CGP-□: As a temperature sensor the resistance temperature detector is a temperature-DC conversion device.
Generous input specifications. ・From -200℃ to +500℃.
Photo couple provides complete insulation between input and output-the influence of common mode noise is excluded and stable operation is ensured (AC 2000V,1 min.).
Linearizer is standard. ・Linearity below±0.2%.
The influence of connecting cables is excluded. -Resistance temperature detector drives a constant, the type of measurement errors that are caused by the use of a connecting cable do not happen.
It was equipped with a burnout function. ・Sensor circuit failure immediately detected and output.
Plug-in type makes upkeep and configuration changes simple.

Specification

INPUT OUTPUT AUXILIARY POWER SUPPLY
Platinum resistance temperature detector, 3-lead type: Pt100Ω, JPt100Ω. Standard six bands of measured temperature range. Regulated sensor current: DC 2mA 8 standard type of output are available. Burnout: Upper AC 100/110V ±10% 50/60Hz approx. 3 VA
AC 200/220V ±10% 50/60Hz approx. 3 VA
DC 24V ±10% approx. 3 W
DC 100/110V ±10% approx. 3.5 W
DC 48V (38-62V) approx. 3 Wtypes are immediately available. For types not listed above contact a company representative.
Available resistance temperature detectors Platinum(Pt, JPt)100Ω (0°C)
-input span of over 50 °C
When resistance temperature detectors not conforming to JISC 1604-1997 are specified please indicate the resistance line curve.
Available with Max. voltage output 10V (600Ω~∞)
Max. current output 20mA (0-550Ω)
The burnout value may be lowered according to your needs.

Connection Diagram

Specified Character

(1) Available resistance temperture detectors
Platinum(Pt,JPt)100Ω -input apan of over 50℃
Platinum(Pt)50Ω -input span of over 100℃
at JIS C 1604-1997(resistance temperature detector)
As well as nickel,platinum-cobalt,and copper resistance tempereture
detectors that conform to JIS C 1604-1997 are also available;
please contact a company representative and explain your need.
Input system 3-lead type (permissible line resistance,200Ω per lead)
(2) Regulated sensor current
DC 2mA
(3) Tolerance
±0.5% of output span.(Ambient temperature 23℃)
(4) Effect of temperature
Within ±0.2% of output span. (For 23℃±10℃ variations)
(5)Effect of auxiliary power supply
Within ±0.1% of output span. (For rated voltage ±10℃ variations)
(6)Effect of load resistance
Within ±0.05% of output span. (For load resistance range)
(7) Output ripple
Within 0.5%p-p of output span.
(8) Response time
Shorter than 0.5sec. (Time to 99% output)
(9) Dielectric strength
2000V AC,1min.(50/60Hz) (Between input,output,auxiliary power supply and external case)
(10) Insulation resistance
Higher than 100MΩ at 500V megger. (Between input,output,auxiliary power supply and external case)
(11) Built-in Functions
Isolation (photo-couple method)-standard
Linearizer (linearity within±0.2%)-standard
Burnuot function-In the standard specification burnout is set for when the following upper limit is exceeded:when the
output value=max.output value+10~15% of the output span(e.g.,21.6~22.4mA when the output is 4~20mA).
The burnout value may be lowered according to your needs.
(12) Weight
Approx.410g

DESIGNATION ITEM AT ORDER

1. TYPE AND AUXILIARY POWER SUPPLY 2. INPUT 3. OUTPUT
CGP—□ —□ □ —□
AUXILIARY POWER SUPPLY
1 DC 24V
2 AC 100/110V 50/60Hz
3 AC 200/220V 50/60Hz
5 DC 100/110V
6 DC 48V
9 OTHER
TEP.SENSOR INPUT
1 Pt 100Ω 1 0 – 100°C
2 JPt 100Ω 2 0 – 200°C
3 0 – 300°C
4 0 – 400°C
5 -50 ~ 50°C
6 -100 ~ 200°C
9 OTHER 9 OTHER
OUTPUT LOAD RESIS.
DC 0 ~ 100mV 600Ω ~ ∞
DC 0 ~ 1V 600Ω ~ ∞
DC 0 ~ 5V 600Ω ~ ∞
DC 0 ~ 10V 600Ω ~ ∞
DC 1 ~ 5V 600Ω ~ ∞
DC 0 ~ 1mA 0 ~ 10kΩ
DC 0 ~ 10mA 0 ~ 1kΩ
DC 4 ~ 20mA 0 ~ 550Ω
OTHER OUTPUT

 

REQUEST QUOTATION

PAYMENT

payment-methods

 

TOOLS & EQUIPMENT

Lifting
Eagle Clamp | Eagle Jack | Elephant | Endo Kogyo
Japan Clamp | Kanetec | Jung | KITO | Katsuyama Kikai
Kondotec | Miki Netsuren | Sanei Seiki | Taiyo

Hand Tools
Bix | Miyakawa | Nakatani Kikai | Ogura | Osakada Tool
Super Tool | TONE | Yutani

Tape
Kamoi | Kikusui | Misuzu | Nirei | Okamoto | Taiho | Teraoka

Measurement
Hasegawa | Kawaki | Kett | KGK | Line Seiki | Nagano Keiki
Niigata Seiki | Obishi Keiki | RSK | Ryoden Shonan | Sanko
Sanwa Supply | Showa Seisakusho | Showa Sokki
SK Sato | Tokyo Keiso | Tokyo Sokushin

Safety Tools
Fujii Denko | Shigematsu | Titan

Welding
Asahi Weldex | Daihen | Koike | Nissan Tanaka

Drilling
Dijet | Kansai Kogu | Nitto Kohki | Okazaki Seiko | Takeda

Chemical
Cemedine | DaitoNippon Grease | Taseto

Other Tools
Hammer Caster | Kitagawa | Matsuda Seiki | Misuz | Sanritsu
Sanyutec | Shizuoka Seiki | Toyo Kensetsu Kohki | Yamamoto
Yamari

PLANT FACILITIES

Facilities
Acokk | Bunkaboeki | Horiuchi | Konan | Murakoshi
Murakoshi Industries | Nesstech | Nihon Flux | Nikkin Flux
NFK | Omega System | Organo | Taiyo Parker | Toyo Mic

Pump
Dynaflo | Ebara | Honda Kiko | KyowaMusashino
Tsurumi

Valve
Astam | Kyowa Iron | Nachi | Nippon Daiya | Sawada
Wasino Kiki | Yoshitake

Electricity
Arkon | Asahi Bagnal | Gentos | Iwasaki | Kokosha | U_RD

CONSTRUCTION

Concrete Work
Daia | EXEN | Japan Life | Mikasa | Okasan Kiko | Taiheiyo

Railway Work
Kyoei | Sanwa Tekki | Teikoku | Toko

Scaffolding
Bullman | Okabe | Rikiman | Tsugaru

High Tension Bolt
Dong Ah | KPF | Nippon Steel Bolten | Nippon Fastener

Bolt & Nut & Washer
Hard Lock | Kishu Fastener | Matsukin | Mori Kozai
Nakaumi | Naniwa | Ogawa | Otani | Sudo | Toneji

STEEL MATERIAL

Steel & other Material
Dongil | JIS Standard | DSR | Sumitomo Wire | Winoa IKK

Pipe
Benkan

Return Top