TECHNO ELECTRIC Co.,Ltd.
TECHNO ELECTRIC Standard Power Supply (PSK 50W 3 Outputs)

Manufacturer: TECHNO ELECTRIC Co.,Ldt.
Product name: Standard Power Supply (PSK 50W 3 Outputs)
Features
- Input: AC100V (AC90–132V)
- Safety Standard: UL Standard
- Independent Control Method for Each Channel
Specification
| Format name | PSK50-1212 | PSK50-1515 | |||||
|---|---|---|---|---|---|---|---|
| CH | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | |
| Rated Output Voltage | +5V | +12V | -12V | +5V | +15V | -15V | |
| Rated Output Current | 5A | 1A | 1A | 5A | 1A | 1A | |
| Total Output Capacity | 49W | 55W | |||||
| Weight | 0.5(kg) | ||||||
| Input conditions | Number of phases | 1φ | |||||
| Rated input voltage Tolerance | AC100V (AC90-132V) | ||||||
| frequency | 47Hz to 440Hz | ||||||
| efficiency | 70% (TYP) | ||||||
| Inrush current | 15A MAX (at rated input/output, +25℃) | ||||||
| Input Current | 1.3A (TYP) (at rated input/output, +25℃) | ||||||
| Noise Filter | Built-in | ||||||
| Output Conditions | Voltage Variable Range | CH1±10%, CH2,3 (fixed) deviation ±4% | |||||
| Ripple Noise | Output voltage x 1.0% + 50mV PP MAX (DC to 100MHz) | ||||||
| Input fluctuation | Output voltage x 04% | ||||||
| Load Fluctuation | Output voltage x 0.8% MAX (0% to 100%) | ||||||
| Temperature coefficient | Output voltage x 0.02%/℃ MAX (0℃~50℃) | ||||||
| Drift | Output voltage x 0.5% + 15mV MAX (1H after power-on, 8H) | ||||||
| Retention time | 20mS MIN ((at rated input/output, +25℃) | ||||||
| Startup time | 200mS MAX (at rated input/output, +25℃) | ||||||
| Additional Features | Overcurrent Protection | Drooping characteristics (automatic return) | |||||
| Overvoltage Protection | Clover limiter type (CH1)/Zener limiter type (CH2/CH3) | ||||||
| Remote Control | – | ||||||
| Remote Sensing | – | ||||||
| General Terms | Temperature Operating Non-operating | 0℃~+71℃ -20℃~+85℃ | |||||
| Relative Humidity Operating Non-operating | 30 to 85% RH (no condensation) 30 to 95% RH (no condensation) | ||||||
Dielectric strength: Primary-secondary | AC1500V 1 minute sensing current 10mA AC1500V 1 minute sensing current 10mA AC500V 1 minute sensing current 10mA | ||||||
| Insulation resistance: Between primary and secondary (normal temperature and humidity) cases | 50MΩ MIN (DC500V) | ||||||
| Leakage Current | 1.0mA MAX | ||||||
| structure | Vibration resistance | Total amplitude 0.5 mm, frequency 10 to 55 Hz, 1 minute cycle vibration in 3 directions for 2 hours each | |||||

Related Products
-

TECHNO ELECTRIC ATM210T-Fxxx AC Adapter I.T.E. / Medical Open Frame Power Supply 210 Watt Series
-

TECHNO ELECTRIC ATS012S-WxxxU AC Adapter 12 Watt Series
-

TECHNO ELECTRIC ATS024T AC Adapter 24 Watt Series
-

TECHNO ELECTRIC Custom Power Supply for Medical Equipment 3
-

TECHNO ELECTRIC Standard Power Supply (PSK 30W 2 Outputs)
-

TECHNO ELECTRIC ATS018T AC Adapter 18 Watt Series