Toyo Keiki
Toyo Keiki DVF-11M DC Voltmeter Moving-coil Type
Product Made In Japan
Manufacturer: Toyo Keiki
Model: DVF-11M
Features
1. A long scale meter for indicating wide angles.
2. A stepped scale plate removes any level difference between the scale and the tip of the needle, resulting in accurate readings.
3. Meter that has a bright scale due to the wide-cover lighting surface.
4. It is not affected by steel panels.
5. Can be manufactured with EL board (Electro-Luminescence Board) lighting.
6. The terminal cover is now equipped as standard.
7. It is now compatible with multi-setting set pointer models.
Specification
Measurement Range Value | DVF-11M | Note | |
---|---|---|---|
Consumption Current | Series Resistor | ||
1 V
1.5 V 3 V 5 V 7.5 V 10 V 15 V 30 V 50 V 75 V 100 V 150 V 300 V 500 V (600V) 750 V 1 kV 1.5 kV 2 kV 3 kV 4 kV 5 kV 7 .5 kV |
1mA | Built-in | Voltage Division Type Series Resistor |
M-2B | |||
M-3 | |||
M-4A | |||
M-6 | |||
Weight | Approx. 0.45kg |
* Series resistors than 600V are built in.
* M-2A type series resistors that exceed 600V but are less than 750V are externally connected.
(Series connection, 1mA consumption current)
* The JIS mark cannot be displayed for specifications that exceed 600V.
Remarks
Connection to Series Resistor
1. Meters over 750V must be connected with the voltage division type series resistor specified in the table to the left as shown in the figure below.
Note) M-6 series resistors must be connected to the earth using the G terminal.
The G terminal is only available on the M-6 series resistor.
There is no G terminal on other series resistors because the boxes are made of resin.
2. See P.25 for details on the outside dimensions of the series resistors.
Meter Sensitivity
The meter sensitivity of DV voltmeters is 1mA (1kΩ/V) as standard.
Zero-center meters and multiple-scale meters can also be manufactured
Meter Input for Reception Meter | DVF-11M | Note | |
---|---|---|---|
Consumption Current | Series Resistor | ||
1~5V | 1mA | Built-in | Internal Resistance: 5kO |
Weight | Approx. 0.45kg |
Outside Dimensions Note
Connection Diagram Note
For a built-in series resistor (If 600V or below)
For an externally connected voltage division type series resistor (Over 750V)
Related Products
-
TOYO KEIKI GP and HP Series Temperature Transducer
-
Toyo Keiki CF Series DC Voltmeter Moving-coil Type
-
Toyo Keiki CF Series AC Ammeter Rectifier Type
-
Toyo Keiki AVF-11M AC Voltmeter Moving-iron Type R.M.S.-Response
-
TOYO KEIKI MPV-11 and MPC-12 Earth-resistance Meter Relay
-
TOYO KEIKI EGM Series Watt Transducer