Manufacturer: Hasegawa Electric
Model: HPI-A6/S6/S20
HPI-A6: AC3kV~7kV
HPI-A6F: AC3.3kV~6.6kV
*Voltage detection terminal: 6.6kV/22kV/33kV
HPI-S6: AC6.6kVHPI-S11:AC11kV
HPI-S20: AC22kV~34.5kV
Detector pairs insulated with optical fiber
Features of HPI-A6/S6/S20
●Multi-functional phase tester Voltage Detection by single detector use, Phase detection/phase sequence check with pair detector use.
●Measurement is possible on the insulated wire sheathTesting operation is possible through voltage detection terminals or on the wire insulation. *Can not be used on the shielded cable.
●Indication for phase sequence In-phase / different phase, and phase sequences are indicated by sound and light indications.
Dimensions
Specification
Model | HPI-A6 | HPI-A6F | HPI-S6 | HPI-S11 | HPI-S20 |
Working voltage range |
3kV”-‘7kV |
3.3kV~6.6kV
|
6.6kV |
11kV
|
22kV”-’34.SkV |
Target | For Cubicles | For under round cubicle | For overhead lines | ||
Frequency | 50/60Hz | ||||
Insulation resistance | 2000MQ or more | ||||
Dielectric strength | 20kV, lmin | 75kV, 1min | |||
Operating temperature range | Operating temperature range -10℃~+40℃
|
||||
Indication of operation Light |
It shall be able to confirm luminance of 8,000lux. | ||||
Indication of operation Sound |
50dB or more at a distance of 1m from the sound-generating part[intermittent sound generation] | ||||
Phase test function | Detection of in-phase or different phase of 120° | ||||
Phase sequence function | Detection of advance or delay of 120° | ||||
Possible distance of phase test |
Distance between transmitter and receiver, with standard optical cable:6m {3mx2} | ||||
Possible distance of phase test |
It can be used at up to 30m with the optional cable. | ||||
Battery | R1( 1. SV), each 2pcs [for transmitter and receiver] | ||||
Case | Attache case | Bag for housing |
■How to use
1. Phase checking
By setting the reception side[P1] as a reference, check
the transmission side[P2] corresponding to each phase,
If there are no sound and light indications, it is “Different
phase”.
2. Rotation checking
When detectors contact two out of three phases, and if there are no sound and light indications, at the reception side[P1], this indicates “positive rotation”, and if there are, this indicates “inverse rotation”.
Other items of Hasegawa Electric
Request the quotation for Hasegawa Electric