TASETO KEIKO CHECK Fluorescent Penetrant Inspection Materials

Product Made In Japan
Manufacturer: TASETO
Model: KEIKO CHECK

TASETO KEIKO CHECK, the fluorescent penetrant inspection material, detects any minute defects or flaws accurately.
KEIKO CHECK Inspection should be done under Black Light (ultraviolet lamp).
Three types of TASETO KEIKO CHECK, water washable, post emulsifiable, and solvent removable fluorescent types, are available.
The developer includes non-aqueous type, dry powder type, and aqueous type, and each has its advantages.

TypesSymbolsCharacteristicsApplications
Water washable penetrantN-21PHydrophobic typeFor smooth surface
L-2Higher sensitivity than N-21P.
N-180PWater based typeFor low-precision inspection
High sensitivity water washable penetrantN-2PHigh fluorescent brightness. Inspection is possible without a developer.General testing
N-3PHigher sensitivity than N-2P.Precision testing
N-4PHigher sensitivity than N-3P.High-precision testing
N-5PHigher sensitivity than N-4P.Ultra-high precision testing
Post emulsifiable penetrantAP-5 AP-6For precision inspection. Use AE-56 as emulsifier. Suitable for testing fine hair cracks.Ultra-high precision testing
EmulsifierAE-56Used with AP-5 or AP-6.For post emulsifiable fluorescent Penetrant
Non-aqueous developerFD-SLarge suction force of penetrant Quick drying.Partial testing of large-size parts.
Dry developerADD-456White fine dry powder.For detecting very fine flaws.
Wet developer (aqueous)ADW-456Used by dispersing white fine powder in water.Suit for penetrant testing equipment.

Packing units

420 ml aerosol (N-3P)
4-L can, 18-L can or 200-L drum
Fluorescent Penetrant Inspection Materials
TASETO KEIKO CHECK

Applications

Mass-produced small parts, threads, keyways, and other acute corners, and rough surfaces.

Features

1. Good fluorescent brightness and flaw detectability.
2. Usable with a variety of developers, thus widening the range of applications.
3. N-series fluorescent penetrants have self-developing action. Developers are not needed;
however, the use of a developer enhances the flaw detectability.
4. N-21P fluorescent penetrant is optimum for decreasing the drainage cost.

How to Use

Post emulsifiable fluorescent penetrant testing.

KEIKO CHECK

Water washable fluorescent penetrant testing.

KEIKO CHECK

Solvent removable fluorescent penetrant testing.

Key:
1. Pre-cleaning
2. Penetration
3. Emulsification
4. Rinsing (with water)
5. Drying
6. Dry powder developer application
7. Non-aqueous developer application
8. Wet developer application
9. Interpretation
10. Removal (with solvent remover)