Japan, Kyowa Electronic Instruments Co., Ltd.
Kyowa PSS-05KAE PSS Miniature Pressure Sensor
Made in Japan
Manufacturer: Kyowa Electronic Instruments Co., Ltd.
Model: PSS-05KAE
The PSS is a miniature pressure sensor with a strain gauge bridge inside. Thin-film strain gages are directly formed on the diaphragm.
Features
Ultra-thin
Installed by adhesives
Suitable for distributed pressure measurement by using multiple units
Specifications
Performance
Rated Capacity | 50 kPa |
---|---|
Nonlinearity | Within ±1% RO |
Hysteresis | Within ±1% RO |
Repeatability | 0.5% or less |
Rated Output | 1 mV/V or more Note: Rated output is sorted into one of the classes divided by every 2% difference in output value. Since the rated output stated in the Test Data The sheet is the centre value of the class, it may have a maximum error of ±1%. |
Cable Direction to Sensing Surface | Horizontal |
Environmental Characteristics
Safe Temperature | -20 to 70ºC (Non-condensing) |
---|---|
Compensated Temperature | 0 to 50ºC (Non-condensing) |
Temperature Effect on Zero | Within ±0.8% RO/ºC |
Temperature Effect on Output | Within ±0.3%/ºC |
Electrical Characteristics
Safe Excitation | 4 V AC or DC |
---|---|
Recommended Excitation | 1 to 2 V AC or DC |
Input Resistance | 350 to 1000 Ω |
Output Resistance | 350 to 1000 Ω |
Initial Unbalance | Within 2.5 mV/V (5000 ×10-6 strain) |
Cable | Polyurethane coated copper wires, 0.08 mm diameter by 5 cm long, bared at the tip |
Mechanical Properties
Safe Overloads | 150% |
---|---|
Natural Frequencies | Approx. 18 kHz |
Weight | Approx. 0.15 g (Excluding cable) |
Dedicated Adhesive | RC-19 (Request the RC-19 when ordering the transducer. Cost option) |
Dimensions
To Ensure Safe Usage
High-carrier-based dynamic strain amplifier DPM-912,913 or 952 may not satisfy the specified rated output in a rare case.
Use dynamic strain amplifier DPM-911,951, signal conditioner CDV-900A or request us to
calibrate the transducer in combination with the strain amplifier.
Remarks
(Note 1) Copper alloy is used for the liquid-contacting part.
Avoid measuring corrosive liquid or gas.
(Note 2) An epoxy adhesive is used to assemble the liquid-contacting part.
Therefore, avoid using the sensor to measure organic solvents (Toluene, ketone, etc.)
(Note 3) It should not be used under high temperature and high humidity environments for a long time.
(Note 4) It should not be used underwater.
Related Products
-
Kitz 10UPAJ,10UPAJM Stainless & High Alloy 10K Jacketed Globe Valve
-
Satuma Denki PB3-PL3-Series Pad-type Disk Brakes AC-operated DC Electromagnetic System
-
Hammer Caster 502BPS-CU Big Size Urethane Thermosetting Wheel
-
Kondotec C type Separator
-
YOSHITAKE TS-1HA Radiator Trap
-
Kanetec KM-S9/S12 SIMPLE HEXAGONAL HOLDER