TOYO KEIKI GP and HP Series Temperature Transducer

Product Made In Japan
Manufacturer: Toyo Keiki
Model: GP and HP Series

CGP-□: As a temperature sensor the resistance temperature detector is a temperature-DC conversion device.
Generous input specifications. ・From -200℃ to +500℃.
Photo couple provides complete insulation between input and output-the influence of common mode noise is excluded and stable operation is ensured (AC 2000V,1 min.).
Linearizer is standard. ・Linearity below±0.2%.
The influence of connecting cables is excluded. -Resistance temperature detector drives a constant, the type of measurement errors that are caused by the use of a connecting cable do not happen.
It was equipped with a burnout function. ・Sensor circuit failure immediately detected and output.
Plug-in type makes upkeep and configuration changes simple.

Specification

INPUTOUTPUTAUXILIARY POWER SUPPLY
Platinum resistance temperature detector, 3-lead type: Pt100Ω, JPt100Ω. Standard six bands of measured temperature range. Regulated sensor current: DC 2mA8 standard type of output are available. Burnout: UpperAC 100/110V ±10% 50/60Hz approx. 3 VA
AC 200/220V ±10% 50/60Hz approx. 3 VA
DC 24V ±10% approx. 3 W
DC 100/110V ±10% approx. 3.5 W
DC 48V (38-62V) approx. 3 Wtypes are immediately available. For types not listed above contact a company representative.
Available resistance temperature detectors Platinum(Pt, JPt)100Ω (0°C)
-input span of over 50 °C
When resistance temperature detectors not conforming to JISC 1604-1997 are specified please indicate the resistance line curve.
Available with Max. voltage output 10V (600Ω~∞)
Max. current output 20mA (0-550Ω)
The burnout value may be lowered according to your needs.

Connection Diagram

Specified Character

(1) Available resistance temperture detectors
Platinum(Pt,JPt)100Ω -input apan of over 50℃
Platinum(Pt)50Ω -input span of over 100℃
at JIS C 1604-1997(resistance temperature detector)
As well as nickel,platinum-cobalt,and copper resistance tempereture
detectors that conform to JIS C 1604-1997 are also available;
please contact a company representative and explain your need.
Input system 3-lead type (permissible line resistance,200Ω per lead)
(2) Regulated sensor current
DC 2mA
(3) Tolerance
±0.5% of output span.(Ambient temperature 23℃)
(4) Effect of temperature
Within ±0.2% of output span. (For 23℃±10℃ variations)
(5)Effect of auxiliary power supply
Within ±0.1% of output span. (For rated voltage ±10℃ variations)
(6)Effect of load resistance
Within ±0.05% of output span. (For load resistance range)
(7) Output ripple
Within 0.5%p-p of output span.
(8) Response time
Shorter than 0.5sec. (Time to 99% output)
(9) Dielectric strength
2000V AC,1min.(50/60Hz) (Between input,output,auxiliary power supply and external case)
(10) Insulation resistance
Higher than 100MΩ at 500V megger. (Between input,output,auxiliary power supply and external case)
(11) Built-in Functions
Isolation (photo-couple method)-standard
Linearizer (linearity within±0.2%)-standard
Burnuot function-In the standard specification burnout is set for when the following upper limit is exceeded:when the
output value=max.output value+10~15% of the output span(e.g.,21.6~22.4mA when the output is 4~20mA).
The burnout value may be lowered according to your needs.
(12) Weight
Approx.410g

DESIGNATION ITEM AT ORDER

1. TYPE AND AUXILIARY POWER SUPPLY2. INPUT3. OUTPUT
CGP—□—□ □—□
AUXILIARY POWER SUPPLY
1DC 24V
2AC 100/110V 50/60Hz
3AC 200/220V 50/60Hz
5DC 100/110V
6DC 48V
9OTHER
TEP.SENSORINPUT
1Pt 100Ω10 – 100°C
2JPt 100Ω20 – 200°C
30 – 300°C
40 – 400°C
5-50 ~ 50°C
6-100 ~ 200°C
9OTHER9OTHER
OUTPUTLOAD RESIS.
DC 0 ~ 100mV600Ω ~ ∞
DC 0 ~ 1V600Ω ~ ∞
DC 0 ~ 5V600Ω ~ ∞
DC 0 ~ 10V600Ω ~ ∞
DC 1 ~ 5V600Ω ~ ∞
DC 0 ~ 1mA0 ~ 10kΩ
DC 0 ~ 10mA0 ~ 1kΩ
DC 4 ~ 20mA0 ~ 550Ω
OTHER OUTPUT

 