Jasco FTIR 4X Fourier Transform Infrared Spectrophotometer (FTIR)

Made in Japan
Manufacturer: Jasco
Model: FTIR 4X

Features of the Fourier transform infrared spectrophotometer FT/IR-4X

Research grade, yet downsized

Footprint fits on two A3 sheets of paper

Compared to previous models (FT/IR-4000 series), the installation area has been reduced by approximately 40%.
FTIR 4X

High S/N ratio, high resolution, and high wavenumber accuracy in a compact body

The 24-bit A/D converter, low-noise electrical system, high-brightness light source, high-performance detector, and high-throughput optical system provide a high S/N ratio of 35,000:1, enabling highly sensitive measurements of small samples and microscopic measurements.

Food packaging wrap coating (ATR measurement) and φ0.5 mm PS film (transmission measurement)

The maximum resolution is 0.4 cm -1 , and the vibrational spectrum of gas can be measured. The automatic aperture is set to the optimum aperture size according to the resolution.

Transmission spectrum of CH 4 (methane) gas (using a 10 cm gas cell)

The semiconductor laser realizes a long life and contributes to the miniaturization of the equipment. The laser is oscillated with high precision using the XLD method, achieving a wavenumber precision of 0.0005 cm -1 , equivalent to that of a He-Ne laser.

PS film data (10 measurements stacked) and PS peak position stability (10 measurements stacked)

Pursuing robustness and expandability so you can use it for a long time with peace of mind

Maintenance-free structure

The sealed interferometer, known for its robust performance, effectively protects humidity-sensitive optical elements with high sealing capabilities. It eliminates the need for overnight operation or frequent desiccant replacement. A built-in temperature and humidity sensor continuously monitors conditions, ensuring reliable use. The interferometer window plate, made of KRS-5, offers excellent moisture resistance.

The sampling laser, utilizing a long-life semiconductor laser, ensures dependable long-term use. The interferometer mirror employs a corner cube mirror, which cancels disturbances in real time.

     

Closed-type interferometer                                        Semiconductor laser                                        Corner Cube Mirror

Self-diagnosis function

The self-diagnosis function checks the device’s status at startup. If there is an abnormality, you will know immediately. The results are automatically recorded and you can track changes over time, so if a problem occurs with the data, you can go back and check it.

Outstanding expandability for a wide range of applications

Detectors can be added

It is possible to add additional detectors such as MCT detectors and InGaAs detectors. Users can replace the additional detectors.

MCT installation example                                                       RAS measurements of PMMA thin films using an MCT detector

Rapid scan measurement

It supports rapid scan measurements at 80 spectra/sec (16 cm -1 resolution), allowing you to capture fast reaction processes with precision.
Reaction process of UV curing resin (using MCT detector)            Change in 1427 cm peak

Expandable measurement wavenumber range

In addition to the standard mid-infrared, options are available to change to near-mid-infrared (11,500 to 375 cm -1 ) or mid-far-infrared (6,000 to 220 cm -1 or 6,000 to 50 cm -1 ) by replacing the light source, beam splitter, window, and detector.

Mid-far infrared measurement of PVDF

Pursuing software that can perform the same analyses as experts

Spectrum Manager Ver.2.5 is equipped with a navigation function that allows even those who are unfamiliar with infrared analysis to perform measurements in the same way as experts. Once the conditions set using the navigation function are registered in a method, measurement can be started simply by calling up the method.

Navigation Features

By simply following the navigation, you can set the measurement conditions appropriate for your measurement purpose.
FTIR 4X

Method Function

If you register frequently used measurement conditions as a method, you can perform measurements simply by selecting the desired method next time.

Registering with a method

Specification

FT/IR-4X

Model name
FT/IR-4X
Measurement wave number range7800 to 350 cm −1
Extended measurement wavenumber range11500 to 375 cm −1 , 6000 to 220 cm −1 , 6000 to 50 cm −1
Disassembly0.4 cm −1 , 0.5 cm −1 , 1.0 cm −1 , 2.0 cm −1 , 4.0 cm −1 , 8.0 cm −1 , 16.0 cm −1
Interferometer45° incidence Michelson interferometer
Ge/KBr Beam splitter, corner cube mirror
Auto alignment mechanism, DSP control, sealed type (KRS-5 window plate)
light sourceHigh brightness ceramic light source
DetectorDLATGS (with temperature control)
Signal to noise ratio35000:1
Standard ProgramJASCO Spectrum Manager Ver.2.5
Dimensions & Weight386(W) x 479(D) x 254(H) mm (main unit only), 18 kg (main unit only)
Power requirementsAC100V 50/60Hz 100VA (main unit only)