Toyo Keiki VF-11M Series Wide Angle Meter

Product Made In Japan
Manufacturer: Toyo Keiki
Model: VF-11M Series

Features

1. A long scale meter for indicating wide angles.
2. A stepped scale plate removes any level difference between the scale and the tip of the needle, resulting in accurate readings.
3. Meter that has a bright scale due to the wide-cover lighting surface.
4. It is not affected by steel panels.
5. Can be manufactured with EL board (Electro-Luminescence Board) lighting.
6. The terminal cover is now equipped as standard.
7. It is now compatible with multi-setting set pointer models.

VF-1 1M Series List

Applicable Standards: JIS C 1102-1, 2, 3, 4, 5, 9

Part Name□VF-11MNotes Page
Model NameOperating PrinciplesAccuracy Class
Direct CurrentAmmeterDVF-11MPermanent magnet Moving-coil type1.55
Voltmeter6
Reception Meter5/6
Alternating CurrentAmmeterSVF-11MRectifier type2.57
Voltmeter8
AmmeterSeVF-IIMElectronic device type1.59
Voltmeter10
AmmeterAVF-11MMoving-iron type1.511
Voltmeter12
Reception MeterSVF-11MRectifier type2.57/8
1P WattmeterEVF-11MElectronic device type1.513
3P Wattmeter
3P4W Wattmeter
IP VarmeterRVF-11MElectronic device type1.513
3P Varmeter
3P4W Varmeter
1P Power Factor MeterUVF-11MElectronic device type5.014
3P Balanced Power Rate Meter
3P Unbalanced Power Factor MeterUuVF-11M
3P4W Power Factor Meter
Frequency MetersFVF-11MElectronic device type0.518

Production Standards

☆Can be manufactured to 80×80 (mm) or 120×120 (mm) sizes. Please contact us for more details.

Model Name□VF-11M
Front Dimensions (Horizontal × Vertical) (mm)110×110
JIS Symbol (JISC1103)KW3a
Scale Length (mm)170
Blur Angle237°
Accuracy/ClassRefer to □VF-11 M Series List Table (Upper Table)
Mounting PostureVertical (Other than vertical: Specification required, e.g., /30°)
Recommended No. of Scale DivisionsDivision 35 to division 75
Pointer ShapeVF Standard Pointer (See Next page)
Cover MaterialMethacrylic Resin
Cover Frame Color● Black (Munsell symbol: N-1.5) ● Blue/green color according to specifications (Munsell symbol: 7.5BG 4/1.5)
Base MaterialBody: ABS resin<br>Terminals: PBT resin
Scale PlateAluminum plate with white coating (Scale lines and numbers are black)

Note) See below for details on the recommended scale divisions.
Insulation Test :  Between all circuits in a batch and outer casing …More than 10 MΩ (500V mega tester)
Between current circuit and voltage circuit …More than 5M (at 500V mega)
Voltage Test        Between all measurement circuits in a batch and outer casing, and between current circuit and voltage circuit …maximum usable circuit voltage up to 600V. AC3320V for 5 seconds: CAT III 600V displayed at the bottom right of the scale plate.
If the maximum usable circuit voltage of 600V is exceeded, (2E+1000) V (E: Maximum usable circuit voltage [V])

Operating Environment

Operating Temperature: Limits −10°C to+50°C, Accuracy Assurance Range: +5°C to +40°C
Storage Temperature −20°C to +60°C
Relative Humidity Less than 80%
Operating Environment Indoor
Installation Height 2000m or less (See p.23 for details)

Special Specifications

(Can be manufactured to the following special specification by request.)

  1.  Mounting posture other than vertical (Specification of installation angle required)
  2. With Red Set Pointer Single Setting Type, Multiple Setting Type
    Special Scale: Conversion scale, zero center scale, colored scale, multiple scale, magnifed scale, specific symbol display, scale division increase in lines
  3. Rod pointer (Rod pointer is used for multiple scales.)
  4. EL plate lighting (Color: green or orange) (See below)
  5. Special processing (heat processing, etc.)
  6. Other special specifications

Common Specifications for Meter with EL Plate Lighting

EL plate impressed voltage: 100/110V AC (Please contact us for uses with 200/220V AC and 100/110V DC.)

Outside Dimensions

Note) Accessories are attached externally as shown below for meters with EL plate lighting.
Unmarked items have accessories built-in, and the wiring method is as standard.
See the following pages for details on the outside dimensions of accessories and the wiring methods.

SpecificationsAccessories
AC Voltmeter (Moving-iron Type)M-4 A Series Resistor
WattmeterERG-3 Converter
VarmeterRRG-3 Converter
Power Factor MeterURG-3 Converter <br> Or <br> UuRG-3 Converter