Tohkemy DulcoFlow Pump Accessories

 

Manufacturer: Tohkemy Corporation
Model: DulcoFlow

Features

The Dalco Flow DFMa ultrasonic flow meter accurately measures liquid output specifically for metering pumps.
It is possible to specify the instantaneous flow rate and integrated flow rate, and output the instantaneous flow rate as a pulse signal or analog signal.
Integrating the Dalco Flow unit with select ProMinent metering pump models establishes a closed-loop feedback system. By transmitting continuous flow measurements directly to the pump controller, the system automatically dynamically adjusts stroke frequency to regulate fluid discharge with high precision.
Models that support feedback control
Gamma X
Gamma XL (Delta)
Sigma control, etc.
Please contact us for details.
Mechanism

An ultrasonic flowmeter that uses the pulsation peculiar to a metering pump.
– Measurement is possible even if there is a large flow, pulsation, dirt on the liquid, _or viscosity.
– No metal is used in the wetted parts, _and even low-conductivity liquids can be measured.
* However, it cannot be measured in the case of non-pulsating flow, mixed turbidity, _or mixed air bubbles.

specification

ModelDFMa 05DFMa 08
Measurement range0.1 – 13.0 L/h0.6 – 50.0 L/h
Detectable flow range0.03 – 10.0 ml/Stroke (discharge amount for each pump stroke)
accuracy±2% (100 strokes _or more) However, it may be affected by the properties of the measuring solution.
Withstand voltage0.15 – 1.6 MPa
Allowable liquid temperature-10 to +45 degrees No freezing
Wet contact materialPVDF (seal FPM / EPDM / PTFE included)
Body materialPPE + GF20 (Screws are SUS304)
Output specifications(option)Analog output: 0/4 to 20mA DC x 1 (load resistance 400Ω (insulation))
Pulse output: 1 pulse / stroke
Frequency output : < 10kHz
Power supply specificationsSingle-phase 100-230VAC ± 10% 50 / 60Hz
Ambient temperature / protection class-10 to + 50 ° C Humidity 95% _or less / IP65 equivalent (indoor specifications)
Dimensions / massW121×H160×D122mm / about 0.8kg

Measurement target

Water, Hydrogen peroxide, Sulfuric acid, Sodium hypochlorite (soda), Hydrochloric acid, Aluminum sulfate
Chemical solution / condition that cannot be measured
Chemicals containing air bubbles and slurries
Measurement error will increase.
Emulsified chemicals
Measurement error will increase.
Caustic soda (sodium hydroxide)
Since ultrasonic transmission is difficult, measurement error becomes large.
Other chemicals that are difficult to transmit ultrasonic waves
If you do not have a track record, we recommend that you perform a test in advance.