- Input: AC100V (AC90~132V)
- Remote control (RC) terminal
- Remote sensing (+S, -S) terminal
- Built-in OCP (Overcurrent Protection) and OVP (Overvoltage Protection) circuits
- UL standard compliant
Model name list
25W
Model name | Output Voltage | Output Current | |
---|---|---|---|
GXN-05005 | 5V | 5A | |
GXN-122R1 | 12V | 2.1A | |
GXN-151R6 | 15V | 1.6A | |
GXN-241R2 | 24V | 1.2A | |
GXN-480R5 | 48V | 0.5A |
50W
Model name | Output Voltage | Output Current | |
---|---|---|---|
GXN-05010 | 5V | 10A | |
GXN-124R2 | 12V | 4.2A | |
GXN-153R3 | 15V | 3.3A | |
GXN-242R5 | 24V | 2.5A | |
GXN-48001 | 48V | 1A |
100W
Model name | Output Voltage | Output Current | |
---|---|---|---|
GXN-05020 | 5V | 20A | |
GXN-128R4 | 12V | 8.4A | |
GXN-156R6 | 15V | 6.6A | |
GXN-24005 | 24V | 5A | |
GXN-48002 | 48V | 2A |
150W
Model name | Output Voltage | Output Current | |
---|---|---|---|
GXN-05030 | 5V | 30A | |
GXN-12012 | 12V | 12A | |
GXN-15010 | 15V | 10A | |
GXN-247R5 | 24V | 7.5A | |
GXN-483R7 | 48V | 3.7A |
Specification
Input | Number of phases | 1φ |
Rated input voltage and tolerance range | AC100V/(AC90V to AC132V), DC110V to 175V | |
frequency | 47Hz to 440Hz | |
efficiency | 75% (TYP) | |
Inrush current | 15A (TYP) (at rated input/output, +25℃) | |
Input Current | 1.4A (TYP) (at rated input/output, +25℃) | |
Noise Filter | Built-in | |
Output Conditions | Voltage Variable Range | ±10% |
Ripple Noise | Output voltage x 1.0% + 50mV P=P MAX (DC to 100MHz) | |
Input fluctuation | Output voltage x 0.4% MAX | |
Load Fluctuation | Output voltage x 0.8% MAX (0% to 100%) | |
Temperature coefficient | Output voltage x 0.02%/℃ MAX (0℃ to 50℃) | |
Drift | Output voltage x 0.5% + 15mV MAX (1H after power-on, 8H) | |
Retention time | 20mS MIN (TYP) (at rated input/output, +25℃) | |
Startup time | 100mS MAX (TYP) (at rated input/output, +25℃) | |
Additional Features | Overcurrent Protection | Drooping characteristics (automatic return) |
Overvoltage Protection | Built-in (squelch type) | |
Remote Control | (+RC, -RC) terminals: Output ON when open, output OFF when shorted | |
Remote Sensing | 100W and 150W only | |
General Terms | Temperature (operating/non-operating) |
Operating temperature: 0℃ to +71℃ Non-operating temperature: -20℃ to +85℃ (See instruction manual 2-10) |
Relative Humidity (operating/non-operating) |
30 to 80% RH (no condensation) | |
Dielectric strength Primary-secondary (at room temperature and humidity) Primary-case Secondary-case |
AC1500V 1 minute sensing current 10mA AC1500V 1 minute sensing current 10mA AC 500V 1 minute sensing current 10mA |
|
Insulation resistance Primary-Secondary (at normal temperature and humidity) Between cases |
50MΩMIN ( DC500V ) | |
Leakage Current | 1.0mA MAX | |
Structure | Vibration resistance | Total amplitude 0.5 mm, frequency 10 to 55 Hz, 1 minute cycle vibration in 3 directions for 2 hours each |