Toyo Keiki
TOYO KEIKI GP and HP Series Voltage Transducer
Product Made In Japan
Manufacturer: Toyo Keiki
Model: GP and HP Series
VGP-□ : Mean value type
VGP-□E : Root-mean-sqare value type
Plug-in type makes upkeep and changes in configuration simple.
Improved reliability and greater compactness through the use of custom ICs.
JIS C 1111 AC/DC transducer 0.5 class.
Specification
INPUT, CONSUMPTION WATT | OUTPUT | AUXILIARY POWER SUPPLY |
---|---|---|
0~150V 50/60Hz 0~300V 50/60Hz approx. 0.5VA |
8 standard types of output are available | AC 100/110V ±10% 50/60Hz approx. 2.5 VA AC 200/220V ±10% 50/60Hz approx. 2.5 VA DC 24V ±10% approx. 2.5 W DC 100/110V (80~143V) ±10% approx. 3 W |
Max. input Available with range 50 ~300V Available with frequency range 45Hz ~10kHz |
Available with Max. voltage output 10V (600 Ω~∞) Max. current output 20mA (0 ~550Ω) |
Types are immediately available. For types not listed above contact a company representative. |
Specific Character
(1) Tolerance
±0.5% of output span. (Ambient temperature 23℃)
(2) Effect of temperature
Within ±0.5% of output span. (For 23℃±10℃ variations)
(3) Effect of auxiliary power supply
Within ±0.25% of output span. (For rated voltage ±10% variations)
(4) Effect of frequency
Within ±0.25% of output span. (For standard frequency ±5% variations)
(5) Effect of load resistance
Within ±0.05% of output span. (For load resistance range)
(6) Output ripple
Within 1%p-p of output span.
(7) Response time
Shorter than 1sec. (Time to 99% output)
(8) Effect of wave from (VGP-□E type only)
Within ±0.5% of output span.
(For third harmonics equivalent to 15% of the basic frequency)
(9) Dielectric strength
2000V AC,1min.(50/60Hz)
(Between input, output, auxiliary power supply and external case)
(10) Insulation resistance
Higher than 100MΩ at 500V megger.
(Between input, output, auxiliary power supply and external case)
(11) Weight
Approx.500g
Connection Diagram
DESIGNATION ITEM AT ORDER
ORDER EXAMPLE
① VGP-1-1-8
② VGP-2E-9-9
INPUT : AC 0~110V, OUTPUT : DC 0~7.5V
※For special specifications please consult company representatives