MITSUHASHI CORPORATION
MITSUHASHI PEM-3000 Controller

Manufacturer: MITSUHASHI CORPORATION
Model: PEM-3000
This is a controller for controlling web meandering. It is used in combination with G-series sensors and drive units. It features a color LCD touch panel for universal operability. External interfaces are standard equipment, including input/output terminals for controlling operation mode switching with an external controller, and analog output terminals for monitoring the web status.
Drawing

.① Touch panel
② Operation switches (sheet keys)
③④ Peripheral device connection connectors (sensors, drive units, etc.)
⑤ Power input terminal
⑥ Control output terminals (8 points)
⑦ Control input terminals (8 points)
⑧ Analog output terminals (2 points)
⑨ Pair of panel mounting brackets (included)
*1: Panel cut dimensions *2: Panel surface (allowable thickness: 1≦t≦8mm) *3: For floor mounting bracket (allowable screw insertion length 10mm) *4: For PCM-D40-BP mounting (allowable screw insertion depth 8mm) *5: Connector protective seal – remove when connecting PCM-D40-BP
Features
- The color LCD touch panel allows for intuitive operation.
- It comes standard with terminals for switching operating modes and outputting alarms for external control.
- It comes standard with an analog output for monitoring the web status detected by the sensor.
- The sensors and drive units are connected via connectors, making wiring easy.
- The sensor can connect up to 4 channels and can be used not only for meandering control but also for monitoring web position.
Specification
| power supply | DC24V±20% (Supplied via connector terminal block; connector terminal block model: FKCN2.5/3-STF-5.08, Phoenix Contact) | |
|---|---|---|
| Current consumption | 500mA or less (current consumption of the PEM-3000 unit during operation at a power supply voltage of DC24V) *Power for peripheral devices such as sensors is supplied from the PEM-3000. Please prepare an appropriate power supply taking into account the power capacity of these devices. Also, the total current consumption of devices powered by the PEM-3000 should not exceed 3.5A. | |
| mass | Approximately 1.5kg | |
| Installation environment | Humidity temperature | 0-40℃ |
| Ambient humidity | 80% RH or less (no condensation) | |
| atmosphere | Indoors (out of direct sunlight), well-ventilated. Free from corrosive gases, flammable gases, oil mist, and dust. | |
| others | Please avoid installing the device in locations with high vibration levels. | |
| Connected devices | sensor | Up to four PSM series devices can be connected. Single: Detects web edge or line mark. Centering: Detects both web edges. |
| drive unit | • Actuators: PDM series • Roll guiders: PGM series • Other DC motor-equipped drive units: PD, PG, MR series (drive units with a rated current of 2.5A or less) Note: When using a DC motor-equipped drive unit, the DC motor driver PCM-D40 is required. | |
| option | • Expansion I/O Module: PXM-100 with 10 inputs (reference position SET, mode selection (AUTO/MAN/CENT), drive unit operation, bank selection, mode interrupt) and 10 outputs (sensor OK, mode status (AUTO/MAN/CENT), drive unit stroke end, drive unit center, comparator (upper/lower limit), bank switching response) • Remote Box: PTM-100 | |
| Display | 5.7-inch TFT color display with touch panel | |
| Display language | Japanese, English, Chinese, Korean | |
| operation | Sheet keys and touch panel | |
| External control terminal | • 8 Inputs: Reference position SET, Mode selection (AUTO/MAN/CENT), Bank selection, Drive unit operation, Mode interrupt. *Only one of Bank selection or Drive unit operation can be used (select one via parameter). • 8 Outputs: Sensor status, Mode status (AUTO/MAN/CENT), Comparator output, NG, System run, Drive unit center. • 2 Analog Outputs: Select from Control sensor output, Comparator sensor output, Drive unit operating speed via parameter (connected via connector terminal block, Connector terminal block model: FMC1.5/4-STF-3.5, Phoenix Contact). | |
Note: A dedicated CAN bus cable and branch connector are required to connect the PEM-3000 to sensors, drive units, and other optional equipment. Please select the appropriate cable and connector for the equipment you are connecting. The above cables and connectors are available from our company (sold separately).