Chino, Japan
Chino SE3000 Field Data Scanning Units
Made in Japan
Manufacturer: Chino Corporation
Model: SE3000
Models
Types | Models | |
---|---|---|
Base unit | Without display | SE3100-000 |
With display | SE3101-000 | |
Sub unit for expand input Software KIDS/PASS |
SE3211-000 |
Features
The SE3000 series scanning units connect to a personal computer for data logging. The basic unit with 6 input points can be connected to 7 sub units (6 input points/sub unit) and maximum 48 analog data can be collected. Two software packages, “Data Acquisition Software Package KIDS” for data logging and “Parameter Programming Software Package PASS” for parameter programming are available.
- Expanded type units can expand input points up to 48 points by connecting sub units (6-point input).
- The data acquisition software package “KIDS” and the parameter programming software package “PASS” make data collection easy. “KIDS” can connect up to 5 sets of SE3000 units and manage up to 100 channels.
- Three types of communications interfaces; RS-232C, RS-422A and RS-485 are built-in as standard equipment.
- The SE3000 series scanning units use the international communication protocol MODBUS, allowing them to communicate with MODBUS-equipped units without requiring communication software.
- Input can be selected from universal input options, including 32 types of DC voltage, thermocouples, resistance thermometers, and more.
- Each channel has isolated input, ensuring safe usage.
- The unit works with the BR series paperless graphic recorder as an input extension unit, supporting up to 24 points.
- European safety standards, CE marking conformity.
Specifications
Measuring Point | Base unit 6 points, Sub unit 6 points/ unit *Up to 7 sub units can be connected to 1 base unit (up to 48 points). |
---|---|
Input Type | Universal input 10 DC voltages, 17 thermocouples, 5 resistance thermometers |
Accuracy Rating | ±0.1%±1digit (for DC voltage and general thermocouples) |
Measuring Interval | 1sec. (for 6 points) to 8sec. (for 48 points) |
Burnout | Sensor disconnection judgment function of thermocouples and resistance thermometer inputs is built-in as standard. (Enable/disable selectable) |
Communication Interface | RS-232C, RS-422A, RS-485 (switch selection) *Communication protocol: MODBUS |
Number of Alarms | Up to 4 alarms for each channel |
Alarm Type | High limit, low limit, differential high limit, differential low limit, rate-of-change increase limit , rate-of change decrease limit (No alarm output) |
External Dimensions | Base unit H138×W72×D100mm Sub unit H138×W36×D100mm |
Installation | DIN (35mm) rail mounting |
Rated Power Voltage | 100V-240VAC 50/60Hz |
Display Unit Specifications (option, later installation available)
Display Unit | 7-segment red LED 7 digits |
---|---|
Display Content | Channel number 2 digits, data 5 digits (channel forwarding/fixed) |
Display Update Cycle | 3sec. |