Japan, Tokyo Keiso
Tokyo Keiso SFC017 Converter for UCUF ultrasonic flowmeter
Made in Japan
Manufacturer: Tokyo Keiso
Model: SFC017
The UCUF (Ultra-Clean Ultrasonic Flowmeter) series Ultrasonic Flowmeter is designed for very low flow rate applications. The nonwetted Sensor design, constructed of specific grade PFA material, makes the UCUF Series an ideal choice for semiconductor industry, where extreme cleanness of pipe line inside is of primary importance. The SFC017 is used as a converter for UCUF series ultrasonic flowmeters. Using state-of-art signal processing technology, this converter offers stable flow measurement by minimizing adverse effects caused by the bubbles contained in the flow liquids. Thus, it has achieved the reliable flow measurement of semiconductor manufacturing process and chemical liquids handling process. Furthermore, the stability of flow measurement at low flow rate has been improved significantly by the upgrading of time resolution and high speed signal processing compared to the existing products.
Features
- New signal processing has improved anti- bubbles capability of converter.
Normally, ultrasonic flowmeter has difficulty in measuring fluid containing bubbles, because the bubbles interfere with ultrasonic signal passage.
In virtue of DSP and accumulated field experience, anti-bubbles capability has been remarkably improved. - Compact and light weight
The detector and the converter are of separate type.
Compact and easy wiring because of the plug-in construction of the converter. - Coaxial connector
General purpose BNC coaxial connector common to existing products - Cleared EMC test conforming to EN61326-1: 2006
- Lead free compatible
- Optimal measurement because of zero adjustment before Suring
- Measurement of high kinetic viscosity liquids as high as 40mm²/s Ideal detector with clean construction
- Corrosion resistant and easy installation
- Accuracy: within ±1% of the reading at flow velocity 1m/s or more
- Versatile functions including followings
Alarm outputs of instantaneous flow rate or fault status output
Various analog outputs of instantaneous flow rate are selectable
Specifications
Model | SFC017 |
---|---|
Applicable detectors | UCUF-04MB, UCUF-04K, UCUF-06K |
Measuring fluid | Liquids |
Fluid temperature | 10 to 60°C(Consult us about 61°C or more.) |
Fluid sound speed | 1000 to 2200m/s |
Fluid kinematic viscosity | 0.3 to 40mm²/s |
Flow range | Min.: 0 to 0.05 L/min, Max.: 0 to 8.0 L/min |
Input | Min.: 0 to 0.05 L/min, Max.: 0 to 8.0 L/min |
Pulse output | Either frequency pulse output or fault output is selectable ·Frequency pulse output Open collector pulse Load rating: Within DC30V, 15mA Pulse width: Duty 1 : 1 Pulse rate: 0 to 1000Hz (Full scale)·FAULT output (Output will be made if abnormalities occur in converter or detector.) Open collector pulse Load rating: Within DC30V, 15mA |
Alarm output | High or Low alarm (2 points) Open collector pulse Load rating: Within DC30V, 15mA |
Current output | DC4 to 20mA Load resistance: Within 500Ω |
Low flow cutoff | 0 to 25 %F.S. |
Communication function |
RS485 communication function, Protocol: MODBUS Up to 32 units can be connected |
Power supply | 24V DC ± 10 %, 110mA or lower |
Enclosure | IP20 (Indoor use) |
Installation | DIN rail installation |