TOYO KEIKI DS-5A Non-indicating Voltage Relay for DC Voltage

Product Made In Japan
Manufacturer: Toyo Keiki
Model: DS-5A

Overview

This non-indicating voltage relay detects the voltage of DC power supplies. It can detect both H and L in detected voltage setting ranges, enabling safe operating even with voltages that contain ripples, such as those in rectified power supplies.

Features

Driver adjusts type enables easy and accurate configuration of voltage settings.
Safe operation even for voltages containing ripples.
3 different attachment methods.
Front attachment (attachment to the terminal block or rear connection socket on 8P) Rear attachment

Purposes

Voltage detection in DC power supplies
Voltage detection in rectified power supplies
Automatic control

Specifications

(1) Detection Method
(2) Detected Voltage Rating

Voltage comparison-based voltage detection

Model Setting Range for Detected Voltage Series Resistor Note) Power Consumption (W) Note
L H Detection Side Operation Side
DS-5A-24A 20-24V 24-28V Inside Dimensions 0.2 1.5
DS-5A-48A 40-48V 48-56V 0.4 1.5
DS-5A-100A 80-95V 105-120V Externally connected for operation 1.1 5.0
DS-5A-U12 1O-14V 10-14V Both the operation unit and the detection unit are externally attached if the setting range is exceeded 0.1 2.0 Scale of general purpose model is 0*100%
DS-5A-U24A 20-28V 20-28V 0.2 1.5
DS-5A-U48A 40-56V 40-56V 0.5 1.5

Note 1. Power Consumption (operation at maximum voltage on maximum setting, where L = OFF and H = ON)
Note 2. DS-5A-U□ (A) indicates all-purpose model. Be sure to connect a series resistor if the values in this table
will be exceeded. (Calculation method for series resistors can be found on P20.)

(3) Detection Error

Within ±1.5% of upper limit setting maximum voltage value (within ±2.5% for DS-5A-U12).

(4) Set Method

VR variance by driver adjustment.

(5) Contact Capacity

DC 30V/1A (resistance load), AC 100V/1A

(6) Contact Arrangement

L side: 1b, H side: 1a

(7) Relay Contact Output

(8) Retained Range

Within ±1.5% of upper limit setting maximum voltage (within ±2.0% for DS-5A-U12)

(9) Reaction Time

200mS or less when 97% to 110% of set voltage is applied

(10) Operation Frequency

20 times per 60 seconds, 10 minute stop

(11) Overvoltage Strength

(When upper limit setting maximum voltage value is 100%) Continuous overvoltage of 120% possible with all models) 150% possible for 3 minutes on all models; 200% not possible on any models.

(12) Detection Input Ripples

Within 20% P-P

(13) Operating Temperature Limits

Insulation Test  Between Electrical Circuit and Case: DC500V mega 10MΩ or higher
Between Electrical Circuit and Relay Contact: DC500V mega 5MΩ or higher
Voltage Test      Between Electrical Circuit and Case: AC 2000V (50/60Hz per minute)
Between Electrical Circuit and Relay Contact: AC500V (50/60Hz per minute)

(14) Pin Layout Diagram

Outside Dimensions

Attachment Diagram

Series Resistor Calculation Method for General-Purpose Detector Side and Operation Side

(1) Pin Layout Diagram

(2) Calculation Method for RH or RL Series Resistor for Detection Side (Externally Connected)

(A) Reference Current The reference current is indicated as a bond.

Model Name Reference Current I0 (mA) Vu (V)
DS-5A-U12 1.75 12
DS-5A-U24A 2.86 24
DS-5A-U48A 3.33 48

(b) Calculation

(c) Example Calculation

Model Name Set Voltage Range (V) Vo (V) Detection Side Multiplier RH or RL Value
DS-5A-U12 22~26 24
(24-12) [V] / 1.75 [mA] =6.86 [kΩ]
DS-5A-U24A 44~52 48
(48-24) [V] / 2.86 [mA] =8.39 [kΩ]
DS-5A-U48A 92~108 100
(100-48) [V] / 3.33 [mA] =15.6 [kΩ]

(3) Calculation Method for R Series Resistor for Operation Power Supply Side (Externally Connected)

Use the equation below to calculate the current I in the input voltage range, then decide on the value for the R series resistor to be connected to the operational power supply.
The current I value is for cases in which both the H and L sides are excited by the load relay of the non-indicating voltage relay (L: OFF, H: ON).

Caution

Model Name Input Voltage (Voltage of Auxiliary Power Supply) Range E [V] and Resistance Value R of Multiplier on Auxiliary Power Supply Side [kΩ] Note
DS-5A-U12
80mA ≤ I = E – 6 / R + 0.086 ≤ 140mA
Vz=6V
RD=0.086kΩ

 

DS-5A-U24A
25mA ≤ I = E – 12 / R + 0.4 ≤ 70mA
Vz=12V
RD=0.4kΩ

 

DS-5A-U48A
15mA ≤ I = E – 24 / R + 1.36 ≤ 35mA
Vz=24V
RD=1.36kΩ

 

Emax: Maximum voltage of auxiliary power supply, Imax: Maximum current
Emin: Minimum voltage of auxiliary power supply, Imin: Minimum current
Select R within the range where the above inequality is achieved.
If the inequality is not achieved for I, rework the equation by methods such as raising the R value or narrowing the voltage range of the power supply.
(Note) Settings can be congured in the desired position between 0 and 100% for both H and L.

Scale Drawing

Connection Circuit Diagram of the External Circuits

(1) The detection input and auxiliary power supply input are COM and +.
(2) If the detection input and the auxiliary power supply are the same, connect the auxiliary power supply terminal (7) and the detection input (8) (8 and 2 for U shape) as shown in the diagram below.

(3) If the detection input and the auxiliary power supply are separate, connect them as shown in the diagram below.

Precautions for External Connections

●Do not connect with the polarities of the detection input and auxiliary power supply opposing each other.

 

REQUEST QUOTATION

PAYMENT

payment-methods

 

TOOLS & EQUIPMENT

Lifting
Eagle Clamp | Eagle Jack | Elephant | Endo Kogyo
Japan Clamp | Kanetec | Jung | KITO | Katsuyama Kikai
Kondotec | Miki Netsuren | Sanei Seiki | Taiyo

Hand Tools
Bix | Miyakawa | Nakatani Kikai | Ogura | Osakada Tool
Super Tool | TONE | Yutani

Tape
Kamoi | Kikusui | Misuzu | Nirei | Okamoto | Taiho | Teraoka

Measurement
Hasegawa | Kawaki | Kett | KGK | Line Seiki | Nagano Keiki
Niigata Seiki | Obishi Keiki | RSK | Ryoden Shonan | Sanko
Sanwa Supply | Showa Seisakusho | Showa Sokki
SK Sato | Tokyo Keiso | Tokyo Sokushin

Safety Tools
Fujii Denko | Shigematsu | Titan

Welding
Asahi Weldex | Daihen | Koike | Nissan Tanaka

Drilling
Dijet | Kansai Kogu | Nitto Kohki | Okazaki Seiko | Takeda

Chemical
Cemedine | DaitoNippon Grease | Taseto

Other Tools
Hammer Caster | Kitagawa | Matsuda Seiki | Misuz | Sanritsu
Sanyutec | Shizuoka Seiki | Toyo Kensetsu Kohki | Yamamoto
Yamari

PLANT FACILITIES

Facilities
Acokk | Bunkaboeki | Horiuchi | Konan | Murakoshi
Murakoshi Industries | Nesstech | Nihon Flux | Nikkin Flux
NFK | Omega System | Organo | Taiyo Parker | Toyo Mic

Pump
Dynaflo | Ebara | Honda Kiko | KyowaMusashino
Tsurumi

Valve
Astam | Kyowa Iron | Nachi | Nippon Daiya | Sawada
Wasino Kiki | Yoshitake

Electricity
Arkon | Asahi Bagnal | Gentos | Iwasaki | Kokosha | U_RD

CONSTRUCTION

Concrete Work
Daia | EXEN | Japan Life | Mikasa | Okasan Kiko | Taiheiyo

Railway Work
Kyoei | Sanwa Tekki | Teikoku | Toko

Scaffolding
Bullman | Okabe | Rikiman | Tsugaru

High Tension Bolt
Dong Ah | KPF | Nippon Steel Bolten | Nippon Fastener

Bolt & Nut & Washer
Hard Lock | Kishu Fastener | Matsukin | Mori Kozai
Nakaumi | Naniwa | Ogawa | Otani | Sudo | Toneji

STEEL MATERIAL

Steel & other Material
Dongil | JIS Standard | DSR | Sumitomo Wire | Winoa IKK

Pipe
Benkan

Return Top