Manufacturer: TECHNO ELECTRIC Co.,Ldt.
Model: ATS036T-Wxxx□
Features
- IEC/EN/UL 62368-1 & 60950-1
- 100-240VAC Universal Input
- Single Output to 36W
- Regulated Output With Low Ripple Noise
- Safety Agency Requirements and EMI/EMS Certified
- Private Label Marking Available
- Modified and Custom Design Available
- 1 Year Warranty
Green Mode
- CEC, DoE Level VI, Energy Star, ErP Stage 2, CoC Tier 2, NRCan & GEMS Level VI
- No Load Power Consumption Less Than 0.075W
Specification
Model |
O/P Voltage |
O/P Current |
Watt |
ATS036T-W050□ |
5.0V |
5.00A |
25W |
ATS036T-W075□ |
7.5V |
4.00A |
30W |
ATS036T-W085□ |
8.5V |
3.52A |
30W |
ATS036T-W090□ |
9.0V |
3.34A |
30W |
ATS036T-W120□ |
12.0V |
3.00A |
36W |
ATS036T-W121 |
12.0V |
2.50A |
30W |
ATS036T-W122U |
12.0V |
3.00A |
36W |
ATS036T-W123U |
12.0V |
2.50A |
30W |
ATS036T-W135□ |
13.5V |
2.66A |
36W |
ATS036T-W150□ |
15.0V |
2.40A |
36W |
ATS036T-W160□ |
16.0V |
2.25A |
36W |
ATS036T-W180□ |
18.0V |
2.00A |
36W |
ATS036T-W240□ |
24.0V |
1.50A |
36W |
ATS036T-W480 |
48.0V |
0.75A |
36W |
Parameter |
Specification |
Voltage |
100-240VAC |
Line Frequency |
50-60Hz |
Current |
1A Max. |
Protection |
Internal Primary Current Fuse |
Configuration |
U for US Plug |
|
E for EU Plug |
|
B for UK Plug |
|
A for AU Plug |
|
C for CN Plug |
|
V for Changeable Plug |
Output |
Specification |
Load Regulation |
±5% (Typical) |
Ripple & Noise |
2% Vp-p Max. for Output Voltage @ Full Load |
Transient Response |
0.5ms for 50% Load Change Typical |
Hold-up Time |
10ms @ Full Load |
Protection |
Short Circuit Protection / Over Voltage Protection / Over Current Protection |
DC Cord |
22AWG / 20AWG / 18AWG / 16AWG |
Ferrite Core |
No (Optional) |
Safety Approvals |
|
USA |
CB/UL/cUL/FCC/PSE/BSMI/LPS |
Europe & UK |
CB / CE / GS / LPS |
Australia |
CB / RCM / LPS |
China |
CB / CCC / LPS |
Electrical |
Specification |
Topology |
Switching Flyback |
Dielectric Withstand |
3000VAC Primary – Secondary |
Leakage Current |
0.25mA |
Efficiency |
DoE Level VI, Energy Star, ErP Stage 2, CoC Tier 2, NRCan & GEMS Level VI Certified |
EMC Standards |
EN55032, EN61000-3-2,3, EN55024 |
MTBF |
300,000 Calculated Hours at 25°C, by Telcordia SR-332 |
Environmental |
Specification |
Operating Temperature |
0 to +40°C |
Storage Temperature |
-20 to +80°C |
Relative Humidity |
Operating: 20 to 80% RH |
|
Storage: 10 to 90% RH |
Cooling |
Natural Convection Cooling |
Mechanical |
Specification |
Case Dimension |
U – L 79 x W 34 x H 74 (mm) |
|
U – L 75 x W 34 x H 71.4 (mm) (ATS036T-W122U & ATS036T-W123U) |
|
E – L 79 x W 34 x H 94 (mm) |
|
B – L 79 x W 49 x H 86 (mm) |
|
A – L 79 x W 41 x H 82 (mm) |
|
V – L 79 x W 35 x H 66 (mm) |
Weight |
160g (Ref.) |
|
180g (Ref.) (ATS036T-W122U & ATS036T-W123U) |