Chino MR5320 Splash Proof Type Two-channel Card Logger

Made in Japan
Manufacturer: Chino Corporation
Model: MR5320

Models

ProductsModelsSpecifications
LoggerMR5320
External SensorMR9301-40°C to 60°C
MR93020°C to100°C
MR930350°C to150°C

Features

MR5320 is 2 ch type card logger of MR5300 and 6,000 data can be store for a channel. Temperature sensor is only built in for channel 1. Data recalling and setting are also available on PC.

  • Number of logging data is 6,000 data each for channels. Measurement interval can be select between 10 to 50sec. and 1 to 60min.
  • ±0.5°C (between -5to 50°C) of high accuracy
  • Logging data can be store even in dead battery.
  • Dust tight and splash proof structure, so it is washable (IP64). Conform to the CE marking safety standard of Europe.
  • Various external sensors: general type, waterproof type, and needle type etc. are available.

Specifications

Measuring Range-40 to 60°C, 0 to 100°C, 50 to 150°C (Ranges are automatically switched by identifying a sensor to be used.)
*Only channel 1 has built-in sensor, measuring range is -20 to 55°C
Accuracy Rating±0.5°C ±1digit (in a range of -5 to 50°C)
*±1.0°C ±1digit of other than above.
Input Point2 points
Number of Logging Data6000 data for each channel
Temperature SensorBuilt-in (channel 1 only)/External sensor switching
*Various external sensors (sold separately): general type, waterproof tube, needle type and surface temperature measuring type etc. are available.
Display Contents
(Each channel)
Current data=Month, day, hour, minute and measuring temperature
Recalling data=Highest, and lowest temperatures in logging period, and average temperature in the logger
Setting parameter=High and low limit alarm set values.
Operation Available in the LoggerDisplay start-up (with auto-off function: Display goes out after one minute when no operation is performed.)
Display content selection (clock setting, logging start/stop, keylock set/release)
*Three function keys of DISP, SEL, and REC.
Communication FunctionCommunication with an exclusive data reader (sold separately) through near-infrared radiation.
Parameter setting, and recalling logger data and logging condition by exclusive analysis software.
Setting in PC
(Dedicated Analysis Software)
Clock, logging start time/stop time (for logging interval unit: min.), measurement/logging interval (10 to 50 sec. or 1 to 60min.), high/low limit alarm temperatures, keylock of the logger, and logging method (automatic stop/endless)
Power SupplyAlkaline battery R03 (AAA), 2pcs
External Dimensions/WeightW54×H110×D20.5mm, approx. 95g (including batteries)

 