| Model | SMF-PVDF-V40 | |
| Membrane Material | PVDF | |
| Nominal Pore Size | 0.05μm | |
| Membrane Area | 40m2 | |
| Filtration Method | External Pressure Full-Flow Filtration Method /Cross-Flow Method | |
| Membrane Shape | Hollow Fiber (Capillary Type)) | |
| Housing Material | U-PVC | |
| Modules Dimensions | φ225mm × H1850mm | |
| Modules Weight | (Dry)45kg (Wet)90kg | |
| Connection Specifications | 50A Housing Pipe Fitting | |
| Operating Conditions | Maximum Operating Pressure | 0.3MPa |
| Maximum Membrane Differential Pressure | 0.2MPa | |
| Water Temperature | 5~40°C | |
| pH | During Operation : 3~11 During Chemical Cleaning : 2~12 | |
| Design Filtration Capacity*2 (m3/h) Water Temperature of 25°C | Water Purification System | 2.8~5.5m3/h |
| Seawater System*2 | 3.7~5.1m3/h | |
| Sewage System | 2.0~3.5 m3/h | |
Tohkemy Corporation
Tohkemy SMF Vessel System Water Treatment Systems


Manufacturer: Tohkemy Corporation
Model: SMF Vessel System
Features
Achieves high flux through special membrane technology
Clear water flux: 6.8 m³/(m²·d) (0.2 MPa, 25℃)
High flux enables large-capacity water purification.
Excellent cleaning capability achieved through combined water and air use
Effectively removes turbidity by combining backwashing with permeate water and bubbling.
Capable of removing Cryptosporidium and Legionella
With a nominal pore size of 0.05 µm, it can remove Cryptosporidium, a major threat to drinking water,
and Legionella, a major threat to hot bath facilities and cooling towers.
Applications
Decontamination and infection control of water and beverage facilities
Advanced treatment of tap water
Pretreatment of RO membrane equipment
Aseptic seawater production* (Fish processing)
* Pretreatment may be required.
Product Specifications
*1 Filtration capacity varies depending on operating conditions such as raw water quality, water temperature, supply pressure, and backwash conditions. This value is a guideline.
Please consult our sales representative during design.
Accurate design filtration capacity, backwash conditions, and other operating parameters can be determined by conducting membrane filtration tests using actual raw water. Membrane filtration tests are available for a fee.
*2 This refers to seawater after pretreatment.
* When placing an order, please consult with our sales representative to determine the number of vessels and operating conditions based on the required treated water volume.
Unit Specifications

Flow Sheet
Dimentional Outline Drawing


Related Products
-

Tohkemy Beta B Chemical Pump
-

Tohkemy Flow monitor Pump Accessories
-

Tohkemy Air Chamber Pump Accessories
-

Tohkemy Actifiber R Ultra Precision Membrane And Fiber Filter Media
-

Tohkemy Color/Humic Substances Removal Water Treatment Systems
-

Tohkemy Gravity Backwashing Filtration System Water Treatment Systems