwich Panel | バネル問目地 | |||||
ガラス | Single Window | Glass Perimeter Joint | ||||
Continuous Windows | Glass Perimeter Joint | |||||
Glass Butt Joint | Glass Perimeter Joint | |||||
Metal Manufactured Ratio A | Fixture Perimeter | Drainage-Dish Plate Joint | ||||
Fixture Interval Joint | ||||||
Factory Seal | Sealing Material Receiver | |||||
Cap | Metal Cap | 笠木間目地 | ||||
Stone Cap | 笠木間目地 | |||||
笠木 | 笠木間目地 | |||||
Concrete Wall | Structural Slit | Structural Slit Joint | With Painting | |||
Without Painting | ||||||
Non-Working Joint | Festival Wall, Star Style/ | Struck Joint + Crack Induced Joint Window Frame Perimeter Joint | With Painting | 〇 | ||
Without Painting | ||||||
Wet Stone Paving Including Stone Joint | Stone Joint (Excluding Marble) | |||||
Marble Joint | ||||||
Window Frame Perimeter Joint | ||||||
Tile Backing | Tile Joint | |||||
Tile Undercarriage Joint | ||||||
Window Frame Perimeter Joint | ||||||
Public Exterior | Two Types of Panel | バネル間目地 | With Painting | 〇 | ||
Without Painting | ||||||
Various joints other than exterior walls | Rooftop | Sheet Waterproofing and Other Final Processing | ||||
Floor | Concrete | Slit Joint | ||||
Stone Paving & Tile Paving | Stone & Tile Joint | |||||
Panel and Raised Floor Panel Included | Same Panel Joint | |||||
Water Area | Bathroom & Bathtub | |||||
Kitchen Cabinet & Sink | ||||||
Washbasin Perimeter | ||||||
Drainage Outlet Perimeter & Through Pipe Perimeter | With Painting | 0 | ||||
Without Painting | ||||||
Column Base Perimeter etc. | With Painting | 0 | ||||
Without Painting | ||||||
Inner Wall (Partition) Joint | 〇 | |||||
Painting Completed Waterproof Material Base Treatment | 〇 |
Primer | N0.40 | |
Type | 1 – Urethane-based | |
Formaldehyde Emission Grade | Not specified | |
Appearance | Light yellow transparent | |
Main Components | Synthetic rubber, synthetic resin, silane coupling agent | |
Drying Time (minutes) | 59 | 60 or more |
20*0 | 30 or more | |
359 | 15 or more | |
Effective Time After Application (hours) | 8 | |
Effective Time After Opening (days) | Within the same day | |
Shelf Life (months) | 6 | |
Solvent Content | Ethyl acetate, butyl acetate | |
Main Usable Substrates | Aluminum, concrete |
※Notes:
●When installing the primer, be careful not to protrude or fly. Once completely cured, the primer will firmly adhere to the substrate and will not dissolve in organic solvents.
Please wipe it clean with a cloth soaked in toluene etc. as soon as possible on the day of construction. Please be aware that if you scrape or otherwise remove the adhesive after it has hardened, you may damage the underlying surface during removal.
Construction Procedure
1 Meeting before construction
Thoroughly consider the fit of the joints (shape and dimensions, secondary drainage treatment, construction conditions, etc.).
2 Preparation before construction
Please select materials, primers, auxiliary materials, and prepare construction instructions.
3.Inspection before construction
Please check the construction location, joint shape, dimensions and level differences.
Check for defects on the adherend (jumpers, chips, cracks, etc.) and repair as necessary.
4 Cleaning and drying the base
Check whether the adherend is sufficiently dry.
To prevent adhesion failure due to oil, dirt, dust, etc., carefully clean the surface to be adhered by wiping it dry and then wiping it with a clean cloth soaked in solvent.
Choose a cleaning solvent that can sufficiently remove oil, dirt, and other factors that inhibit adhesion from the adherend (such as methylcyclohexane). Please use n-hexane to dissolve the painted surface.
5 Loading backup material
Load backup material appropriate for the joint dimensions.
If there is not enough room for the depth of the joint, attach a bond breaker to the bottom to ensure two-sided adhesion. (For working joints)
6 Paste masking tape
Please be careful not to let the tape dig into the surface to which it is attached.
No adhesive remains, and the solvent used in the primer does not have a negative effect on adhesion. Use masking tape.
7 Primer application
Apply evenly with a brush to avoid uneven application.
Be careful when applying the primer so that it does not scatter or protrude.
Please ensure the specified drying time and fill the sealant within the effective time after application.
8 Filling with sealant
Consider the nozzle angle and filling speed so that sufficient pressure can be applied to the adherend using a nozzle that matches the width of the joint, and that it can fill to the bottom of the joint. 3 Inspection before construction
9 Spatula finish
After filling the sealant, finish it immediately with a spatula.
When finishing with a spatula, apply sufficient pressure to create a smooth finish.
10 Masking tape removal
The masking tape adhesive may transfer to the adherend, so please remove the masking tape immediately after filling.
11. Cleaning around the joints
12. Curing of sealant
13. Comprehensive inspection
*During construction, performance cannot be achieved unless materials are used appropriately. Please follow the construction procedures, etc. when handling.
Handling Precautions
This describes product performance under appropriate conditions and assuming proper storage, handling, and use. It merely describes general construction methods and procedures. The selection, storage, treatment and use of products, construction methods and procedures, etc. under the relevant construction conditions in individual and specific construction work are the responsibility of the construction contractor, who is an expert user.
Handling work
1 Wear protective gloves and an apron while handling.
2 When working in a closed room, ensure adequate ventilation.
3. Wear safety glasses, protective masks, etc. depending on the work situation.
4. Wash your hands and gargle thoroughly after handling.
5 Avoid direct skin contact.
6 Avoid contact with eyes.
7 Do not breathe vapor.
8 Do not swallow.
9 Please strictly refrain from smoking while using Hamatite.
10 Please cure without touching until hardened.
11 Please entrust waste disposal to an industrial waste disposal company.
First Aid
1 If it gets on your skin, immediately wipe it off with a rag and wash thoroughly with plenty of water and soap.
2 If itching or inflammation develops, consult a doctor immediately.
3 In case of contact with eyes, rinse thoroughly with clean water and consult an ophthalmologist immediately.
4 If you feel unwell after inhaling the vapor, immediately move to a place with fresh air.
5 If you experience any abnormalities such as a headache, please consult a doctor immediately.
6 If swallowed, drink plenty of water or milk, induce vomiting, and seek medical advice immediately.
Handling location
1 Never use the product near fire.
2. Install a local exhaust system in the handling area.
3 Keep out of reach of children.
Storage
1 Store tightly closed and indoors, away from direct sunlight, fire, moisture, and water.
2. Please use within the expiration date.
3 Please use up immediately after opening.
Prohibition Of Use For Other Purposes
This product is developed for architectural use. Please do not use it for any purpose other than this purpose. *Some of the Hamatite products listed in this catalog are toxic and flammable. Please refer to the Safety Data Sheet (SDS) for detailed information.
Note : Sika provides this information in good faith, based on current knowledge and experience, regarding the installation and use of our products. It assumes that products are stored, handled, and installed properly under normal conditions following Sika’s recommendations. This applies only to products intended for specific construction conditions mentioned in this document. If application conditions change, such as substrate alterations, or for different uses, please consult Sika’s Technical Service Department before using the product. Users should verify the product’s intended use or purpose.
Related Products
-
Super Tool SRB1924RZ Ratchet Wrench Double Size (All Polish Type, With Bent Spear)
-
Watanabe WCCT-005-K Small split CT
-
Hammer Caster 435S-WRB Rubber Wheel
-
Fuso Seiki Magic Cut E-Mist
-
Eagle Jack (Konno Corporation) KHN14-0.3WA Hydraulic Pump
-
Toho Seisakusho VVB-2712S. VVB-2712F Electric Ball 2-Way Control Valve