Koganei Solenoid Valves JC Series

Manufacturer: KOGANEI CORPORATION

Features

The solenoid valve delivers thin, compact performance, making it ideal for space-restricted equipment designs. First, its 10 mm (0.394 in.) width and 65.4 mm (2.575 in.) length create a streamlined profile that saves valuable installation space. Additionally, the valve supplies a large flow rate thanks to its compact yet efficient body. With a sonic conductance of C = 0.6 dm³/(s·bar) and an effective area of S = 3.0 mm² (Cv: 0.17), it reliably supports cylinder bores up to φ40.

The valve also ensures a quick response, improving overall system productivity. When energized, it responds in 6 ms or less, and when de-energized, it reacts in 7 ms or less, especially in quick-response single-solenoid models. Furthermore, it maintains lower power consumption, using only 0.55 W for standard types or 0.15 W for low-current types, which helps reduce operating costs.

This compact valve series also improves reliability. The upgraded solenoid and stem structure enhances durability, responsiveness, and long-term performance. Moreover, its environmental protection features, such as moisture-resistant grommet-type valves, ensure dependable operation even in challenging conditions.

Users can also choose optional features to improve installation flexibility. For example, the A-type manifold (base-piping style) mounts easily on a DIN rail, simplifying equipment setup and future maintenance.

Specifications

Basic modelFor direct piping,
F type manifolds
For base piping,
A type manifolds
JC10□F1JC10□F2JC10□F3JC10□F4JC10□F5JC10□F6JC10□F7JC10□F8JC10□F9
JC10□A1JC10□A2JC10□A3JC10□A4JC10□A5JC10□A6JC10□A7JC10□A8JC10□A9
MediaAir
Operation typeInternal pilot type
Flow rate characteristics
(Note 1)
Sonic conductance C (dm³/s·bar)0.6
Port size (Note 2)M5 × 0.8
LubricationNot required
Operating pressure range
MPa (kgf/cm²)[psi]
0.2〜0.7 (2〜7.1) [29〜102]0.25〜0.7 (2.5〜7.1) [36〜102]
Proof pressure
MPa (kgf/cm²)[psi]
1.05 (10.7) [152]
Response time (Note 3)
ON/OFF ms
Standard type:
10/20 or below
12 or below
Low current type (L):
10/50 or below
10/30 or below
Quick response type (S):
6/7 or below
6/12 or below
Maximum operating frequency
Hz
Low current type (L): 55
Quick response type (S): 20
Minimum time to energize for self holding (Note 4)
ms
50
Operating temperature range
(atmosphere and media) °C [°F]
5〜50 [41〜122]
Shock resistance
m/s² (G)
1373 (140)
(Axial direction 294.2 (30))
1373 (140)
(Axial direction 147.1 (15))
1373 (140) (Axial direction 196.0 (20))
Mounting directionAny

 