Toyo Keiki
TOYO KEIKI EGP Series DC-Pulse Transducer
Product Made In Japan
Manufacturer: Toyo Keiki
Model: EGP Series
EGP-□ : A signal transducer that outputs a frequency
pulse signal in proportion to analog signals.
Plug-in type makes upkeep and changes in configuration simple.
By using a high-pressure semiconductor relay it is possible to drive a current of AC 200V.
Photo couple provides complete insulation between input and output.
Specification
INPUT | OUTPUT | AUXILIARY POWER SUPPLY | |
---|---|---|---|
8 standard types of input are available
Available with |
5 standard types of output are available
Available with output |
AC 100/110V ±10% 50/60Hz approx. 3.5 VA AC 200/220V ±10% 50/60Hz approx. 3.5 VA DC 24V ±10% approx. 3 W Types are immediately available. |
TYPE OF OUTPUT SIGNAL | ATTENTION |
---|---|
Two types of output are available • Non-electrical contact output • Electrical pulse output |
An output signal of fixed pulse width is generated without regard to the input signal. Output range ceiling values below 10Hz: approx 50mS. Output frange ceiling values over 10Hz: 1/2 the ceiling value cycle. Output cutoff: At an input range lower limit of less than approx.2% output will be shut off. Output protection: Output circuits are equipped with surge absorbers, however, under inductive loading use a device such as a clamp diode or snubber to limit spikes in the current. |
Specified Character
(1) Tolerance
±0.5% of output span. (Ambient temperature 23 ℃)
(2) Effect of temperature
Within ±0.5% of output span. (For 23 ℃±10℃ variations)
(3) Effect of auxiliary power supply
Within ±0.25% of output span. (For rated voltage ±10% variations)
(4) Dielectric strength
2000V AC,1min.(50/60Hz)
(Between signal circuit,auxiliary power supply and externel case)
1500V AC,1min.(50/60Hz)
(Between input and output)
(5) Insulation resistance
Higher than 100MΩ at 500V megger.
(Between input,output,auxiliary power supply and external case)
(6) Weight
Approx. 410g
Connection Diagram
Designation Item at Oder
ORDER EXAMPLE
① EGP-1-1-21
② DGP-2-9-92 INPUT : DC 0~5mA, OUTPUT : 0~50Hz
※For special specifications please consult company representatives
Related Products
-
TOYO KEIKI TGP Series rpm Transducer
-
TOYO KEIKI GP and HP Series Voltage Transducer
-
Toyo Keiki CF Series DC Voltmeter Moving-coil Type
-
TOYO KEIKI GP and HP Series Watt Transducer
-
Toyo Keiki EVF-11M-RVF-11M Wattmeter and Varmeter Electronic Device Type Time Sharing Multiplication Method
-
Toyo Keiki TMW Series Multi Power Meter