Tosoku RE29 Series Ultra Slimline Rotary Encoder with Push Switch

Product Made in Japan
Manufacturer: Tosoku
Model: RE29 Series

RE29 series pack compact rotary encoder with dual-functional resin shaft into the space-saving resin enclosure.
RE29 is recommended for wide range of machines including measurement components, medical and telecommunication devices.

Features

● Extremely thin (6.6mm) and lightweight (7g)
● Multi-functional with 2-way acting – push switch function and rotating function – shaft
● Eco-friendly:
1) Low cost and lesser parts by VA design
2) RoHS compliant
● Designed to be soldered to the printed circuit board

Specifications

1. Electrical and Mechanical specifications
ItemsRated Value
Rotary EncoderNumber of Pulses6 PPR
Number of Clicks24 Clicks
Supply VoltageDC3.3V ± 5% ≦ 20mA 6mA TYP
DC5V ± 5% ≦ 10mA 4mA TYP
Output SignalsChannel A/B: Square Wave CMOS chip
Output VoltageHigh(Supply Voltage - 2.5V) ≦
Low≦ 0.5V
Response Frequency100Hz
Rotational Torque4 ± 2 mN・m

Push switch

Rating of contact≦ DC12V 0.1 ~ 10mA (Resistance load)
Travel of switch0.2 ± 0.1 mm
Operational Force5 ± 2 N
Weight7g
2. Reliability and Environmental Specifications
ItemsRated Value

Durability of operating area

Thrust directionPush100N
Pull50N
Radial1N・m
Rotational durability1 million strokes (No load)
Screw TorqueNot more than 1N・m
Heat resistance of solderSolder bit temp.: MAX 350℃Within 3 seconds for each terminal
Operating temperature-0℃ ~ +55℃
32F ~ 131F
Storage temperature-40℃ ~ +85℃
-40F ~ 185F

Output Waveform

1) Turning the shaft clockwise will generate the signal A when the signal B outputs a low voltage (0);
2) Rotating the shaft counter-clockwise will generate the signal A when the signal B outputs a high voltage(1);
3) Either signal A or B switches from 0→1 or 1→0 for every single click (Quad edge evaluation spec).

Part Number Designation

Dimensions (mm)

PWB mounting hole dimensions (mm)

Circuitry

Warranty

● 1 year from the date of shipment

Precautions

WiringUse buffering amplifier when extending lead wire over 30cm.
SolderingDo not put a load on the terminal area during and immediately after soldering.
OperationDo not use flow/reflow soldering machines.
PowerUse under specified power voltage and connect properly.