Japan, KETT ELECTRIC LABORATORY, Measurement, Moisture Analyzer
KETT ELECTRIC LABORATORY FD-720 Infrared Moisture Analyzer
Product Made in Japan
Manufacturer: KETT ELECTRIC LABORATORY
Model: FD-720
Features of FD-720
Mid-class model of infrared moisture analyzer
Minimum moisture content display 0.01%, weight display 1mg
Features infrared quartz heater that achieves high drying-efficiency
Six types of measurement modes
Specification
Measurement Method | Heat drying and weight loss |
---|---|
Sample mass | 0.5~120g |
Measurement subject | Moisture / Solid content / Weight |
Reproducibility (Standard deviation) | Sample with a weight of 5g or higher: 0.05% Sample with a weight of 10g or higher: 0.02% |
Measurement range | 0~100% (wet base, solids),0~500%(dry base) |
Resolution | 0.01% , 1mg |
Temperature range | 30~180°C |
Measurement modes | Automatic operation mode: Timed operation mode (1~240min or continuous): High-speed drying mode: Low-speed drying mode: Stepped drying mode (max of 5 steps): Predictive measuring mode |
External output | RS-232C interface |
Environmental conditions | Temperature 5~40°C, Humidity: max of 85%RH Pollution degree 2, Altitude up to 2000m |
Sample dish | SUS (diameter 130mm, depth 13mm ) |
Heat source | Mid-wave infrared quartz heater (200Wx2) |
Power supply | AC100~120V / 220~240V (50/60Hz) |
Power consumption | max 900W |
Size and Weight | 220(W)x415(D)x190(H), 4.5kg ,Shipment 310(W)x580(D)x400(H), 10kg |
Accessories | Sample dish 2 pcs, Sample dish handler 2 pcs, Windshield, Sample dish tray, Spoon and spatula set, Spare fuses(T8A 250V) 2 pcs, Power cord, Aluminum sheets(20 pcs)x2, Operating manual |
Options | Printer set( Printer VZ-330), Datalogger software “FDL-02”, Radiation thermometer calibration kit GF-100 |
Options
Example of VZ-330 output:
FW-100 can be installed within t h e F D -720 to reduce errors caused by the influence of external airflow on the high precision balance. Further, since a deodorizing filter is provided on its upper portion, it is also possible to reduce odors created during heat drying.
By connecting the FD-720 to a PC in which the “Datalogger software FDL-01” and MS Excel® are installed, it is possible to transfer and save the measurement data to the PC in real-time. Also, it is possible to display the recorded measurement data graphically, so that the moisture and temperature condition changes can be visually confirmed. The graph can show the moisture, thermistor (T1) temperature, and radiation thermometer (T2) temperature.
Different forms of samples can be measured
Most samples that vaporize only moisture and cause no hazardous reaction under heating can be measured.
Related Products
-
Kitz C-UTGE Type C Pneumatic Actuators/Class 10K Stainless Steel Ball Valves, with Gland
-
OSC53CU106 Presso-Therapy System
-
KONAN QEV3/QEV3S Quick-Release Valve
-
Shinano SI-1556SR 3/4″ 1/2″ Impact Wrench with 6″Extended Anvil Standard Air Tools
-
Organo FIBAX Pre-Treatment System, A Long Fiber Type High-Speed Turbidity Removal System For Drinking Water
-
Eagle Jack (Konno Corporation) G-160 Standard Toe Jack Share