Three S X Series Pneumatic: XP

Manufacturer: Three S Co., Ltd.
Model : X Series

Features

Cam action and characteristics are selectable

Value action can be switched between direct and reverse by shifting 90[deg] the position of the feedback lever A from A to B.(However the output piping has to be changed.) Also, the structure is such that the characteristics can be changed by selecting the cam. For linear motion, the standard cam can be used to select the characteristics of linear and equal %. Select any of these rotary motion, change the cam to obtain proper equal % characteristics, square-law characteristics, and equal reverse % (optional).

Model

型式12345a5b678910
□□□○/□○□○□○□○□□○○
seriessupplemental
1
model
2
series
3
construction
4
function &connection
5a
*1 Ambient Temp.
5b
Mounting
1100 series0standard1Rc(PT)1/4 single actingSstandard:-20 to 83℃S1Linear motion / Side lever type
XPP/P2Rc(PT)1/4 double actingS3Rotary motion / Linkage lever type
3NPT 1/4 Single actingB4Linear motion / Back lever type
4NPT 1/4 double actingB7Concentric rotary motion / Back lever type
5Rc(PT)1/4 w/ signal transmitterL-50~60℃
6NPT 1/4 w/ signal transmitterH0~100℃

2 phase /Eq%D○○direct lever connection type w/ clump

supplemental
6
*2 pressure gauge (output pressure)
7
pilot relay / orifice
8
input signal
9
cam
10
lever and clump
M20.2MpastandardC1alinear motion / 45
4 phase linear / Eq%
L○○Linear motion / Side lever type
multi step lever connection type w/ clump
M40.4Mpacleanerorifice diaC3LRotary moton / Linkage lever type / 90
2 phase / linear
l○○multi step lever connection type w/o clump
M01.0Mpaw/ow/C3E
K2200kPaF1Q15.0C3BRotary motion / Linkage lever
ー/90
2 phase / square-law
d○○direct lever connection w/o clump
K4400kPaF2Q22.0(STD)C3PRotary motion / Linkage lever type
ー/90
2 phase / reverse Eq%
K○○Rotary motion / Linkage lever type w/ clump
K01000kPaF4Q41.0C4LaLinear motion
/45
4 phase / linear
k○○Linkage connection w/o clump
P2 *330psiF5Q50.7B120~100kPaC7LConcentric rotary motion / Back lever type
/90
2 phase / linear
H○○Linear motion / Back lever type L type lever connection w/ clump
P4 *360psiF6Q60.45B220~60kPah○○L type lever connection w/o clump
P0 *3150psistableB360~100kPaV○○Concentric rotary motion / Back lever type
Concentric rotary connection / M8 screw connection
B22barG1J15.0
B44barG2J22.0(STD)
B010barG4J41.0
G5J50.7
G6J60.45
fast
R1T15.0
scrollable

* Model notation written in blue letters are standard model, others are option.

*1 flameproof model is S type only.
*2 please contact us for psi and bar display.
*3 No domestic sales in japan due to Non-SI unit.

Specicfication

SpecsSingle actingdouble acting
Input signal (pressure)standard: 20 to 100 kPa 

(1/2 split range is available with easy adjustment)

supply air pressure0.14~0.7MPa/140~700kPa
stroke / angleLinear motion : 10~100mm 

Rotary motion : 60°~90°

Air connection (pressure gauge connection)Standard: Rc 1/4(pressure gauge Rc 1/8) 

Option: NPT 1/4(pressure gauge NPT 1/8)

*1
pressure gauge
(output pressure)
Stadard: 0~0.2MPa、0~0.4MPa、0~1.0MPa (R)
Option: kPa、psi、bar (R, NPT)
ConstrucionNon-explosion proof
CamStandard: Linear characteristics 

Option: non-linear characteristics

Ambient Temp.Standard: (S) -20~83℃ 

Low temp. construction: (L) -50~60℃

High temp. construction: (H) 0~100℃

Weightapprox. 1.3kgapprox. 1.4kg
MaterialsBody: Aluminum diecastings (Special Anodize) 

Cover: PBT resin(Mixed glass fiber)、Option: Aluminum diecastings (Special Anodize)

*1 please contact us for psi and bar display

characteristicsSingle actingDouble acting
Linearity±1.0%F.S±2.0%F.S
hysteresis1.0%F.S1.0%F.S
repeatability0.3%F.S0.5%F.S
sensitivity0.2%F.S0.5%F.S
change of supply pressure0.2%/0.01MPa0.3%/0.01MPa
orientation effect (10deg / 90deg)0.2% / 4.0%
endurance to vibration1%/1G
air consumption(Nl/min)
(Nl/min)
5.0/0.14MPa
at 50% output pressure
10/0.4MPa
at 75% output pressure
Max Cv (Nl/min)
(Nl/min)
160/0.14MPa370/0.4MPa
on condition that Output is open to air (orifce dia 5mm)
Pilot RelayMax Cv.
(Nl/min)
Air Consumption
(Nl/min)
single acting
(0.14MPa)
double acting
(0.4MPa)
XEXPXEXP
Standard1603705.05.01010
Stable1603707.08.01416
Fast1804507.08.01416

Specifications above is effected by actuator spec

pneumatic instrument / precautions

* clean dry air (dew point – 30℃ or below) is required.

 air filter (mesh 5μm or less) is required.

REQUEST QUOTATION