Jasco Detector High-performance Liquid Chromatograph EXTREMA

Made in Japan
Manufacturer: Jasco
Model: Detector  : UV-4070, UV-4075, MD-4010, MD-4015, MD-4017, RI-4030, RI-4035, FP-4020, FP-4025, CD-4095, OR-4090

EXTREMA is a high performance liquid chromatograph (HPLC) that brings together the best of JASCO’s technology. You can build the optimal system for your purpose from a variety of units, including UHPLC, RHPLC (Rapid Separation HPLC), semi-preparative pumps, and high-sensitivity detectors. The chromatography data system, ChromNAV, renowned for its operability and processing functions, now offers enhanced functionality and user-friendliness with its upgrade to Ver. 2.0. This version includes various improvements, making it more efficient and intuitive for users.

System lineup

There are three types in the lineup: HPLC/RHPLC, UHPLC, and Prep-HPLC. Many units are available, and you can build the optimal system by combining units suited to your purpose.

High-performance liquid chromatograph system lineup

From the left: HPLC/RHPLC, UHPLC, Prep-HPLC

UHPLC

Ultra High Performance Liquid Chromatography (UHPLC) uses columns packed with ultrafine particles of 2µm or less, enabling separation at high pressure (up to 130 MPa). This method allows for high-speed separation while maintaining high separation efficiency. Compared to conventional HPLC, UHPLC significantly shortens analysis time, reducing it to just 1/5 to 1/10 of the usual duration. Additionally, it minimizes the amount of mobile phase solvent used, cutting it down to nearly 1/10, thus enhancing both efficiency and sustainability.

HPLC/RHPLC

Rapid Separation HPLC (RHPLC) provides a high-speed analysis method that spans the range from conventional HPLC to some UHPLC applications. This analytical system utilizes fully porous packed columns with particle sizes of 2 to 3 µm and core-shell columns. Moreover, it supports measurements in the medium pressure range (30 to 70 MPa), positioning itself as the future standard analytical method.

Prep-HPLC

Preparative High Performance Liquid Chromatography (Prep-HPLC) focuses on isolating and purifying target compounds with high purity from synthetic products and natural substances. EXTREMA, equipped with a semi-preparative pump, enables its use as a semi-preparative high performance liquid chromatograph (Prep-HPLC). Additionally, it facilitates micro- and ultra-micro-preparative separations when integrated with an RHPLC or UHPLC system.

Unit Lineup

One can construct a system by combining a wide range of units according to the intended purpose, allowing for flexibility and customization.

HPLC RHPLC UHPLC Prep-HPLC
pump PU-4185, PU-4180, PU-4085i, PU-4080i, PU-4085B PU-4285, PU-4285B PU-4086, PU-4087, PU-4086B
Detector UV-4070, UV-4075, MD-4010, MD-4015, MD-4017, RI-4030, RI-4035, FP-4020, FP-4025, CD-4095, OR-4090
Autosampler AS-4050, AS-4050i AS-4150 AS-4250 AS-4058
Column Oven CO-4060, CO-4065, CO-4061, CO-4062, RO-4068

Hardware

UV-4070/4075 UV-Visible Absorbance Detector

The UV-Vis absorbance detector is equipped with a Czerny-Turner monochromator with excellent optical characteristics. By improving stability through measures such as reducing drift caused by temperature control of the cell body, a noise level of ±0.2×10 −5 AU has been achieved.

The UV-4070 can measure from 190 to 900 nm, and the UV-4075 can measure from 190 to 600 nm.

The UV-4070/4075 supports simultaneous two-wavelength detection and spectrum auto-scan.

HPLC UV detector UV-4070

Fluorescence detector FP-4020/4025

The fluorescence detector has been designed to be highly sensitive, with the FP-4020 achieving the world’s highest level of S/N of over 2300 (Raman scattering of water), and the FP-4025 achieving S/N of over 1400. It supports simultaneous detection of two wavelengths, changing of excitation and fluorescence wavelengths for each peak by time program, and spectrum autoscan. It supports high-speed data acquisition and can be used as a detector for UHPLC and RHPLC.

HPLC Fluorescence Detector FP-4020

Refractive index detector RI-4030 / 4035

The optical system is housed in a precisely temperature-controlled block to shut out disturbances caused by external temperature.

By rearranging the piping, the RI-4030 can be used in two different modes: analytical mode and preparative mode. In preparative mode, it supports high flow rates of up to 120 mL/min.

The RI-4035 is equipped with a semi-micro cell that supports semi-micro analysis, and can be used for semi-micro GPC analysis using fine particle GPC columns. It also supports high speed data acquisition.

RI-4030 HPLC Refractive Index Detector

Circular dichroism detector CD-4095

The CD-4095 is a unique detector developed by JASCO, a leading manufacturer of circular dichroism spectrometers. It can detect optically active substances with circular dichroism with high sensitivity and selectivity. It supports spectrum autoscan and can measure the CD spectrum of eluted substances.

HPLC Circular Dichroism Detector CD-4095

Optical rotation detector OR-4090

The optical rotation detector measures the tilt of the polarization plane caused by optical isomers, so it can measure samples that do not absorb light in the UV-visible region. It covers a wide range from 350 to 900 nm, so it can be used with a variety of samples.

HPLC Optical Rotation Detector OR-4090

Software Features

System control using ChromNAV Ver.2

ChromNAV Ver.2 is an easy-to-use chromatography data system. It fully utilizes the performance of EXTREMA, from controlling the entire system to analyzing measurement results and managing data.
ChromNAV CFR Ver.2 with enhanced data integrity is also available

HPLC Systems

Data acquisition and analysis using ChromNAV Lite

ChromNAV Lite is a PC integrator with excellent operability. It is specialized for recording and analysis functions, and has high cost performance and a simple and easy-to-understand user interface.

 Detector

Specification

UV-Visible Absorbance Detector

Model name
UV-4070 / UV-4075
light source D2 lamp + WI lamp (UV-4070) D2 lamp (UV-4075 )
Measurement Wavelength Range 190-900nm (UV-4070)
190-600nm (UV-4075)
Monochromator Czerny-Turner type
Noise Level ±0.2 × 10−5 AU (250 nm, 1.5 sec)
Data Output Rate Up to 100Hz
Spectral measurement
(on-flow measurement)
200-900nm (D2 & WI), 200-370nm (D2 ) , 371-900nm (WI) (UV-4070)
200-600nm (D2 ) (UV-4075), fixed measurement range
Simultaneous measurement of two wavelengths Any two wavelengths within 190-370nm, 371-700nm, 701-900nm (UV-4070) Any
two wavelengths within 190-370nm, 371-600nm (UV-4075)

Fluorescence detector

Model name
FP-4020 (high performance model) / FP-4025 (general purpose model)
light source Xe Lamp
Wavelength range 200-700nm (option: 200-900nm (fluorescence side))
Spectral Bandwidth Excitation side: 20 nm, Fluorescence side: 20, 40 nm selection
Detection sensitivity Raman peak scattering of water S/N>2300 (FP-4020), S/N>1400 (FP-4025)
(excitation wavelength 350 nm)
Data Output Rate Up to 100Hz
Spectral measurements Excitation, fluorescence spectrum measurement, output, difference spectrum output
Simultaneous measurement of two wavelengths Simultaneous measurement of two sets of excitation fluorescence wavelengths (maximum wavelength difference of the two sets of excitation fluorescence is within 200 nm)

Refractive Index Detector

Model name
RI-4030 RI-4035
Measurement method Deflection type
Refractive Index Range 1.00 to 1.75
Noise Level 0.20 × 10 −8 RIU or less (HIGH, STD) (H 2 O enclosed) 0.50 × 10 −8 RIU or less (HIGH, STD) (H 2 O enclosed)
Maximum flow rate 10mL/min (Low Flow Rate piping)
120mL/min (High Flow Rate piping) ( H2O )
1.2mL/min ( H2O )

PDA detector

Model name
MD-4010 MD-4015 MD-4017
light source D2 lamp & WI lamp D2 Lamp D2 Lamp
Measurement Wavelength Range 190-900nm 200-600nm 200-400nm
Number of detector elements 1024ch 512ch 512ch
Slit Width 1, 4, 8nm 4nm 4nm
Data Acquisition Speed Maximum 100spectra/sec (all wavelength range) Maximum 100spectra/sec (all wavelength range) Maximum 20spectra/sec (all wavelength range)
Noise Level ±0.3 × 10−5 AU (specified conditions) ±0.3 × 10−5 AU (specified conditions) ±0.7 × 10−5 AU (specified conditions)

Circular dichroism detector

Model name
CD-4095
light source 150W Hg-Xe lamp
Polarizer Glan Taylor Prism
Phase Modulation PEM (Photoelastic Modulator) method
Measurement Wavelength Range 220-460nm
Noise Level 0.04mdeg (specified conditions)
Data Output Rate Up to 100Hz
Spectral measurements 220-460nm

Optical Rotation Detector

Model name
OR-4090
light source 150W Hg-Xe lamp
Photometry Polarizer/analyzer-based Faraday cell optical modulation method
noise 0.02mdeg (specified conditions) *
Data Output Rate Up to 100Hz

* Calibrated so that the sucrose optical rotation in the visible light region coincides with the NaD line sucrose optical rotation. Noise and drift values ​​are converted to a 10 mm path length.

REQUEST QUOTATION

PAYMENT

payment-methods

 

TOOLS & EQUIPMENT

Lifting
Eagle Clamp | Eagle Jack | Elephant | Endo Kogyo
Japan Clamp | Kanetec | Jung | KITO | Katsuyama Kikai
Kondotec | Miki Netsuren | Sanei Seiki | Taiyo

Hand Tools
Bix | Miyakawa | Nakatani Kikai | Ogura | Osakada Tool
Super Tool | TONE | Yutani

Tape
Kamoi | Kikusui | Misuzu | Nirei | Okamoto | Taiho | Teraoka

Measurement
Hasegawa | Kawaki | Kett | KGK | Line Seiki | Nagano Keiki
Niigata Seiki | Obishi Keiki | RSK | Ryoden Shonan | Sanko
Sanwa Supply | Showa Seisakusho | Showa Sokki
SK Sato | Tokyo Keiso | Tokyo Sokushin

Safety Tools
Fujii Denko | Shigematsu | Titan

Welding
Asahi Weldex | Daihen | Koike | Nissan Tanaka

Drilling
Dijet | Kansai Kogu | Nitto Kohki | Okazaki Seiko | Takeda

Chemical
Cemedine | DaitoNippon Grease | Taseto

Other Tools
Hammer Caster | Kitagawa | Matsuda Seiki | Misuz | Sanritsu
Sanyutec | Shizuoka Seiki | Toyo Kensetsu Kohki | Yamamoto
Yamari

PLANT FACILITIES

Facilities
Acokk | Bunkaboeki | Horiuchi | Konan | Murakoshi
Murakoshi Industries | Nesstech | Nihon Flux | Nikkin Flux
NFK | Omega System | Organo | Taiyo Parker | Toyo Mic

Pump
Dynaflo | Ebara | Honda Kiko | KyowaMusashino
Tsurumi

Valve
Astam | Kyowa Iron | Nachi | Nippon Daiya | Sawada
Wasino Kiki | Yoshitake

Electricity
Arkon | Asahi Bagnal | Gentos | Iwasaki | Kokosha | U_RD

CONSTRUCTION

Concrete Work
Daia | EXEN | Japan Life | Mikasa | Okasan Kiko | Taiheiyo

Railway Work
Kyoei | Sanwa Tekki | Teikoku | Toko

Scaffolding
Bullman | Okabe | Rikiman | Tsugaru

High Tension Bolt
Dong Ah | KPF | Nippon Steel Bolten | Nippon Fastener

Bolt & Nut & Washer
Hard Lock | Kishu Fastener | Matsukin | Mori Kozai
Nakaumi | Naniwa | Ogawa | Otani | Sudo | Toneji

STEEL MATERIAL

Steel & other Material
Dongil | JIS Standard | DSR | Sumitomo Wire | Winoa IKK

Pipe
Benkan

Return Top